Search icon

ZIO CONSTRUCTION INC.

Company Details

Name: ZIO CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 09 Jul 2001 (24 years ago)
Date of dissolution: 28 Jul 2010
Entity Number: 2658029
ZIP code: 10038
County: Queens
Place of Formation: New York
Address: 45 JOHN STREET, SUITE 711, NEW YORK, NY, United States, 10038

Shares Details

Shares issued 20000

Share Par Value 1

Type PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 45 JOHN STREET, SUITE 711, NEW YORK, NY, United States, 10038

Agent

Name Role Address
SPIEGEL & UTRERA, P.A., P.C. Agent 45 JOHN STREET, SUITE 711, NEW YORK, NY, 10038

Filings

Filing Number Date Filed Type Effective Date
DP-1880461 2010-07-28 DISSOLUTION BY PROCLAMATION 2010-07-28
010709000065 2001-07-09 CERTIFICATE OF INCORPORATION 2001-07-09

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339549230 0214700 2014-01-16 64 NORTH COUNTRY ROAD, SMITHTOWN, NY, 11787
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-01-16
Emphasis L: FALL, P: FALL
Case Closed 2015-02-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-02-18
Abatement Due Date 2014-02-24
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-03-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Worksite - An employee installing shingles with a pneumatic nail gun was not wearing eye protection; on or about 01/16/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-02-18
Abatement Due Date 2014-02-24
Current Penalty 600.0
Initial Penalty 1200.0
Final Order 2014-03-20
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) worksite - An employee working directly below ongoing roofwork was not wearing head protection; on or about 01/16/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B05 I
Issuance Date 2014-02-18
Abatement Due Date 2014-02-24
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-03-20
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: a) worksite - An employee was working on a scaffold platform that extended approximately 18 inches over its support; on or about 01/16/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2014-02-18
Abatement Due Date 2014-02-24
Current Penalty 1400.0
Initial Penalty 2800.0
Final Order 2014-03-20
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite - An employee installing shingles approximately 20 feet 6 inches above the ground from an elevated work platform was not protected from falling; on or about 01/16/2014. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-02-18
Abatement Due Date 2014-02-24
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-03-20
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) worksite - Employees were using an unsecured ladder to access the upper landing. The ladders side rails were approximately 2 inches above the upper landing; on or about 01/16/2014. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 30 Mar 2025

Sources: New York Secretary of State