Name: | MAKAN LAND DEVELOPMENT-TWO, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 17 Dec 2002 (22 years ago) |
Entity Number: | 2846202 |
ZIP code: | 10926 |
County: | Orange |
Place of Formation: | New York |
Address: | 35 BALMORAL COURT, HARRIMAN, NY, United States, 10926 |
Name | Role | Address |
---|---|---|
THE LLC | DOS Process Agent | 35 BALMORAL COURT, HARRIMAN, NY, United States, 10926 |
Start date | End date | Type | Value |
---|---|---|---|
2002-12-17 | 2015-06-18 | Address | 335 LAROE ROAD, CHESTER, NY, 10918, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
150618000436 | 2015-06-18 | CERTIFICATE OF CHANGE | 2015-06-18 |
071012000593 | 2007-10-12 | CERTIFICATE OF PUBLICATION | 2007-10-12 |
041227002581 | 2004-12-27 | BIENNIAL STATEMENT | 2004-12-01 |
021217000280 | 2002-12-17 | ARTICLES OF ORGANIZATION | 2002-12-17 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340994482 | 0216000 | 2015-10-15 | 190 SHELDON AVE., TARRYTOWN, NY, 10591 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 1030315 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2016-03-29 |
Current Penalty | 125.0 |
Initial Penalty | 1320.0 |
Contest Date | 2016-04-21 |
Final Order | 2016-11-10 |
Nr Instances | 3 |
Nr Exposed | 3 |
Related Event Code (REC) | Complaint |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: Location: Intersection of Sheldon Ave. and Browning Lane On or about: 10/15/15 a) Employees working beside a Komatsu PC170LC excavator were not wearing hard hats. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260200 G02 |
Issuance Date | 2016-03-29 |
Abatement Due Date | 2016-12-12 |
Current Penalty | 125.0 |
Initial Penalty | 2200.0 |
Contest Date | 2016-04-21 |
Final Order | 2016-11-10 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.200(g)(2): All traffic control signs or devices used for protection of construction workers did not conform to Part VI of the Manual of Uniform Traffic Control Devices (AMUTCD"), 1988 Edition, Revision 3, September 3, 1993, FHWA-SA-94-027 or Part VI of the Manual on Uniform Traffic Control Devices, Millennium Edition, December 2000, FHWA, which are incorporated by reference: Location: Intersection of Sheldon Ave. and Browning Lane On or about: 10/15/15 a) Employees were in the road while resetting a catch basin. There were no traffic control signs or devices used to protect the employees from vehicular traffic. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2015-08-21 |
Emphasis | N: TRENCH |
Case Closed | 2016-09-19 |
Related Activity
Type | Referral |
Activity Nr | 1013936 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1087763 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 K02 |
Issuance Date | 2015-12-01 |
Current Penalty | 700.0 |
Initial Penalty | 2800.0 |
Contest Date | 2015-12-28 |
Final Order | 2016-04-11 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employee(s)were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: On or about: 08/18/15 Location: Eton Place, Eastchester, NY a) The competent person on site failed to remove the employees from an 11. 5-foot deep excavation that was neither shored nor sloped; on or about 8/18/15. b) The competent person on site failed to remove the employees from an 5.6 -foot deep excavation that was neither shored nor slope; on or about 10/21/15. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260651 J02 |
Issuance Date | 2015-12-01 |
Current Penalty | 700.0 |
Initial Penalty | 2800.0 |
Contest Date | 2015-12-28 |
Final Order | 2016-04-11 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: Location: Eton Place, Eastchester, NY An excavator was one foot from the unprotected edge of an 11.5-foot trench; on or about 8/18/15 |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2015-12-01 |
Current Penalty | 700.0 |
Initial Penalty | 2800.0 |
Contest Date | 2015-12-28 |
Final Order | 2016-04-11 |
Nr Instances | 2 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c): Location: Eton Place, Eastchester, a) Employees in a 11.5-foot deep excavation were not protected from cave-ins by sloping, shoring, or other protective system; on or about 8/18/15. b) Employees in a 5.6- feet deep excavation were not protected from cave-ins by sloping, shoring, or other protective system; on or about 10/21/15. |
Inspection Type | Complaint |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2014-12-22 |
Emphasis | N: TRENCH |
Case Closed | 2016-06-20 |
Related Activity
Type | Complaint |
Activity Nr | 928646 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 C02 |
Issuance Date | 2015-01-14 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Contest Date | 2015-03-12 |
Final Order | 2015-09-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees: location: 64A Sherwood Dr. on or about: 12/22/14 a) Employees were working in an excavation greater than 4 feet deep. A safe means of egress was not provided. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2015-01-14 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Contest Date | 2015-03-12 |
Final Order | 2015-09-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that that did not provide protective measures such as shoring, sloping or benching of the excavation: Location: 64A Sherwood Dr. On or about: 12/22/2014 a) Employees were working beside the unprotected wall of an excavation, 6ft 3in deep. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260701 B |
Issuance Date | 2015-01-14 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Contest Date | 2015-03-12 |
Final Order | 2015-09-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about: 12/22/14 Location: 64A Sherwood Dr. a) Employees worked in an area where reinforcing steel was not capped or covered to prevent impalement. |