Name: | A. SANITA CONCRETE & CONSTRUCTION, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 13 Mar 2003 (22 years ago) |
Date of dissolution: | 28 Nov 2023 |
Entity Number: | 2881876 |
ZIP code: | 11010 |
County: | Nassau |
Place of Formation: | New York |
Address: | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, United States, 11010 |
Contact Details
Phone +1 516-739-9830
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, United States, 11010 |
Name | Role | Address |
---|---|---|
AMERICO P. SANITA | Chief Executive Officer | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, United States, 11010 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1327728-DCA | Inactive | Business | 2009-08-05 | 2023-02-28 |
Start date | End date | Type | Value |
---|---|---|---|
2021-03-02 | 2024-01-18 | Address | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, 11010, USA (Type of address: Chief Executive Officer) |
2013-04-26 | 2021-03-02 | Address | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, 11010, USA (Type of address: Chief Executive Officer) |
2013-04-26 | 2024-01-18 | Address | 1145 PARK AVE, 1ST FL, FRANKLIN SQUARE, NY, 11010, USA (Type of address: Service of Process) |
2011-03-18 | 2013-04-26 | Address | 160 TULLAMORE ROAD, GARDEN CITY, NY, 11530, 1132, USA (Type of address: Principal Executive Office) |
2011-03-18 | 2013-04-26 | Address | 160 TULLAMORE ROAD, GARDEN CITY, NY, 11530, USA (Type of address: Service of Process) |
2011-03-18 | 2013-04-26 | Address | 160 TULLAMORE ROAD, GARDEN CITY, NY, 11530, 1132, USA (Type of address: Chief Executive Officer) |
2005-06-28 | 2011-03-18 | Address | 160 TULLAMORE RD, GARDEN CITY, NY, 11530, 1132, USA (Type of address: Principal Executive Office) |
2005-06-28 | 2011-03-18 | Address | 160 TULLAMORE RD, GARDEN CITY, NY, 11530, 1132, USA (Type of address: Chief Executive Officer) |
2003-03-13 | 2011-03-18 | Address | 160 TULLAMORE RD., GARDEN CITY, NY, 11530, USA (Type of address: Service of Process) |
2003-03-13 | 2023-11-28 | Shares | Share type: NO PAR VALUE, Number of shares: 200, Par value: 0 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
240118003579 | 2023-11-28 | CERTIFICATE OF DISSOLUTION-CANCELLATION | 2023-11-28 |
210302061126 | 2021-03-02 | BIENNIAL STATEMENT | 2021-03-01 |
200401060705 | 2020-04-01 | BIENNIAL STATEMENT | 2019-03-01 |
130426002504 | 2013-04-26 | BIENNIAL STATEMENT | 2013-03-01 |
110318002602 | 2011-03-18 | BIENNIAL STATEMENT | 2011-03-01 |
090226002336 | 2009-02-26 | BIENNIAL STATEMENT | 2009-03-01 |
070329003102 | 2007-03-29 | BIENNIAL STATEMENT | 2007-03-01 |
050628002912 | 2005-06-28 | BIENNIAL STATEMENT | 2005-03-01 |
030313000520 | 2003-03-13 | CERTIFICATE OF INCORPORATION | 2003-03-13 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3256387 | RENEWAL | INVOICED | 2020-11-12 | 100 | Home Improvement Contractor License Renewal Fee |
3256386 | TRUSTFUNDHIC | INVOICED | 2020-11-12 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2905055 | TRUSTFUNDHIC | INVOICED | 2018-10-05 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2905056 | RENEWAL | INVOICED | 2018-10-05 | 100 | Home Improvement Contractor License Renewal Fee |
2563427 | TRUSTFUNDHIC | INVOICED | 2017-02-28 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2563428 | RENEWAL | INVOICED | 2017-02-28 | 100 | Home Improvement Contractor License Renewal Fee |
2298674 | LICENSEDOC10 | INVOICED | 2016-03-14 | 10 | License Document Replacement |
1997943 | TRUSTFUNDHIC | INVOICED | 2015-02-26 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1997944 | RENEWAL | INVOICED | 2015-02-26 | 100 | Home Improvement Contractor License Renewal Fee |
970104 | TRUSTFUNDHIC | INVOICED | 2013-05-20 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343960977 | 0215000 | 2019-04-25 | 29 STANTON ROAD, BROOKLYN, NY, 11235 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19261052 C01 I |
Issuance Date | 2019-07-10 |
Current Penalty | 2400.0 |
Initial Penalty | 3789.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a 15 steps 10 feet tall stairway. The stairway was not equipped with at least one handrail. Employees were exposed to fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261052 C01 II |
Issuance Date | 2019-07-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a 15 steps 10 feet tall stairway. The stairway was not equipped with a stairrail system along each unprotected side or edge. Employees were exposed to fall hazard. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19261052 C12 |
Issuance Date | 2019-07-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a stairway landing which did not have any guardrails along the open sides. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2019-04-25 |
Emphasis | L: LOCALTARG, P: LOCALTARG |
Case Closed | 2019-07-22 |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19261052 C01 I |
Issuance Date | 2019-07-10 |
Current Penalty | 2400.0 |
Initial Penalty | 3789.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a 17 steps 10.5 feet tall stairway. The stairway was not equipped with at least one handrail. Employees were exposed to fall hazard. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261052 C01 II |
Issuance Date | 2019-07-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a 17 steps 10.5 feet tall stairway. The stairway was not equipped with a stairrail system along each unprotected side or edge. Employees were exposed to fall hazard. |
Citation ID | 01001C |
Citaton Type | Serious |
Standard Cited | 19261052 C12 |
Issuance Date | 2019-07-10 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2019-07-18 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926. Location: a) On the entrance stairway of the jobsite: On or about 04/25/19, employees were pouring concrete on a stairway landing which did no have any guardrails on the open sides. |
Inspection Type | Complaint |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2012-06-20 |
Emphasis | L: FALL |
Case Closed | 2013-05-23 |
Related Activity
Type | Complaint |
Activity Nr | 402410 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260651 K02 |
Issuance Date | 2012-10-03 |
Abatement Due Date | 2012-10-11 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-11-09 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.651(k)(2): Where the competent person finds evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees shall be removed from the hazardous area until the necessary precautions have been taken to ensure their safety. Site: 110-120 East 76th Street New York, NY On or about 6/20/12 a) When the employer found evidence of an unsafe condition due to the excavation been over 5 feet deep, the condition was not corrected. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260652 A01 |
Issuance Date | 2012-10-03 |
Abatement Due Date | 2012-10-11 |
Current Penalty | 1400.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-11-09 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.652(a)(1): Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with this standard. Site: 110-120 East 7th Street New York, NY On or about 6/20/12 a) The excavation was beyond 5 feet deep and was not provided with shoring to protect employees from cave-ins. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-10-03 |
Abatement Due Date | 2012-10-11 |
Current Penalty | 800.0 |
Initial Penalty | 1600.0 |
Final Order | 2012-11-09 |
Nr Instances | 1 |
Nr Exposed | 6 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Site: 110-120 East 76th Street New York, NY On or about 6/20/12 a) The ladder use to access the bottom of the employees work area did not extend 3 feet above the landing surface. |