Search icon

INTERNATIONAL ORDNANCE TECHNOLOGIES, INC.

Company Details

Name: INTERNATIONAL ORDNANCE TECHNOLOGIES, INC.
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Active
Date of registration: 27 Aug 2002 (23 years ago)
Entity Number: 2805406
ZIP code: 14701
County: Chautauqua
Place of Formation: Delaware
Principal Address: TAMMY H. SNYDER, PRESIDENT, 101 HARRISON STREET, JAMESTOWN, NY, United States, 14701
Address: 101 HARRISON STREET, JAMESTOWN, NY, United States, 14701

Commercial and government entity program

CAGE number Status Type Established CAGE Update Date CAGE Expiration SAM Expiration
3KBG3 Active U.S./Canada Manufacturer 2003-10-06 2024-10-08 2029-10-08 2025-10-02

Contact Information

POC TAMMY H.. SNYDER
Phone +1 716-664-1100
Fax +1 716-664-1115
Address 101 HARRISON ST, JAMESTOWN, NY, 14701 6614, UNITED STATES

Ownership of Offeror Information

Highest Level Owner Information not Available
Immediate Level Owner Information not Available
List of Offerors (0) Information not Available

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 28 LIBERTY ST., NEW YORK, NY, 10005

DOS Process Agent

Name Role Address
INTERNATIONAL ORDNANCE TECHNOLOGIES, INC. DOS Process Agent 101 HARRISON STREET, JAMESTOWN, NY, United States, 14701

Chief Executive Officer

Name Role Address
TAMMY H. SNYDER Chief Executive Officer 2 CRAWFORD LANE, LAKEWOOD, NY, United States, 14750

History

Start date End date Type Value
2019-01-28 2020-12-23 Address 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Service of Process)
2002-08-27 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Registered Agent)
2002-08-27 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
201223060156 2020-12-23 BIENNIAL STATEMENT 2020-08-01
SR-35779 2019-01-28 CERTIFICATE OF CHANGE (BY AGENT) 2019-01-28
SR-35780 2019-01-28 CERTIFICATE OF CHANGE (BY AGENT) 2019-01-28
020827000384 2002-08-27 APPLICATION OF AUTHORITY 2002-08-27

USAspending Awards. Contracts

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
DO AWARD 0001 2008-03-28 2008-02-12 2008-02-12
Unique Award Key CONT_AWD_0001_9700_N0016407D4261_9700
Awarding Agency Department of Defense
Link View Page

Description

Title 20 MM CARTRIDGE LINK, MK 7 MOD 1
NAICS Code 332995: OTHER ORDNANCE AND ACCESSORIES MANUFACTURING
Product and Service Codes 1305: AMMUNITION, THROUGH 30 MM

Recipient Details

Recipient INTERNATIONAL ORDNANCE TECHNOLOGIES, INC.
UEI H5B3JFZ6V251
Legacy DUNS 137673237
Recipient Address UNITED STATES, 101 HARRISON STREET, JAMESTOWN, 147016614
DELIVERY ORDER AWARD 0002 2008-03-28 2008-05-08 2008-05-08
Unique Award Key CONT_AWD_0002_9700_N0016407D4261_9700
Awarding Agency Department of Defense
Link View Page

Award Amounts

Obligated Amount 216786.09
Current Award Amount 216786.09
Potential Award Amount 216786.09

Description

Title 20 MM CARTRIDGE LINK, MK 7 MOD 1
NAICS Code 332995: OTHER ORDNANCE AND ACCESSORIES MANUFACTURING
Product and Service Codes 1305: AMMUNITION, THROUGH 30 MM

Recipient Details

Recipient INTERNATIONAL ORDNANCE TECHNOLOGIES, INC.
UEI H5B3JFZ6V251
Legacy DUNS 137673237
Recipient Address UNITED STATES, 101 HARRISON STREET, JAMESTOWN, CHAUTAUQUA, NEW YORK, 147016614
No data IDV N0016407D4261 2008-10-24 No data No data
Unique Award Key CONT_IDV_N0016407D4261_9700
Awarding Agency Department of Defense
Link View Page

Description

Title 20 MM CARTRIDGE LINK, MK 7 MOD 1
NAICS Code 332995: OTHER ORDNANCE AND ACCESSORIES MANUFACTURING
Product and Service Codes 1305: AMMUNITION, THROUGH 30 MM

Recipient Details

Recipient INTERNATIONAL ORDNANCE TECHNOLOGIES, INC.
UEI H5B3JFZ6V251
Legacy DUNS 137673237
Recipient Address UNITED STATES, 101 HARRISON STREET, JAMESTOWN, 147016614

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346973506 0213600 2023-09-13 101 HARRISON STREET, JAMESTOWN, NY, 14701
Inspection Type FollowUp
Scope Partial
Safety/Health Health
Close Conference 2023-09-13
Case Closed 2023-09-28

Related Activity

Type Inspection
Activity Nr 1615427
Health Yes
346153000 0213600 2022-08-17 101 WEST HARRISON STREET, JAMESTOWN, NY, 14701
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2022-08-30
Emphasis N: AMPUTATE
Case Closed 2023-12-19

