Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-01-30
|
Emphasis |
L: GUTREH, P: CTARGET, N: CTARGET
|
Case Closed |
2015-06-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1023847 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1024087 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1023948 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260153 O |
Issuance Date |
2015-02-12 |
Abatement Due Date |
2015-02-23 |
Current Penalty |
400.0 |
Initial Penalty |
1600.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.153(o): When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: a) West side of building, on or about 1-30-15: Employees were walking/driving in an area immediately adjacent to a 500 gallon Liquefied Petroleum Gas (LPG) tank that was not protected against vehicular/accidental contact. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260153 L |
Issuance Date |
2015-02-12 |
Abatement Due Date |
2015-02-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.153(l): LP-Gas storage locations were not provided with at least one approved portable fire extinguisher having a rating of not less than 20-B:C: a) West side of building, on or about 1-30-15: Employees were walking/driving in an area immediately adjacent to an unprotected 500 gallon Liquefied Petroleum Gas (LPG) tank, with no fire extinguisher in the area. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2015-02-12 |
Abatement Due Date |
2015-02-23 |
Current Penalty |
650.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a)First floor, on or about 1-30-15: Employees were ripping framing lumber on a table saw that was not equipped with a spreader. b) First floor, on or about 1-30-15: Employees were ripping framing lumber on a table saw that was not equipped with non kick-back fingers or dogs. c) First floor, on or about 1-23-15: Employees were ripping framing lumber on a table saw that was not equipped with a magnetic switch or anti-restart device. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2015-02-12 |
Abatement Due Date |
2015-02-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) First floor, on or about 1-30-15: Employees were ripping framing lumber on a table saw that was not equipped with a hood guard that automatically adjusts to completely enclose the saw blade which protrudes above the table top and/or the piece of material that is being cut. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260403 I02 |
Issuance Date |
2015-02-12 |
Current Penalty |
650.0 |
Initial Penalty |
2000.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(2): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures: a) Second floor, on or about 1-30-15: Employees were working in the vicinity of an energized power panel that had a cardboard cover on it. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2015-02-12 |
Abatement Due Date |
2015-02-23 |
Current Penalty |
300.0 |
Initial Penalty |
1200.0 |
Contest Date |
2015-03-06 |
Final Order |
2015-06-08 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) First floor to basement, on or about 1-30-15: Employees were using a closed stairway without a hand rail on one side of the stairs, exposing the employees to a fall hazard of up to 5 feet 4 inches. ABATEMENT CERTIFICATION IS REUIRED FOR THIS ITEM |
|
|