Search icon

PANE STONE CONSTRUCTION INC.

Company Details

Name: PANE STONE CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 18 Apr 2003 (22 years ago)
Date of dissolution: 30 Oct 2014
Entity Number: 2896629
ZIP code: 11354
County: Queens
Place of Formation: New York
Address: 35-06 FARRINGTON STREET, FLUSHING, NY, United States, 11354

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 35-06 FARRINGTON STREET, FLUSHING, NY, United States, 11354

Filings

Filing Number Date Filed Type Effective Date
141030000362 2014-10-30 CERTIFICATE OF DISSOLUTION 2014-10-30
030418000695 2003-04-18 CERTIFICATE OF INCORPORATION 2003-04-18

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2014-07-23 No data 146 STREET, FROM STREET 32 AVENUE TO STREET 33 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation new curb installed
2014-04-29 No data KENMARE STREET, FROM STREET ELIZABETH STREET TO STREET MOTT STREET No data Street Construction Inspections: Post-Audit Department of Transportation no defects. steel face
2014-04-21 No data ELIZABETH STREET, FROM STREET BROOME STREET TO STREET KENMARE STREET No data Street Construction Inspections: Post-Audit Department of Transportation no defects found upon inspection of restoration.
2014-04-01 No data 33 STREET, FROM STREET 3 AVENUE TO STREET 4 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation s/w
2013-10-14 No data ELIZABETH STREET, FROM STREET BROOME STREET TO STREET KENMARE STREET No data Street Construction Inspections: Post-Audit Department of Transportation pass curb
2013-10-14 No data KENMARE STREET, FROM STREET ELIZABETH STREET TO STREET MOTT STREET No data Street Construction Inspections: Post-Audit Department of Transportation pass s/w
2013-10-14 No data MOTT STREET, FROM STREET GRAND STREET TO STREET HESTER STREET No data Street Construction Inspections: Post-Audit Department of Transportation pass curb
2013-08-03 No data 146 STREET, FROM STREET 32 AVENUE TO STREET 33 AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation Concrete curb
2013-07-05 No data 249 STREET, FROM STREET 89 AVENUE TO STREET JAMAICA AVENUE No data Street Construction Inspections: Post-Audit Department of Transportation steel face & drop
2013-06-15 No data 4 AVENUE, FROM STREET 25 STREET TO STREET 26 STREET No data Street Construction Inspections: Post-Audit Department of Transportation curb ok

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339183386 0215600 2013-07-09 39-16 COLLEGE POINT BLVD., FLUSHING, NY, 11354
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2013-07-09
Case Closed 2013-09-16

Related Activity

Type Inspection
Activity Nr 280142
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Repeat
Standard Cited 19260404 F06
Issuance Date 2013-08-30
Current Penalty 2200.0
Initial Penalty 4400.0
Final Order 2013-09-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) At the worksite - A Hilti TE7 Rotary Hammer used to drill holes in concrete was attached to an extension cord that did not have a ground prong; on or about 03/02/12. Pane Stone Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.404(f)(6), which was contained in OSHA inspection number 280142, citation number 01, item number 02 and was affirmed as a final order on 07/03/13, with respect to a workplace located at 39-16 College Point Blvd.
Citation ID 01001B
Citaton Type Repeat
Standard Cited 19260405 B02
Issuance Date 2013-08-30
Current Penalty 0.0
Initial Penalty 4400.0
Final Order 2013-09-05
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: (a) At the worksite - A service panel used to power equipment at the site had an open slot for a circuit breaker that was not covered; 07/09/13. The Pane Stone Construction was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.405(b)(2), which was contained in OSHA inspection number 280142, citation number 01, item number 03 and was affirmed as a final order on 07/03/13, with respect to a workplace located at 39-16 College Point Blvd.
332801422 0215600 2012-03-02 39-16 COLLEGE POINT BLVD., FLUSHING, NY, 11354
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2012-03-02
Emphasis N: CTARGET
Case Closed 2014-07-22