Related Activity

Type Complaint
Activity Nr 1929908
Safety Yes
Health Yes
Type Inspection
Activity Nr 1615427
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2022-09-23
Abatement Due Date 2022-11-10
Current Penalty 1600.0
Initial Penalty 3315.0
Contest Date 2022-10-19
Final Order 2023-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 07/24/2019, in the Press Room, employer did not conduct periodic inspections of the Lockout/Tagout procedures for machines such as, but not limited to: 60 Ton Federal Press, Pivot Press and 100 Ton Bliss Press. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2022-09-23
Abatement Due Date 2022-11-10
Current Penalty 2100.0
Initial Penalty 4144.0
Contest Date 2022-10-19
Final Order 2023-03-13
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a) On or about 08/17/2022, throughout the facility, employees, who are required to Lockout machines such as, but not limited to, mechanical power press: 60 Ton Precision Press, 60 Ton Minster Press, & 100 Ton Bliss Press, when performing maintenance or servicing activities such as changing/setting up/adjusting dies or unjamming/adjusting material on ram, were not trained as authorized employees. ABATEMENT DOCUMENTATION REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100217 C02 I A
Issuance Date 2022-09-23
Abatement Due Date 2022-11-10
Current Penalty 2100.0
Initial Penalty 4144.0
Contest Date 2022-10-19
Final Order 2023-03-13
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s) a) On or about 08/17/2022 in the press department; there was no point of operation guard on the Pivot Press while running in continuous mode exposing employees to amputation hazards. b) On or about 08/30/2022 in the press department; where the point of operation guard on the 100 Ton Minster press had an opening of 2.25 inches wide between the guard and the frame of press and approximately 12 inches from the point of operation. This 2.25 inch X 12 inch gap on the left side of the press allowed access to the point of operation over, under and around the guard exposing employees to amputation hazards. ABATEMENT DOCUMENTATION REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100217 C03 I C
Issuance Date 2022-09-23
Abatement Due Date 2022-11-10
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-10-19
Final Order 2023-03-13
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(c)(3)(i)(c):The employer did not provide and ensure the point of operation device prevented the operator from inadvertently reaching into the point of operation at all times: a) On or about 08/12/2022 in the press department; the point of operation device used for guarding (light curtain) the 100 Ton Bliss Press/Link Press was not adjusted to comply with Table O-10; a gap of 9 inches between the bottom of the light curtain and the bolster plate created exposure to the point of operation by reaching under the guard, exposing employees to amputation hazards. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01004
Citaton Type Serious
Standard Cited 19100217 E01 I A
Issuance Date 2022-09-23
Abatement Due Date 2022-11-10
Current Penalty 2100.0
Initial Penalty 4144.0
Contest Date 2022-10-19
Final Order 2023-03-13
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.217(e)(1)(i)(A): Under the general component of the inspection program, periodic and regular inspections were not conducted of each power press to ensure that all of its parts, auxiliary equipment, and safeguards, including the clutch/brake mechanism, antirepeat feature, and single-stroke mechanism, are in a safe operating condition and adjustment; a) On or about 08/30/2022, in the establishment, Employer did not perform inspections under the general component of the inspection program on part and full revolution mechanical power presses such as, but not limited to: 60 Ton Precision Press, 35 Ton Precision Press, 100 Ton Minster Press, 60 Ton Minster Press, 2 1/2 Ton Niagara Press, 100 Ton Bliss Press ABATEMENT DOCUMENTATION REQUIRED
346154271 0213600 2022-08-17 101 HARRISON STREET, JAMESTOWN, NY, 14701
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2022-08-17
Case Closed 2023-12-19

Related Activity

Type Complaint
Activity Nr 1929908
Safety Yes
Health Yes
Type Inspection
Activity Nr 1615300
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C
Issuance Date 2022-09-23
Abatement Due Date 2022-10-26
Current Penalty 1650.0
Initial Penalty 3315.0
Contest Date 2022-10-19
Final Order 2023-01-31
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c): The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use: a) Heat Treat Area - On or about 8/17/2022, employees were required by the employer to wear Northern Safety 9200 N95 filtering face-piece respirators while working at the Heat Treat Furnance to protect them from soot particulate. The employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use including selection, medical evaluation, fit-testing, training, and inspection. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2022-09-23
Abatement Due Date 2022-10-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-10-19
Final Order 2023-01-31
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Heat Treat Area - On or about 8/17/2022, employees were required by the employer to wear Northern Safety 9200 N95 filtering face-piece respirators while operating the Heat Treat furnace. The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 F02
Issuance Date 2022-09-23
Abatement Due Date 2022-10-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-10-19
Final Order 2023-01-31
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a) Heat Treat Area - On or about 8/17/2022, employees were required by the employer to wear Northern Safety 9200 N95 filtering face-piece respirators while operating the Heat Treat furnace. Employee(s) were not fit tested prior to initial use of the respirator. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001D
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2022-09-23
Abatement Due Date 2022-10-26
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2022-10-19
Final Order 2023-01-31
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) Heat Treat Area - On or about 8/17/2022, employees were required by the employer to Northern Safety 9200 N95 respirators while operating the Heat Treat furnace. Training was not provided prior to requiring employees to use a respirator in the workplace. Employer shall ensure each employee can demonstrate knowledge of at least the following: Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; What the limitations and capabilities of the respirator are; How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions; How to inspect, put on and remove, use, and check the seals of the respirator; What the procedures are for maintenance and storage of the respirator; How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators; and the general requirements of this section. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2022-09-23
Abatement Due Date 2022-10-11
Current Penalty 2450.0
Initial Penalty 4972.0
Contest Date 2022-10-19
Final Order 2023-01-31
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b):Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Link Press - On or about 8/17/22, compressed air used to blow out metal shavings from the press had a dead end pressure of > 80 psi. ABATEMENT CERTIFICATION REQUIRED

