OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343012019 0215800 2018-02-26 IRISH CULTURAL CENTER, 623 COLUMBIA STREET, UTICA, NY, 13502
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-02-26
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2022-11-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260153 O
Issuance Date 2018-03-26
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-04-19
Nr Instances 5
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: a) South side of building, on or about 2-26-18: Motor vehicles were being operated immediately adjacent to two tandemly connected 1,000 gallon Liquefied Petroleum Gas (LPG) tanks that had no protection against accidental contact. b) Southwest corner of building, on or about 2-26-18: Motor vehicles were being operated immediately adjacent to a 250 gallon Liquefied Petroleum Gas (LPG) tank that had no protection against accidental contact. c) West side of building, on or about 2-26-18: Motor vehicles were being operated immediately adjacent to a 250 gallon Liquefied Petroleum Gas (LPG) tank that had no protection against accidental contact. d) Southwest corner of building, on or about 2-26-18: Motor vehicles were being operated immediately adjacent to a 100 gallon Liquefied Petroleum Gas (LPG) tank that had no protection against accidental contact.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-03-26
Current Penalty 2772.0
Initial Penalty 2772.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is not greater than 1 inch (2.5 cm) wide: a) West side of building, south west corner, on or about 2-26-18: One employee was working on a scaffold platform that was not fully planked, exposing the employee to a fall hazard of 11 feet 8 inches.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2018-03-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a) West side of building, south west corner, on or about 2-26-18: One employee was working on a scaffold platform that was 9-1/ inches wide, less than the required minimum width of 18 inches, exposing the employee to a fall hazard of 11 feet 8 inches.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-03-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 1
Nr Exposed 1
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a) West side of building, south west corner, on or about 2-26-18: One employee was using cross braces and scaffold frames for scaffold access, exposing the employee to a fall hazard of up to 17 feet 4 inches.
Citation ID 01002D
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2018-03-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-04-19
Nr Instances 3
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) West side of building, south west corner, on or about 2-26-18: One employee was working on two outrigger bracket scaffold platforms without the use of fall protection, exposing the employee to a fall hazard of 18 feet 2 inches and 11 feet 8 inches respectively. b) West side of building, south west corner, on or about 2-26-18: One employee was working on an unprotected open sided scaffold platform without the use of fall protection, exposing the employee to a fall hazard of 13 feet 5 inches. c) West side of building, south west corner, on or about 2-26-18: One employee was working on a scaffold platform with an unprotected open end of the walk through frame, exposing the employee to a fall hazard of 13 feet 5 inches.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
6823177400 2020-05-15 0248 PPP 1465 SOUTH PARK DRIVE, UTICA, NY, 13501
Loan Status Date 2021-04-06
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 31112.5
Loan Approval Amount (current) 31112.5
Undisbursed Amount 0
Franchise Name -
Lender Location ID 50298
Servicing Lender Name Bank of Utica
Servicing Lender Address 222 Genesee St, UTICA, NY, 13502-4320
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description Existing or more than 2 years old
Project Address UTICA, ONEIDA, NY, 13501-1000
Project Congressional District NY-22
Number of Employees 5
NAICS code 238140
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 50298
Originating Lender Name Bank of Utica
Originating Lender Address UTICA, NY
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 31381.01
Forgiveness Paid Date 2021-03-30

Date of last update: 30 Mar 2025

Sources: New York Secretary of State