Search icon

KENSINGTON HOMES LLC

Company Details

Name: KENSINGTON HOMES LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Inactive
Date of registration: 16 Apr 2003 (22 years ago)
Date of dissolution: 07 Jul 2022
Entity Number: 2895598
ZIP code: 11021
County: Nassau
Place of Formation: New York
Address: 1 LINDEN PLAZA, STE 210, GREAT NECK, NY, United States, 11021

DOS Process Agent

Name Role Address
KENSINGTON HOMES LLC DOS Process Agent 1 LINDEN PLAZA, STE 210, GREAT NECK, NY, United States, 11021

History

Start date End date Type Value
2017-08-03 2022-07-07 Address 1 LINDEN PLAZA, STE 210, GREAT NECK, NY, 11021, USA (Type of address: Service of Process)
2009-04-10 2017-08-03 Address 8 BOND ST, STE 302, GREAT NECK, NY, 11021, USA (Type of address: Service of Process)
2007-05-18 2009-04-10 Address 756 MIDDLE NECK ROAD / 2ND FL, GREAT NECK, NY, 11024, USA (Type of address: Service of Process)
2005-04-14 2007-05-18 Address 14 BOND ST, SUITE 422, GREAT NECK, NY, 11021, USA (Type of address: Service of Process)
2003-04-16 2005-04-14 Address 17 EAST 48TH STREET, NEW YORK, NY, 10017, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
220707000114 2022-01-24 CERTIFICATE OF DISSOLUTION-CANCELLATION 2022-01-24
220105000697 2022-01-05 BIENNIAL STATEMENT 2022-01-05
191114060361 2019-11-14 BIENNIAL STATEMENT 2019-04-01
170803002011 2017-08-03 BIENNIAL STATEMENT 2017-04-01
110902002654 2011-09-02 BIENNIAL STATEMENT 2011-04-01
090410002568 2009-04-10 BIENNIAL STATEMENT 2009-04-01
070518002471 2007-05-18 BIENNIAL STATEMENT 2007-04-01
050414002165 2005-04-14 BIENNIAL STATEMENT 2005-04-01
030416000656 2003-04-16 ARTICLES OF ORGANIZATION 2003-04-16

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340138049 0214700 2014-12-15 11 CHERRY LANE, KINGS POINT, NY, 11024
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2014-12-15
Emphasis L: FALL
Case Closed 2016-10-19

Related Activity

Type Inspection
Activity Nr 1013830
Safety Yes
Type Referral
Activity Nr 927078
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. The employees walking and working under the overhead brick work were exposed to being struck by falling bricks and other materials; on or about 12/12/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. Employees were working from areas of the scaffold which were not fully planked; on or about 12/12/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 B05 II
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1250.0
Initial Penalty 2800.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end. a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. An employee was accessing an area of the scaffold by using a plank that was not supported on one end; 12/12/14. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 E05 I
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1250.0
Initial Penalty 2800.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. An employee was accessing an area of the scaffold by using a plank that was missing guardrails; on or about 12/12/14. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. Employees were working from areas of the scaffold without a means of fall protection; on or about 12/12/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260451 H02 II
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toe boards. a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from a fabricated frame scaffold. The scaffold did not have toe boards installed; on or about 12/12/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01007
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2015-05-29
Abatement Due Date 2015-06-04
Current Penalty 1000.0
Initial Penalty 2000.0
Contest Date 2015-06-18
Final Order 2015-08-31
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Worksite, 11 Cherry Lane Kings Point NY - Employees were installing brick on a residential home while working from the roof of the home. The employees were not provided with a means of fall protection and were exposed to falling up to approximately 15ft to the ground below; on or about 12/12/14. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.

Date of last update: 30 Mar 2025