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P0829450 INTERNATIONAL ORDNANCE TECHNOLOGIES, INC. - H5B3JFZ6V251 101 HARRISON ST, JAMESTOWN, NY, 14701-6614
Capabilities Statement Link -
Phone Number 716-664-1100
Fax Number 716-664-1115
E-mail Address tsnyder@iotusa.net
WWW Page www.iotusa.net
E-Commerce Website http://www.iotusa.net
Contact Person TAMMY SNYDER
County Code (3 digit) 013
Congressional District 23
Metropolitan Statistical Area 3610
CAGE Code 3KBG3
Year Established 2002
Accepts Government Credit Card No
Legal Structure Subchapter S Corporation
Ownership and Self-Certifications Self-Certified Small Disadvantaged Business, Women-Owned Small Business, Woman Owned
Business Development Servicing Office BUFFALO DISTRICT OFFICE (SBA office code 0296)
Capabilities Narrative Metal Stamping, Wire Forming, Metal Finishing, Austemper Heat Treating, Assembly, Tool-room, Products Lines: Machine Gun Links, Stripper Clips, Fillers,Load Binders, Custom Wire Products, Custom Metal Stamped Products
Special Equipment/Materials Punch Presses, Stamping Presses, Austemper Furnace, Phosphate Line, Four-slides, Custom Wire Forming Equipment, Custom Assembly Equipment, Wire EDM and Fully Equipped Tool-room
Business Type Percentages Manufacturing (100 %)
Keywords machine gun links, ammunition links, metallic link, small caliber links, medium caliber links, 5.56MM M27 links, 7.62MM M13 links, 50 cal M9 links, 50 cal M15A2 links, 25MM M28 links, stripper clips, fillers, 20MM M14A2 links, 20MM MK7 links, 20MM M14A2N links, 20MM M12 link, metal stamping, wire forming, austemper heat treat, phosphate, metal finishing, linked ammunition, clipped ammunition, broom brush and mop, squeegees
Quality Assurance Standards ISO-9000 SeriesANSI/ASQC Z1.4MIL-STD-45662AMIL-Q-9858
Electronic Data Interchange capable -

Current Principals

Name Tammy Snyder
Role President
Name Lucienne G. Hedman
Role Treasurer

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level $0
Description Construction Bonding Level (aggregate)
Level $0
Description Service Bonding Level (per contract)
Level $0
Description Service Bonding Level (aggregate)
Level $0

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 332994
NAICS Code's Description Small Arms, Ordnance, and Ordnance Accessories Manufacturing
Buy Green Yes
Code 332510
NAICS Code's Description Hardware Manufacturing
Buy Green Yes
Code 332618
NAICS Code's Description Other Fabricated Wire Product Manufacturing
Buy Green Yes
Code 332811
NAICS Code's Description Metal Heat Treating
Buy Green Yes
Code 332813
NAICS Code's Description Electroplating, Plating, Polishing, Anodizing and Coloring
Buy Green Yes
Code 332992
NAICS Code's Description Small Arms Ammunition Manufacturing
Buy Green Yes
Code 332993
NAICS Code's Description Ammunition (except Small Arms) Manufacturing
Buy Green Yes
Code 332999
NAICS Code's Description All Other Miscellaneous Fabricated Metal Product Manufacturing
Buy Green Yes
Code 336415
NAICS Code's Description Guided Missile and Space Vehicle Propulsion Unit and Propulsion Unit Parts Manufacturing
Buy Green Yes
Code 339994
NAICS Code's Description Broom, Brush and Mop Manufacturing
Buy Green Yes
Code 339999
NAICS Code's Description All Other Miscellaneous Manufacturing
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Yes
Export Business Activities Manufacturer
Exporting to Australia; Brazil; Canada; Denmark; Israel; Mexico; Norway; Spain; Sweden; United Arab Emirates
Desired Export Business Relationships Contract manufacturing
Description of Export Objective(s) to Diversify Our Customer Base and Provide Products Worldwide

Date of last update: 30 Mar 2025

Sources: New York Secretary of State