Name: | ALEKSEY CONSTRUCTION CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 23 Jul 2001 (24 years ago) |
Date of dissolution: | 28 Jul 2010 |
Entity Number: | 2662885 |
ZIP code: | 11375 |
County: | Queens |
Place of Formation: | New York |
Address: | ALEKSEY SHIMONOV, 63-36 110TH ST. / 2ND FLOOR, FOREST HILLS, NY, United States, 11375 |
Contact Details
Phone +1 718-275-1729
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | ALEKSEY SHIMONOV, 63-36 110TH ST. / 2ND FLOOR, FOREST HILLS, NY, United States, 11375 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1328356-DCA | Inactive | Business | 2009-08-11 | 2011-06-30 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
DP-1881421 | 2010-07-28 | DISSOLUTION BY PROCLAMATION | 2010-07-28 |
010723000050 | 2001-07-23 | CERTIFICATE OF INCORPORATION | 2001-07-23 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
972008 | LICENSE | INVOICED | 2009-08-11 | 100 | Home Improvement Contractor License Fee |
972009 | TRUSTFUNDHIC | INVOICED | 2009-08-06 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339226078 | 0215600 | 2013-07-22 | 166-07 81 AVENUE, JAMAICA, NY, 11432 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 834509 |
Safety | Yes |
Type | Inspection |
Activity Nr | 922584 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260404 B01 |
Issuance Date | 2013-08-09 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1): The Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. Location: 166-07 81 Avenue Queens NY. On or About: 07/22/13 a) The Reciprocating Saw being used by the employees was not provided with a GFCI protection or an assured equipment grounding program. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260404 F06 |
Issuance Date | 2013-08-09 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2013-10-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. Location: 166-07 81 Avenue Queens NY. On or About: 07/22/13 a)The orange 25 feet extension cord use to energize the Reciprocating Saw was missing the ground pin. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B04 I |
Issuance Date | 2013-08-09 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-10-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Location: 166-07 81 Avenue Queens, NY. On or about: 07/22/13 a) Employees walked and worked near the a floor hole located at the stairway which was not guarded. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261052 C01 |
Issuance Date | 2013-08-09 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2013-10-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Location: 166-07 81 Avenue Queens, NY. On or about: 07/22/13 a) Employees used the stairways from the basement to the first floor which was not equppied with stairrails and handrails along each unprotected side or edge. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2011-10-21 |
Emphasis | L: FALL, S: RESIDENTIAL CONSTR, S: FALL FROM HEIGHT |
Case Closed | 2015-12-07 |
Related Activity
Type | Referral |
Activity Nr | 200837375 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260025 A |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 1800.0 |
Initial Penalty | 1800.0 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 01 |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260096 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 1800.0 |
Initial Penalty | 1800.0 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 01 |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 01 |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19260451 A01 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 3000.0 |
Initial Penalty | 3000.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 05 |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19260452 I07 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 05 |
Citation ID | 01003C |
Citaton Type | Serious |
Standard Cited | 19260452 I08 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 05 |
Citation ID | 01004A |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 4200.0 |
Initial Penalty | 4200.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
Citation ID | 01004B |
Citaton Type | Serious |
Standard Cited | 19260501 B02 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
Citation ID | 01004C |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 10 |
Citation ID | 01004D |
Citaton Type | Serious |
Standard Cited | 19260501 B14 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261052 C01 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 1800.0 |
Initial Penalty | 1800.0 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 01 |
Citation ID | 02001A |
Citaton Type | Repeat |
Standard Cited | 19260451 B01 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Current Penalty | 6000.0 |
Initial Penalty | 6000.0 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 03 |
Citation ID | 02001B |
Citaton Type | Repeat |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 03001 |
Citaton Type | Other |
Standard Cited | 19261053 B16 |
Issuance Date | 2011-12-15 |
Abatement Due Date | 2011-12-20 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 01 |
Inspection Type | FollowUp |
Scope | NoInspection |
Safety/Health | Safety |
Case Closed | 2010-03-03 |
Related Activity
Type | Inspection |
Activity Nr | 313425746 |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2009-11-03 |
Emphasis | S: FALL FROM HEIGHT, L: FALL |
Case Closed | 2015-12-08 |
Related Activity
Type | Referral |
Activity Nr | 200835692 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-31 |
Current Penalty | 450.0 |
Initial Penalty | 450.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 01 |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Current Penalty | 600.0 |
Initial Penalty | 600.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 02 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Current Penalty | 750.0 |
Initial Penalty | 750.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 01004A |
Citaton Type | Serious |
Standard Cited | 19260451 C02 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Current Penalty | 750.0 |
Initial Penalty | 750.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 01004B |
Citaton Type | Serious |
Standard Cited | 19260451 C02 II |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 01004C |
Citaton Type | Serious |
Standard Cited | 19260451 C03 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19260451 E01 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Current Penalty | 750.0 |
Initial Penalty | 750.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 03 |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 |
Issuance Date | 2009-12-22 |
Abatement Due Date | 2009-12-29 |
Current Penalty | 1500.0 |
Initial Penalty | 1500.0 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Referral |
Gravity | 10 |
Date of last update: 30 Mar 2025