Search icon

BRICKHOUSE MASONRY, LLC

Company Details

Name: BRICKHOUSE MASONRY, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 07 Feb 2002 (23 years ago)
Entity Number: 2728381
ZIP code: 11738
County: Suffolk
Place of Formation: New York
Address: PO BOX 502, FARMINGVILLE, NY, United States, 11738

DOS Process Agent

Name Role Address
BRICKHOUSE MASONRY, LLC DOS Process Agent PO BOX 502, FARMINGVILLE, NY, United States, 11738

History

Start date End date Type Value
2008-02-12 2014-02-06 Address PO BOX 502 AVE, FARMINGVILLE, NY, 11738, USA (Type of address: Service of Process)
2002-02-07 2008-02-12 Address 77 OAKLAWN AVE, FARMINGVILLE, NY, 11738, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
140206006639 2014-02-06 BIENNIAL STATEMENT 2014-02-01
100305002906 2010-03-05 BIENNIAL STATEMENT 2010-02-01
080212002299 2008-02-12 BIENNIAL STATEMENT 2008-02-01
060301002109 2006-03-01 BIENNIAL STATEMENT 2006-02-01
040116002399 2004-01-16 BIENNIAL STATEMENT 2004-02-01
020702000715 2002-07-02 AFFIDAVIT OF PUBLICATION 2002-07-02
020702000709 2002-07-02 AFFIDAVIT OF PUBLICATION 2002-07-02
020207000178 2002-02-07 ARTICLES OF ORGANIZATION 2002-02-07

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
341965838 0214700 2016-11-18 9 RED CEDAR ROAD, SOUTHAMPTON, NY, 11968
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2016-11-18
Emphasis L: FALL
Case Closed 2017-04-27

Related Activity

Type Inspection
Activity Nr 1131942
Safety Yes
341319424 0214700 2016-03-11 9 RED CEDAR ROAD, SOUTHAMPTON, NY, 11968
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2016-03-11
Emphasis L: FALL
Case Closed 2017-01-03

Related Activity

Type Referral
Activity Nr 1071392
Safety Yes
Type Inspection
Activity Nr 1131941
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C01 I
Issuance Date 2016-08-18
Abatement Due Date 2016-08-24
Current Penalty 1604.0
Initial Penalty 1604.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1)(i): Guys, ties, and braces were not installed at locations where horixontal members support both inner and outer legs: a) Worksite, northwest corner of house: Employees were doing bricklaying work from a scaffold that was not provided with cross bracing on the inside (side closer to building) to provide support to the inner legs; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2016-08-18
Abatement Due Date 2016-08-25
Current Penalty 1604.0
Initial Penalty 1604.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a) Worksite, northwest side of house: Employees were doing bricklaying work from a scaffold that stood on the ground without a base plate or other adequate firm foundation on the north inner leg; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2016-08-18
Abatement Due Date 2016-08-26
Current Penalty 1604.0
Initial Penalty 1604.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a) Worksite, rear of house: Employees were accessing the interior of the new residential construction to do work and transport materials. The employees used a bucket to access the landing approximately 32 in. above the ground and were not provided with a stairway or its equivalent; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2016-08-18
Abatement Due Date 2016-09-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met (Construction Reference: 1926.59): a) Worksite, northwest side of house: Employees were doing bricklaying work using chemicals such as, but not limited to, Portland cement. A written hazard communication program was not in place; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. ABATEMENT NOTE: The written Hazard Communication Program must include descriptions of how the following program elements, required by this regulation, will be developed, implemented, and conveyed to the employer's employee(s) who are exposed to hazardous materials: a. Labeling and other forms or warning: Labels shall include at least the identity of the hazardous chemical(s), the appropriate hazard warnings, the target organs, and the name and address of the chemical manufacturer, importer or other responsible party; b. A list or inventory of all hazardous materials known to be present in the workplace must be compiled and be maintained as part of the employer's written Hazard Communication Program; c. Material Safety Data Sheets (MSDSs) for all materials used by employee(s) in the workplace must be maintained and readily available all employee(s) on all shifts. d. The employer's Hazardous Materials Information and Training Program must be based upon the employer's written Hazard Communication Program. The training for employee(s) must include at least: Methods and observation that may be used to detect the presence or release of hazardous chemicals in the work area. The physical and health hazards of the chemicals in the work area. The measures employee(s) can take to protect themselves, such as, specific procedures, appropriate work practices, emergency procedures, and personal protective equipment to be used. The details of the employer's Hazard Communication Program including an explanation of the labeling systems used, Material Safety Data Sheets and how employees can obtain and use the appropriate hazard information; e. Methods used to inform employees of the hazards associated with non routine tasks must also be addressed in the employer's written program; and f. The employer's written Hazard Communication Program must be made available upon request. For Multi Employer Work places, the employer's Written Hazard Communication Program must also specifically address how: a. Material Safety Data Sheets for each hazardous material on the job site will be provided to other employers in the event the other employer's employee(s) may be exposed to these materials. b. The methods the employer will use to inform other employer(s) of any precautionary measures that need to be taken to protect employee(s) during normal operating conditions and in foreseeable emergencies. c. The methods the employer will use to inform the other employer(s) of the labeling system used in the workplace.
Citation ID 02001B
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2016-08-18
Abatement Due Date 2016-08-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: a) Worksite, northwest side of house: Employees were doing bricklaying work using chemicals such as, but not limited to, Portland cement. Safety data sheets were not made available; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2016-08-18
Abatement Due Date 2016-09-01
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2016-09-20
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Worksite, northwest side of house: Employees were doing bricklaying work using chemicals such as, but not limited to, Portland cement. A training program for hazard communication was not in place; on or about 3/11/16. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1655579 Intrastate Non-Hazmat 2007-06-13 - - 9 8 Private(Property)
Legal Name BRICKHOUSE MASONRY LLC
DBA Name -
Physical Address 77 OAKLAWN AVENUE, FARMINGVILLE, NY, 11738, US
Mailing Address 77 OAKLAWN AVENUE, FARMINGVILLE, NY, 11738, US
Phone (631) 736-1790
Fax -
E-mail -

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 30 Mar 2025

Sources: New York Secretary of State