Search icon

THURSDAY'S EATERY, INC.

Headquarter

Company Details

Name: THURSDAY'S EATERY, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Jun 2002 (23 years ago)
Entity Number: 2784405
ZIP code: 11040
County: New York
Place of Formation: New York
Address: 1414 HILLSIDE AVENUE, NEW HYDE PARK, NY, United States, 11040
Principal Address: 1414 HILLSIDE AVE, NEW HYDE PARK, NY, United States, 11040

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Links between entities

Type Company Name Company Number State
Headquarter of THURSDAY'S EATERY, INC., CONNECTICUT 1169473 CONNECTICUT

Chief Executive Officer

Name Role Address
SANJIV CHAND Chief Executive Officer 1414 HILLSIDE AVE, NEW HYDE PARK, NY, United States, 11040

DOS Process Agent

Name Role Address
SANJIV CHAND DOS Process Agent 1414 HILLSIDE AVENUE, NEW HYDE PARK, NY, United States, 11040

History

Start date End date Type Value
2020-02-04 2023-02-24 Address 1414 HILLSIDE AVENUE, NEW HYDE PARK, NY, 11040, USA (Type of address: Service of Process)
2016-06-13 2020-02-04 Address 65 HAMILTON DRIVE, ROSLYN, NY, 11576, USA (Type of address: Service of Process)
2014-11-18 2023-02-24 Address 1414 HILLSIDE AVE, NEW HYDE PARK, NY, 11040, USA (Type of address: Chief Executive Officer)
2014-03-11 2016-06-13 Address 1414 HILLSIDE AVE, NEW HYDE PARK, NY, 11040, USA (Type of address: Service of Process)
2014-03-11 2014-11-18 Address 1414 HILLSIDE AVE, NEW HYDE PARK, NY, 11040, USA (Type of address: Chief Executive Officer)
2009-08-10 2014-03-11 Address 65 HAMILTON AVENUE, ROSLYN, NY, 11576, USA (Type of address: Service of Process)
2002-06-28 2023-02-24 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2002-06-28 2009-08-10 Address 1211 AVENUE OF THE AMERICAS, SUITE 1502, NEW YORK, NY, 10036, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230224001549 2023-02-24 CERTIFICATE OF AMENDMENT 2023-02-24
200602060316 2020-06-02 BIENNIAL STATEMENT 2020-06-01
200204061874 2020-02-04 BIENNIAL STATEMENT 2018-06-01
160613006220 2016-06-13 BIENNIAL STATEMENT 2016-06-01
141118006095 2014-11-18 BIENNIAL STATEMENT 2014-06-01
140311002525 2014-03-11 BIENNIAL STATEMENT 2012-06-01
110509000135 2011-05-09 CERTIFICATE OF AMENDMENT 2011-05-09
090810000045 2009-08-10 CERTIFICATE OF AMENDMENT 2009-08-10
020628000651 2002-06-28 CERTIFICATE OF INCORPORATION 2002-06-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
337029797 0213100 2012-10-23 490 ROUTE 211, MIDDLETOWN, NY, 10940
Inspection Type Other-L
Scope Partial
Safety/Health Safety
Close Conference 2012-10-23
Case Closed 2013-09-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100005 A
Issuance Date 2013-03-27
Abatement Due Date 2013-04-08
Current Penalty 1000.0
Initial Penalty 4900.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.5(a): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to burn hazards: a) Kitchen area, on or prior to 10/23/2012: The employer did not ensure the Henny Penny 8-head pressure fryer(s) were maintained in safe operating condition, exposing employees to contact with hot oil during operation.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100022 A02
Issuance Date 2013-03-27
Abatement Due Date 2013-04-04
Current Penalty 1000.0
Initial Penalty 3500.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: a) Kitchen area, on or prior to 10/23/2012: -The floor was not kept in a dry condition in that the sink was leaking at the bottom drain, creating a slipping hazard for kitchen employees.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100132 D01 I
Issuance Date 2013-03-27
Abatement Due Date 2013-04-08
Current Penalty 800.0
Initial Penalty 4900.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(d)(1)(i): The employer did not select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment; a) Kitchen area, on or about 10/23/2012: Employees did not use personal protective equipment, including but not limited to insulated gloves, heavy-duty apron, and goggles (or face shield) during operation of Henny Penny 8-head pressure fryers, resulting in exposure to burn hazards.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100133 A01
Issuance Date 2013-03-27
Abatement Due Date 2013-04-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: a) Kitchen area, on or about 10/23/2012: Employees were not required to use goggles and/or a faceshield for protection from hot oil splash hazards during operation of Henny Penny 8-head pressure fryers, including but not limited to operations such as: morning start up and cleaning.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100138 A
Issuance Date 2013-03-27
Abatement Due Date 2013-04-08
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. a) Kitchen area, on or about 10/23/2012: Employees were not required to use protective gloves for protection from burn hazards during operation of Henny Penny 8-head pressure fryers.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100132 F01
Issuance Date 2013-03-27
Abatement Due Date 2013-04-08
Current Penalty 800.0
Initial Penalty 3500.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: a) Kitchen area, on or prior to 10/23/2012: The employer did not ensure employees were trained in the use of PPE, including but not limited to insulated gloves, heavy-duty apron, and goggles (or face shield), for protection from burn hazards during operation of Henny Penny 8 head pressure fryers.
Citation ID 01005
Citaton Type Serious
Standard Cited 19100151 B
Issuance Date 2013-03-27
Abatement Due Date 2013-04-15
Current Penalty 800.0
Initial Penalty 3500.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 24
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(b): There was neither an infirmary, clinic, or hospital used for the treatment of all injured employees in near proximity to the workplace nor a person or persons adequately trained to render first aid: a) KFC Store #211, 490 Route 211 East, Middletown, NY, on or prior to 10/23/2012: Employees were not adequately trained to provide appropriate first aid response for severe burn injuries.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19100305 G01 IV B
Issuance Date 2013-03-27
Abatement Due Date 2013-04-04
Current Penalty 500.0
Initial Penalty 2800.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 4
Nr Exposed 14
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) Kitchen area, behind KFC display, on or about 10/23/2012; Four flexible cords were run above the ceiling, concealing possible defects and exposing employees to fire hazards.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2013-03-27
Abatement Due Date 2013-04-02
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 2
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) Kitchen area, near Henny Penny Fryer(s), on or about 10/23/2012: The flexible cord on the filter drain pump was visibly damaged and pulled from its strain relief. b) Kitchen area, behind KFC display, on or about 10/23/2012: Flexible cord (yellow) plugged into the outlet behind the display was pulled from its strain relief.
Citation ID 02001
Citaton Type Other
Standard Cited 19040004 A
Issuance Date 2013-03-27
Abatement Due Date 2013-04-04
Current Penalty 100.0
Initial Penalty 700.0
Contest Date 2013-04-22
Final Order 2013-08-23
Nr Instances 1
Nr Exposed 25
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a) KFC Store #211, 490 Route 211 East, Middletown, NY, on or about 10/23/2012; the employer did not record workplace injuries or illnesses on the OSHA Form 300 or equivalent for the calendar year 2012.

Date of last update: 30 Mar 2025