Related Activity

Type Complaint
Activity Nr 216703
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 B02
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) At the worksite - An outlet designed to be permanently mounted on or in a wall, was used to power a welder. The outlet was ratedat 240v 30Amps; on or about 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2013-07-09
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: (a) At the worksite - A Makita Drill and Saws-all used to drill and cut wood did not have a ground prong on the plug at the end of the extension cord used to power the equipment; on or about 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 3000.0
Initial Penalty 3000.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers: (a) At the worksite - A service panel used to power equipment at the site had open slots for circuit breakers that were not covered; 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 A02
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-07-10
Nr Instances 3
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use: a) At the work site - Several wood job made ladders were constructed with rungs that were not parallel, level and uniformly spaced; on or 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 19
Citation ID 01004B
Citaton Type Serious
Standard Cited 19261053 A03 I
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 2
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(a)(3)(i): Rungs, cleats, and steps of portable ladders (except as provided below) and fixed ladders (including individual-rung/step ladders) shall be spaced not less than 10 inches (25 cm) apart, nor more than 14 inches (36 cm) apart, as measured between center lines of the rungs, cleats and steps. a) At the work site - Wood job-made ladders had rungs that were spaced 17 inches and 15 inches apart; on or about 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01004C
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-06-12
Abatement Due Date 2012-06-13
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 3
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access and/or was not secured at its top to a rigid support: (a) At the worksite - Several wood job-made ladders used to access the the top of the foundation from ground level were not secured and did not extend 3 feet above the upper landing; on or about 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
Citation ID 01004D
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2012-06-12
Abatement Due Date 2012-07-03
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 5
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) At the worksite - Employees used wood job made ladders that were not secured, had rungs that were not parallel and uniformly spaced and had rungs that were spaced too far apart; on or about 03/02/12. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN THE ACCORDANCE WITH 29 CFR 1903.19
315506790 0215000 2011-04-27 139 33RD STREET, BROOKLYN, NY, 11232
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2011-04-27
Emphasis L: FALL
Case Closed 2011-08-09

Related Activity

Type Complaint
Activity Nr 208279893
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2011-07-25
Abatement Due Date 2011-07-28
Current Penalty 2400.0
Initial Penalty 2400.0
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 05
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 A02 IIE
Issuance Date 2011-07-25
Abatement Due Date 2011-08-04
Current Penalty 2400.0
Initial Penalty 2400.0
Nr Instances 1
Nr Exposed 5
Gravity 05
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2011-07-25
Abatement Due Date 2011-08-04
Current Penalty 2400.0
Initial Penalty 2400.0
Nr Instances 1
Nr Exposed 5
Gravity 05
313883134 0215000 2009-11-09 50 WEST 36TH STREET, NEW YORK, NY, 10018
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2009-11-09
Emphasis L: CONSTLOC
Case Closed 2009-11-09
313586349 0215000 2009-07-22 536 39TH STREET, BROOKLYN, NY, 11232
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2009-07-22
Emphasis L: FALL, S: RESIDENTIAL CONSTR
Case Closed 2010-03-10

Related Activity

Type Complaint
Activity Nr 207269598
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2009-09-29
Abatement Due Date 2009-10-09
Current Penalty 600.0
Initial Penalty 600.0
Contest Date 2009-10-23
Final Order 2010-02-16
Nr Instances 1
Nr Exposed 3
Gravity 02
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B06
Issuance Date 2009-09-29
Abatement Due Date 2009-10-09
Current Penalty 1500.0
Initial Penalty 1500.0
Contest Date 2009-10-23
Final Order 2010-02-16
Nr Instances 1
Nr Exposed 3
Gravity 10
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2009-09-29
Abatement Due Date 2009-10-09
Current Penalty 750.0
Initial Penalty 750.0
Contest Date 2009-10-23
Final Order 2010-02-16
Nr Instances 2
Nr Exposed 3
Gravity 03
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2009-09-29
Abatement Due Date 2009-10-09
Current Penalty 750.0
Initial Penalty 750.0
Contest Date 2009-10-23
Final Order 2010-02-16
Nr Instances 1
Nr Exposed 3
Gravity 03
Citation ID 01005
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2009-09-29
Abatement Due Date 2009-10-19
Current Penalty 750.0
Initial Penalty 750.0
Contest Date 2009-10-23
Final Order 2010-02-16
Nr Instances 2
Nr Exposed 3
Gravity 03
106934631 0215000 1993-08-17 159 MOTT STREET, NEW YORK, NY, 10013
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 1993-08-17
Case Closed 1994-01-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260059 G08
Issuance Date 1993-09-14
Abatement Due Date 1993-09-20
Current Penalty 580.0
Initial Penalty 900.0
Nr Instances 1
Nr Exposed 2
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260405 A02 IIE
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 780.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 J01 II
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 780.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01004
Citaton Type Serious
Standard Cited 19260500 C01
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 1950.0
Initial Penalty 3000.0
Nr Instances 2
Nr Exposed 2
Gravity 10
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 B02
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 1950.0
Initial Penalty 3000.0
Nr Instances 1
Nr Exposed 2
Gravity 10
Citation ID 01006
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 780.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260500 D01
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 3900.0
Initial Penalty 6000.0
Nr Instances 2
Nr Exposed 2
Gravity 10
Citation ID 02002
Citaton Type Repeat
Standard Cited 19030002 A01
Issuance Date 1993-09-14
Abatement Due Date 1993-09-17
Current Penalty 780.0
Initial Penalty 1200.0
Nr Instances 1
Nr Exposed 2
Gravity 03

Date of last update: 30 Mar 2025