Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2016-08-31
|
Emphasis |
L: FALL
|
Case Closed |
2017-03-09
|
Related Activity
Type |
Complaint |
Activity Nr |
1134867 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 B01 I |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2016-12-13 |
Current Penalty |
1203.0 |
Initial Penalty |
1604.0 |
Final Order |
2016-12-27 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, on the first floor, on or about 8/31/16: The employer provided an office style power strip for use at the jobsite that was not listed and labeled for construction use. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2016-12-13 |
Current Penalty |
2805.75 |
Initial Penalty |
3741.0 |
Final Order |
2016-12-27 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, on the first floor, on or about 8/31/16: The employer did not ensure that employees working near or transiting in close proximity to an open stairwell to the basement were protected from falling 7.5 feet to the lower level. b) At the jobsite, on the second floor, on or about 8/31/16: The employer did not ensure that employees working near or transiting in close proximity to an open stairwell to the lower floor were protected from falling 8 feet to the lower level. c) At the jobsite, on the second floor, on or about 8/31/16: The employer did not ensure that employees working near or transiting in close proximity to an open stairwell to the lower floor were protected from falling 8 feet to the lower level. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B14 |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2016-12-13 |
Current Penalty |
2805.75 |
Initial Penalty |
3741.0 |
Final Order |
2016-12-27 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. a) At the jobsite, on the street side of the building (West), on the South side of the building, and on the East side of the building, on or about 8/31/16: The employer did not ensure that floor to celling window openings on the second floor, 8 feet from grade and window openings with sill heights 12 inches from the deck and 8 feet from grade, were fitted with guardrail systems. a) At the jobsite, on the street side of the building (West), on the South side of the building, and on the East side of the building, on or about 8/31/16: The employer did not ensure that floor to celling window openings on the third floor, 16 feet from grade and window openings with sill heights 12 inches from the deck and 16 feet from grade, were fitted with guardrail systems. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 I04 |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2016-12-13 |
Current Penalty |
1603.5 |
Initial Penalty |
2138.0 |
Final Order |
2016-12-27 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a) At the jobsite, on the first floor and second floor, on or about 8/31/16: The employer directed that holes were covered and those covers were not marked with "hole" or "cover". |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2016-12-07 |
Abatement Due Date |
2016-12-13 |
Current Penalty |
1603.5 |
Initial Penalty |
2138.0 |
Final Order |
2016-12-27 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) At the jobsite, on the first floor, on or about 8/31/16: The employer did not ensure that employees using a stairwell from the first floor to the basement were provided at least one handrail. b) At the jobsite, on the second floor, on or about 8/31/16: The employer did not ensure that employees using a stairwell from the first floor to the second floor were provided at least one handrail. c) At the jobsite, on the second floor, on or about 8/31/16: The employer did not ensure that employees using a stairwell from the first floor to the second floor were provided at least one handrail. |
|
|