Search icon

KINGSTONE MASONRY & BRICK WORK, INC.

Company Details

Name: KINGSTONE MASONRY & BRICK WORK, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 May 2002 (23 years ago)
Entity Number: 2762027
ZIP code: 10550
County: Westchester
Place of Formation: New York
Address: NINE ROCHELLE TERRACE, MOUNT VERNON, NY, United States, 10550

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent NINE ROCHELLE TERRACE, MOUNT VERNON, NY, United States, 10550

Filings

Filing Number Date Filed Type Effective Date
020502000357 2002-05-02 CERTIFICATE OF INCORPORATION 2002-05-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339011728 0216000 2013-04-16 122-134 MAMARONECK AVENUE, MAMARONECK, NY, 10543
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2013-04-16
Case Closed 2014-03-21

Related Activity

Type Referral
Activity Nr 814107
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2013-09-30
Current Penalty 720.0
Initial Penalty 1200.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about 4/16/13 Location: 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) A metal quad outlet "J" box was used as a distribution point on the end of an orange extemsion cord.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2013-09-30
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about 4/16/13 Location: 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) The orange extension cord used to feed the metal "J" box was not protected by strain relief where it entered the box.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260850 A
Issuance Date 2013-09-30
Current Penalty 1680.0
Initial Penalty 2800.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations: On or about 4/16/13 Location: 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) The employer did not have a written engineering survey and demolition plan available on site.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2013-09-30
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about 4/16/13 Location 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) A six foot "A" frame ladder was used in the closed position to access a flat roof at a height of nine feet. The side rails did not extend three feet above the landing.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2013-09-30
Current Penalty 960.0
Initial Penalty 1600.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: On or about 4/16/13 Location: 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) An "A" frame six foot step ladder was used in the closed position like a straight ladder.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2013-09-30
Abatement Due Date 2013-10-25
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2013-11-29
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: On or about 4/16/13 Location: 122-134 Mamaroneck Avenue, Mamaroneck, NY 10543 a) Employees using ladders improperly were not trained in recognizing the hazards associated with ladder use and the proceedures to be followed to minimize such hazards.

Date of last update: 30 Mar 2025