Name: | J. FRANK & ASSOCIATES LTD. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 14 Jan 2002 (23 years ago) |
Entity Number: | 2718589 |
ZIP code: | 10977 |
County: | Rockland |
Place of Formation: | New York |
Address: | 24A WASHINGTON AVE, SPRING VALLEY, NY, United States, 10977 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 24A WASHINGTON AVE, SPRING VALLEY, NY, United States, 10977 |
Name | Role | Address |
---|---|---|
JACOB FRANK | Chief Executive Officer | 24A WASHINGTON AVE, SPRING VALLEY, NY, United States, 10977 |
Start date | End date | Type | Value |
---|---|---|---|
2004-01-15 | 2014-03-05 | Address | 24A WASHINGTON AVE, SPRING VALLEY, NY, 10977, USA (Type of address: Principal Executive Office) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
140305002422 | 2014-03-05 | BIENNIAL STATEMENT | 2014-01-01 |
120210002007 | 2012-02-10 | BIENNIAL STATEMENT | 2012-01-01 |
100129002470 | 2010-01-29 | BIENNIAL STATEMENT | 2010-01-01 |
080107002403 | 2008-01-07 | BIENNIAL STATEMENT | 2008-01-01 |
060209003234 | 2006-02-09 | BIENNIAL STATEMENT | 2006-01-01 |
040115002273 | 2004-01-15 | BIENNIAL STATEMENT | 2004-01-01 |
020114000683 | 2002-01-14 | CERTIFICATE OF INCORPORATION | 2002-01-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
339635120 | 0216000 | 2014-03-13 | WEINER DR. & BUTTERMAN CT., MONSEY, NY, 10952 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Referral |
Activity Nr | 876503 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260404 B01 I |
Issuance Date | 2014-03-31 |
Current Penalty | 700.0 |
Initial Penalty | 2000.0 |
Contest Date | 2014-04-28 |
Final Order | 2014-08-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. location: interior of building, lot 21-22 on or about: 03/13/14 a) Employees were using equipment, including a Makita sander, that were plugged into extension cords. The employees were not provided with GFCI protection or an assured equipment grounding conductor program. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2014-03-31 |
Abatement Due Date | 2014-04-08 |
Current Penalty | 1000.0 |
Initial Penalty | 2800.0 |
Contest Date | 2014-04-28 |
Final Order | 2014-08-06 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems: location: 3rd floor, lot 21-22 a) Employees, installing the permanent stairrail and hallway banister, were not provided with any means of fall protection. The employees were exposed to a fall of 10 1/2 feet. |
Citation ID | 01003A |
Citaton Type | Serious |
Standard Cited | 19261052 C01 I |
Issuance Date | 2014-03-31 |
Abatement Due Date | 2014-04-08 |
Current Penalty | 1000.0 |
Initial Penalty | 2800.0 |
Contest Date | 2014-04-28 |
Final Order | 2014-08-06 |
Nr Instances | 2 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one hand rail: location: stairs between 1st and 3rd floors, lot 21-22 on or about: 3/13/14 a) Employees, installing the permanent stairrail, were not provided with a temporary hand rail. |
Citation ID | 01003B |
Citaton Type | Serious |
Standard Cited | 19261052 C01 II |
Issuance Date | 2014-03-31 |
Abatement Due Date | 2014-04-08 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2014-04-28 |
Final Order | 2014-08-06 |
Nr Instances | 4 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with one stairrail system along each unprotected side or edge: location: stairs between 1st and 3rd floors, lot 21-22 on or about: 3/13/14 a) Employeee were using the stairs to access the upper levels and were working from the stairs while installing the permanent stairrails. The open sided stairs were not provided with temporary stairrails. |
Citation ID | 02001 |
Citaton Type | Other |
Standard Cited | 19260404 F06 |
Issuance Date | 2014-03-31 |
Abatement Due Date | 2014-04-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2014-04-28 |
Final Order | 2014-08-06 |
Nr Instances | 2 |
Nr Exposed | 2 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent and continuous: location: interior of building, lot 21-22 on or about: 03/13/14 a) Employees were using a Makita sander. The sander was plugged into an extension cord that was missing the grounding pin. |
Date of last update: 30 Mar 2025