Search icon

ADVANCED SEAMLESS GUTTERS, INC.

Company Details

Name: ADVANCED SEAMLESS GUTTERS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 06 Feb 2002 (23 years ago)
Entity Number: 2728028
ZIP code: 11704
County: Suffolk
Place of Formation: New York
Address: 316 OLD FARMINGDALE ROAD, WEST BABYLON, NY, United States, 11704
Principal Address: 316 OLD FARMINGDALE RD, WEST BABYLON, NY, United States, 11704

Shares Details

Shares issued 20000

Share Par Value 1

Type PAR VALUE

Agent

Name Role Address
SPIEGEL & UTRERA, P.A.P.C. Agent 45 JOHN STREET, SUITE 711, NEW YORK, NY, 10038

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 316 OLD FARMINGDALE ROAD, WEST BABYLON, NY, United States, 11704

Chief Executive Officer

Name Role Address
ROSA MARIA SASSO Chief Executive Officer 316 OLD FARMINGDALE RD, WEST BABYLON, NY, United States, 11704

Filings

Filing Number Date Filed Type Effective Date
040130002211 2004-01-30 BIENNIAL STATEMENT 2004-02-01
020206000485 2002-02-06 CERTIFICATE OF INCORPORATION 2002-02-06

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339763872 0214700 2014-05-12 250 OLD FARMINGDALE ROAD, WEST BABYLON, NY, 11704
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-05-12
Emphasis L: FALL, L: SANDY, P: FALL
Case Closed 2014-11-12

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-05-23
Current Penalty 0.0
Initial Penalty 1200.0
Contest Date 2014-06-18
Final Order 2014-09-22
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) worksite - Employees were installing shingles with a pneumatic nail gun without using eye protection; on or about 05/12/2014 Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2014-05-23
Current Penalty 0.0
Initial Penalty 1200.0
Contest Date 2014-06-18
Final Order 2014-09-22
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) worksite - An employee bringing shingles to employees for installation directly under ongoing roof work was not using head protection; 05/12/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-05-23
Current Penalty 0.0
Initial Penalty 1600.0
Contest Date 2014-06-18
Final Order 2014-09-22
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) worksite - Employees installing shingles on an approximate 6-12 pitch roof, approximately 8 feet above the ground were not protected from falling; on or about 05/12/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-05-23
Current Penalty 0.0
Initial Penalty 1600.0
Contest Date 2014-06-18
Final Order 2014-09-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) worksite - Employees were using an unsecured ladder to access the roof. The ladders side rails were approximately 18 inches above the upper landing; on or about 05/12/2014. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
315996207 0214700 2011-12-13 15 DAMSON ST., GARDEN CITY, NY, 11530
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2011-12-13
Emphasis L: FALL
Case Closed 2012-12-11

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100023 C01
Issuance Date 2012-01-30
Abatement Due Date 2012-02-09
Current Penalty 1000.0
Initial Penalty 3000.0
Nr Instances 1
Nr Exposed 1
Gravity 05

Date of last update: 30 Mar 2025

Sources: New York Secretary of State