OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340344480 0215000 2015-02-10 544 PARK AVENUE, BROOKLYN, NY, 11205
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2015-02-10
Case Closed 2018-04-10

Related Activity

Type Complaint
Activity Nr 923815
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-08-03
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., an employee who was required to wear a half-face 3M respirator while spray finishing was exposed to respiratory hazards because a written respiratory protection program had not been implemented at the worksite. (b) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who were required to wear N-95 respirators while refinishing furniture with the methylene chloride-containing chemical "z-best remover" were exposed to respiratory hazards because a written respiratory protection program had not been implemented at the worksite.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 D01 I
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., employees whowere required to wear N-95 respirators while refinishing furniture with the methylene chloride-containing chemical "z-best remover" were exposed to respiratory hazards because the employer had not selected an appropriate respirator based upon the hazards of the chemical.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., an employee who was required to wear a half-face 3M respirator while spray finishing was exposed to respiratory hazards because a medical evaluation of the employee had not been done prior to the wearing of the respirator.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 F01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) On or about 2/10/2015 at Diamond Furniture Services Inc., an employee who was required to wear a half-face 3M respirator while spray finishing was exposed to respiratory hazards because fit testing had not been conducted.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100138 B
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 2800.0
Initial Penalty 2800.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(b): The employer did not base the selection of the appropriate hand protection on an evaluation of the performance characteristics of the hand protection relative to the task(s) to be performed, conditions present, duration of use, and the hazards and potential hazards identified: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards because the employer provided thin, green, Shannon brand, vinyl gloves which ended at the wrist. These gloves were permeable to methylene chloride.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19101052 D01 I A
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(d)(1)(i)(A): The employer did not determine each employee's exposure by taking a personal breathing zone air sample of each employee's exposure: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards because the employer failed to determine each employee's personal exposure through a breathing zone air sample.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19101052 L01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(l)(1): The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards because the employer failed to train employees on the hazards of methylene chloride.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19101052 I02
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1052(i)(2): It was reasonably foreseeable that an employee's eyes may contact solutions containing 0.1 percent or greater methylene chloride and the employer did not provide appropriate eyewash facilities within the immediate work area for emergency use: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards because the employer failed to provide an eyewash. Employees working with this 70-90% methylene chloride chemical solution could foreseeably have eye contact during furniture refinishing.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2015-08-03
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., a spray finisher was exposed to chemical hazards while applying Becker Acroma Bernyl Intro 90/90 Gloss. The employer had not instituted a written hazard communication program. (b) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards. The employer had not instituted a written hazard communication program.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): (a) On or about 2/10/2015 at Diamond Furniture Services Inc., a spray finisher was exposed to chemical hazards while applying Becker Acroma Bernyl Intro 90/90 Gloss. The employer did not maintain onsite or ensure access to a safety data sheet for this chemical. (b) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards. The employer did not maintain onsite or ensure access to a safety data sheet for this chemical.
Citation ID 01004C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-08-03
Nr Instances 2
Nr Exposed 3
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., a spray finisher was exposed to chemical hazards while applying Becker Acroma Bernyl Intro 90/90 Gloss. The employer had not trained the employee on the hazards of the chemical. (b) On or about 2/10/2015 at Diamond Furniture Services Inc., employees who refinished furniture with the methylene chloride-containing chemical "z-best remover" were exposed to chemical hazards. The employer had not trained the employee on the hazards of the chemical.
Citation ID 02001
Citaton Type Other
Standard Cited 19100132 D02
Issuance Date 2015-06-11
Abatement Due Date 2015-07-08
Current Penalty 400.0
Initial Penalty 400.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 25
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: (a) On or about 2/10/2015 at Diamond Furniture Services Inc., the employer did not assess the workplace's hazards and certify a written hazard assessment.
340345586 0215000 2015-02-10 544 PARK AVENUE, BROOKLYN, NY, 11205
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2015-02-10
Case Closed 2018-04-10

Related Activity

Type Complaint
Activity Nr 923815
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100037 A03
Issuance Date 2015-07-06
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. No materials or equipment may be placed, either permanently or temporarily. Site: 544 Park Avenue Brooklyn, NY On or about 2/10/15 a) The emergency exit in the Re-upholstery area was blocked by debris, garbage, bags and a desk.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2015-07-06
Abatement Due Date 2015-07-16
Current Penalty 4900.0
Initial Penalty 4900.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by in-going nip points, rotating parts, and/or flying chips and sparks. Site: 544 Park Avenue Brooklyn, NY On or about 2/10/15 a)The Dewalt Powermatic saw used by employees was not provided with a guard.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100303 G02 I
Issuance Date 2015-07-06
Abatement Due Date 2015-07-16
Current Penalty 2100.0
Initial Penalty 2100.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures. Site: 544 Park Avenue Brooklyn, NY On or about 2/10/15 a) Panelboard in the Finish and spray booth area was not provided with a cover. Employees exposed to arc while working/walking by enclosure.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100305 B02 I
Issuance Date 2015-07-06
Abatement Due Date 2015-07-16
Current Penalty 4200.0
Initial Penalty 4200.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose; and each outlet box in completed installations did not have a cover, face plate or fixture canopy. Site: 544 Park Avenue Brooklyn, NY On or about 2/10/15 a) Employee was exposed to electrical shock due to exposed live electricity. The light switch by the entrance of the spry booth was missing the face plate.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100305 G01 IV A
Issuance Date 2015-07-06
Abatement Due Date 2015-07-16
Current Penalty 2100.0
Initial Penalty 2100.0
Final Order 2015-08-03
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): 29 CFR 1910.305(g)(1)(iv)A: Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for permanent building wiring. Site: 544 Park Avenue Brooklyn, NY On or about 2/10/15 a) Extension Cords throughout the establishment were used in place of permanent wiring. Extension cords used to energize lights throughout facility.

Date of last update: 30 Mar 2025