344073994
|
0215000
|
2019-06-11
|
2076 86TH ST., BROOKLYN, NY, 11214
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-06-11
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2022-06-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1407437 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2019-12-03 |
Current Penalty |
1342.0 |
Initial Penalty |
2842.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 2nd floor: Employees used an electric powered welding machine to weld metal decks. The welding machine was connected to an extension cord, which was routed directly to the circuit breaker of the next door building and was not provided with a ground fault circuit interrupter. On or about 06/11/19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2019-12-03 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. a) 2nd floor: Employees used an electric powered welding machine to weld metal decks. The welding machine was connected to an extension cord, which was not provided strain relief to its outlet. On or about 06/11/19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260416 E01 |
Issuance Date |
2019-12-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. a) 2nd floor: Employees used an electric powered welding machine to weld metal decks. The welding machine was connected to an extension cord, which was worn and frayed with damaged insulation. On or about 06/11/19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2019-12-03 |
Current Penalty |
1342.0 |
Initial Penalty |
2842.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports. a) 2nd floor, south side: An employee was working on the 2nd tier platform of a 2-tier-high supported scaffold. The work platform was not fully planked or decked between the front uprights and the guardrail supports. On or about 06/11/19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2019-12-03 |
Current Penalty |
1342.0 |
Initial Penalty |
2842.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) 2nd floor, south side: Employees climbed the frames and cross braces of a 2-tier-high supported scaffold to access the 2nd tier scaffold platform and the roof level to do welding work. On or about 06/11/19. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2019-12-03 |
Current Penalty |
2290.0 |
Initial Penalty |
3978.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) 2nd floor, south side: An employee was working on the 2nd tier platform of a 2-tier-high supported scaffold, and was not protected from falling to lower levels by the use of fall protection systems. The employee was exposed to falling approximately 12 feet. On or about 06/11/19. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19261051 A03 |
Issuance Date |
2019-12-03 |
Current Penalty |
1342.0 |
Initial Penalty |
2842.0 |
Final Order |
2020-03-11 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1051(a)(3): A building or structure had only one point of access between levels, which was not kept clear to permit free passage of employees. a) 2nd floor: The 2nd floor had only one point of access from the 1st floor through an extension ladder. The access at the top of the ladder on the 2nd floor was not kept clear and was blocked by wire cable guardrails. On or about 06/11/19. |
|
|
341706109
|
0215000
|
2016-08-15
|
221 W. 17TH ST., NEW YORK, NY, 10011
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-08-15
|
Emphasis |
L: FALL, L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2020-12-07
|
Related Activity
Type |
Inspection |
Activity Nr |
1170549 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 I03 |
Issuance Date |
2016-12-06 |
Current Penalty |
3207.0 |
Initial Penalty |
3207.0 |
Final Order |
2017-02-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(i)(3): All covers were not secured when installed so as to prevent accidental displacement by the wind, equipment, or employees. a. 221 West 17th Street, New York, NY - 3rd Level The general contractor did not provide secure covers for an 18 inch by 40-foot floor hole. Sub-contractor employees engaged in the installation of steel wall support rakers were not provided protection from falls with the secure installation of floor covers. Violation observed on or about August 15, 2016 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260502 I04 |
Issuance Date |
2016-12-06 |
Current Penalty |
3207.0 |
Initial Penalty |
3207.0 |
Final Order |
2017-02-16 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(i)(4): All covers were not color coded or marked with the word "HOLE" or "COVER" to provide warning of the hazard: a. 221 West 17th Street, New York, NY - 2rd Level The employer did not ensure secure covers for an 18 inch by 40-foot floor hole were marked to provide a warning of the hazard. Employees and Sub-contractor employees engaged in the rehab of a commercial property were not provided warning of floor holes by use of color coded or marked "Hole" or "Cover" on the wood covers. Violation observed on or about August 15, 2016 |
|
|
307668038
|
0216000
|
2005-09-30
|
115 HENWOOD PLACE, BRONX, NY, 10453
|
|
Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2005-09-30
|
Emphasis |
L: FALL
|
Case Closed |
2006-08-25
|
Related Activity
Type |
Complaint |
Activity Nr |
205175029 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260350 A09 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Current Penalty |
445.0 |
Initial Penalty |
600.0 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
10 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260350 A10 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260760 A01 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Current Penalty |
1110.0 |
Initial Penalty |
1500.0 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 II |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Current Penalty |
555.0 |
Initial Penalty |
750.0 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Current Penalty |
445.0 |
Initial Penalty |
600.0 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Current Penalty |
445.0 |
Initial Penalty |
600.0 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19261053 B09 |
Issuance Date |
2005-10-11 |
Abatement Due Date |
2005-10-14 |
Contest Date |
2005-11-18 |
Final Order |
2006-03-24 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
|