Search icon

FORGE HEATING & AIR CONDITIONING CORP.

Company Details

Name: FORGE HEATING & AIR CONDITIONING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 30 Mar 1970 (55 years ago)
Entity Number: 290977
ZIP code: 11959
County: Nassau
Place of Formation: New York
Address: 2 QUOGUE PLAZA TRAIL, PO BOX 922, QUOGUE, NY, United States, 11959

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
RUSSELL H. STREEKER, III Chief Executive Officer 2 QUOGUE PLAZA TRAIL, PO BOX 922, QUOGUE, NY, United States, 11959

DOS Process Agent

Name Role Address
RUSSELL H. STREEKER, III DOS Process Agent 2 QUOGUE PLAZA TRAIL, PO BOX 922, QUOGUE, NY, United States, 11959

History

Start date End date Type Value
2002-03-06 2004-03-22 Address 38 E ARGONNE RD, HAMPTON BAYS, NY, 11946, USA (Type of address: Principal Executive Office)
1995-04-24 2004-03-22 Address 38 E. ARGONE RD, HAMPTON BAYS, NY, 11946, USA (Type of address: Chief Executive Officer)
1995-04-24 2002-03-06 Address P.O. BOX 791, 38 E. ARGONNE RD, HAMPTON BAYS, NY, 11946, USA (Type of address: Principal Executive Office)
1995-04-24 2004-03-22 Address 38 E. ARGONNE RD., HAMPTON BAYS, NY, 11946, USA (Type of address: Service of Process)
1970-03-30 2023-12-27 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
1970-03-30 1995-04-24 Address FORGE RD., CALVERTON, NY, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
20080703035 2008-07-03 ASSUMED NAME CORP INITIAL FILING 2008-07-03
080310003028 2008-03-10 BIENNIAL STATEMENT 2008-03-01
060329002283 2006-03-29 BIENNIAL STATEMENT 2006-03-01
040322002246 2004-03-22 BIENNIAL STATEMENT 2004-03-01
020306002042 2002-03-06 BIENNIAL STATEMENT 2002-03-01
000327002755 2000-03-27 BIENNIAL STATEMENT 2000-03-01
960805002536 1996-08-05 BIENNIAL STATEMENT 1996-03-01
950424002066 1995-04-24 BIENNIAL STATEMENT 1993-03-01
823851-4 1970-03-30 CERTIFICATE OF INCORPORATION 1970-03-30

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346523863 0214700 2023-02-23 161 DOWNS PATH, SOUTHAMPTON, NY, 11968
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2023-02-23
Emphasis L: FALL, P: FALL
Case Closed 2024-09-12

Related Activity

Type Referral
Activity Nr 2002123
Safety Yes
Health Yes
Type Inspection
Activity Nr 1653087
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2023-07-24
Current Penalty 4050.0
Initial Penalty 4465.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 On or about February 13th, 2023. An employee installing HVAC system equipment on top of a roof of a 2-story residential home utilized a 10-feet A-frame ladder to access area. The employee was walking and working directly on the edge of the roof and was not utilizing a means of fall protection. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2023-07-24
Abatement Due Date 2023-08-03
Current Penalty 0.0
Initial Penalty 3572.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 On or about February 13th, 2023, Employee was working directly on the edge of a patio roof for a residential home. The employee was not trained to recognize hazards associated with falls. Note: ABATEMENT DOCUMENTATION IS REQUIRED PURSUANT TO 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2023-07-24
Current Penalty 4050.0
Initial Penalty 4465.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 On or about February 13th, 2023, an employee was exposed to fall hazards, while accessing the roof of a two story residential home. The employee was using a 10ft A frame ladder that did not extend 3ft above the roof edge. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2023-07-24
Current Penalty 0.0
Initial Penalty 4465.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 On or about February 13th, 2023, an employee were accessing the roof of an two story residential home from the back patio by leaning a 10-foot A frame ladder that was not fully deployed against the edge of the roof of the two story residential home Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01005C
Citaton Type Serious
Standard Cited 19261060 A01 II
Issuance Date 2023-07-24
Abatement Due Date 2023-08-17
Current Penalty 0.0
Initial Penalty 2678.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a)(1)(ii): The employer did not ensure that each employee using ladders and/or stairways had been trained by a competent person in the correct procedures for erecting, maintaining, and disassembling the fall protection systems to be used. a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 On or about February 13th, 2023, An employee installing HVAC system equipment on top of a roof of a 2-story residential home utilized a 10-feet A-frame ladder to access area and fell approximately 21-feet to the ground below. The employer did not ensured that employees received training in the proper use of ladders by a competent person. Note: Abatement documentation is required pursuant to 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19040039 A02
Issuance Date 2023-07-24
Current Penalty 4000.0
Initial Penalty 4465.0
Contest Date 2023-08-25
Final Order 2024-04-04
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours. a) Worksite, Back Patio of Residential Building: 161 Downs Path, Suffolk, NY, 11968 A) On or about February 13th, 2023. Employer failed to report an inpatient hospitalization within 24 hours of the incident. OSHA was notified of the incident by the employer on February 23rd, 2023. ABATEMENT CERTIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19

Date of last update: 18 Mar 2025