334134822
|
0216000
|
2012-05-01
|
480 AUSTIN PLACE, BRONX, NY, 10455
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2012-05-01
|
Emphasis |
L: HHHT50
|
Case Closed |
2012-08-07
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2012-06-12 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use Location: Wood Shop a) Empolyees are required to wear half-face negative pressure respirators when spray painting. The employer did not write or implement a respiratory protection plan; on or about 5/1/12. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2012-06-12 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Location: Wood Shop a) Empolyees are required to wear half-face negative pressure respirators when spray painting. The employer did not medically evaluate employees before the use of respirators; on or about 5/1/12. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2012-06-12 |
Abatement Due Date |
2012-07-03 |
Current Penalty |
600.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-07-02 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Location: Worplace a) Employees work with hazardous chemicals such as but not limited to acetone and ethanol. The employer did not develop or implement a hazard communication program; on or about 5/1/12. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2012-06-12 |
Abatement Due Date |
2012-07-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-02 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees had not previously been trained about was introduced into their work area and chemical-specific information was not always available through labels and material safety data sheets Location: Worplace a) Employees work with hazardous chemicals such as but not limited to acetone and ethanol. The employer did not provide hazard communication training; on or about 5/1/12. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100107 B05 I |
Issuance Date |
2012-06-12 |
Abatement Due Date |
2012-07-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-07-02 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices were not installed to indicate or insure that the required air velocity is maintained. Location: Spray area a) The spray booth did not have a visible guage, audible alarm or a pressure activated device; on or about 5/2/12. |
|
|
334283710
|
0216000
|
2012-05-01
|
480 AUSTIN PLACE, BRONX, NY, 10455
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-05-01
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2014-03-03
|
Related Activity
Type |
Referral |
Activity Nr |
348428 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2012-06-14 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-06-26 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: Location: Establishment, Top Floor a) Electric panel controlling power to the top floor did not have electrical circuits legibly marked, thus exposing employees to struck-by hazards on or about 05/01/12. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2012-06-14 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-06-26 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Location: Establishment, Top Floor a) There were unused openings in the electric control panel that employees used to turn on the power to the garage floor, thus exposing employees to contacting energized electrical equipment on or about 05/01/12. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-06-14 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-06-26 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Location: Establishment, 1st floor a) A Delta bench grinder used by employees to sharpen chisels had a tongue guard on top that exceeded one fourth inch from the grinding wheel, thus exposing employees to struck-by hazards on or about 05/01/12. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2012-06-14 |
Current Penalty |
800.0 |
Initial Penalty |
1600.0 |
Final Order |
2012-06-26 |
Nr Instances |
1 |
Nr Exposed |
10 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: Location: Establishment, 1st floor a) A Delta bench grinder used by employees to sharpen chisels did not have a work rest, thus exposing employees to struck-by hazards on or about 05/01/12. |
|
|