Name: | J.C.D. TAPING CORP. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 14 Jan 2003 (22 years ago) |
Date of dissolution: | 22 Sep 2016 |
Entity Number: | 2856101 |
ZIP code: | 10462 |
County: | Bronx |
Place of Formation: | New York |
Address: | 2240 E. TREEMONT AVE., APT. 2B, BRONX, NY, United States, 10462 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 2240 E. TREEMONT AVE., APT. 2B, BRONX, NY, United States, 10462 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
160922000202 | 2016-09-22 | CERTIFICATE OF DISSOLUTION | 2016-09-22 |
030114000020 | 2003-01-14 | CERTIFICATE OF INCORPORATION | 2003-01-14 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
340178060 | 0215000 | 2014-08-14 | 16 MORTON STREET, NEW YORK, NY, 10014 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 989934 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260501 A02 |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 2192.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work on, had the strength and structure integrity to support employees safely: Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Workers were working from a surface that was part of the demolished stairwell system. As the employees were hoisting up a beam, the working surface collapsed and the employees were injured. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260855 D |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.855(d): Stringers of ample strength were not installed to support the flooring planks, and the ends of such stringers were not supported by floor beams or girders, and not by floor arches alone. Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees were manually hoisting materials while standing on a beam with a single piece of plywood placed on top of a partially demolished stairwell system. The work surface collapsed as the employees were working on it. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B15 |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 1800.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-03-06 |
Nr Instances | 2 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system: Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees were hoisting material on a beam on the third floor without any guardrail system, safety net or personal fall arrest system. b) Employees were assisting with hoisting operations of material while standing on a work surface on the second floor without any guardrail system, safety net or personal fall arrest system. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260503 A01 |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees were not trained in the recognition of fall hazards and procedures to eliminate or minimize the fall hazards. Two employees were working on a beam on the third floor and two more employees were on the second floor assisting the workers on the third floor and they did not recognize fall hazards. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260850 A |
Issuance Date | 2015-02-05 |
Current Penalty | 1800.0 |
Initial Penalty | 2800.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations. Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees conducting demolition activity did not have a competent person conduct and implement an engineering survey to complete the demolition. |
Citation ID | 01007 |
Citaton Type | Serious |
Standard Cited | 19261053 B13 |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 1000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees used the top or top step of a stepladder to climb up to the third floor. |
Citation ID | 01008A |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 2000.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Location: 16 Morton Street NY, NY / 3rd floor On or about: August 14, 2014 a) Employees were using an extension ladder to access the second floor, it did not extend 3 feet above the upper landing surface. |
Citation ID | 01008B |
Citaton Type | Serious |
Standard Cited | 19261053 B05 I |
Issuance Date | 2015-02-05 |
Abatement Due Date | 2015-02-18 |
Current Penalty | 0.0 |
Initial Penalty | 2000.0 |
Final Order | 2015-03-06 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support) Location: 16 Morton Street NY, NY / 1st floor On or about: August 14, 2014 a) Employees were utilizing an extension ladder to access the second floor of the project. The ladder was erected with the base too close to the access point. |
Date of last update: 30 Mar 2025
Sources: New York Secretary of State