Search icon

ACQUEST CONSTRUCTION, LLC

Company Details

Name: ACQUEST CONSTRUCTION, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 15 Oct 2003 (22 years ago)
Entity Number: 2965137
ZIP code: 14221
County: Erie
Place of Formation: New York
Address: 5554 Main St, WILLIAMSVILLE, NY, United States, 14221

DOS Process Agent

Name Role Address
ACQUEST CONSTRUCTION LLC DOS Process Agent 5554 Main St, WILLIAMSVILLE, NY, United States, 14221

History

Start date End date Type Value
2011-10-27 2023-11-29 Address 80 CURTWRITE DRIVE STE 5, WILLIAMSVILLE, NY, 14221, USA (Type of address: Service of Process)
2007-11-21 2011-10-27 Address 80 CARTWRITE DRIVE STE 5, WILLIAMSVILLE, NY, 14221, USA (Type of address: Service of Process)
2005-12-14 2007-11-21 Address 665 MAIN ST, STE 300, BUFFALO, NY, 14203, USA (Type of address: Service of Process)
2003-10-15 2005-12-14 Address 700 GUARANTY BUILDING, 28 CHURCH STREET, BUFFALO, NY, 14202, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
231129016957 2023-11-29 BIENNIAL STATEMENT 2023-10-01
220915003148 2022-09-15 BIENNIAL STATEMENT 2021-10-01
131205002178 2013-12-05 BIENNIAL STATEMENT 2013-10-01
111027002086 2011-10-27 BIENNIAL STATEMENT 2011-10-01
091106002375 2009-11-06 BIENNIAL STATEMENT 2009-10-01
071121002141 2007-11-21 BIENNIAL STATEMENT 2007-10-01
051214002411 2005-12-14 BIENNIAL STATEMENT 2005-10-01
040322000527 2004-03-22 AFFIDAVIT OF PUBLICATION 2004-03-22
040322000525 2004-03-22 AFFIDAVIT OF PUBLICATION 2004-03-22
031015000170 2003-10-15 ARTICLES OF ORGANIZATION 2003-10-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346426554 0215800 2023-01-09 100 NORTHERN CONCOURSE, SYRACUSE, NY, 13212
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2023-01-09
Emphasis N: TRENCH
Case Closed 2023-05-19

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260153 O
Issuance Date 2023-05-05
Current Penalty 2008.5
Initial Penalty 2678.0
Final Order 2023-05-17
Nr Instances 1
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.153(o):When damage to LP-Gas systems from vehicular traffic was a possibility, precautions against such damage were not taken: a) 100 Northern Concourse, Syracuse, NY 13212: On or about 1/9/2023, the employer did not protected an above ground liquified petroleum gas tank (LPG) against collision hazards from vehicular traffic including but not limited to JLG 944E-42 Lull traffic to retrieve lumber and pallets of bricks or to lift materials into the dumpster for disposal.
342352333 0213600 2017-05-23 408 MILL STREET, WILLIAMSVILLE, NY, 14221
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2017-05-23
Emphasis L: FALL, P: FALL
Case Closed 2017-06-26

Violation Items

Citation ID 01001
Citaton Type Other
Standard Cited 19261052 C01 I
Issuance Date 2017-05-26
Current Penalty 1570.0
Initial Penalty 1570.0
Final Order 2017-06-14
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about 5/23/17, at the site of Williamsville, NY. A total of three stairways to the second floor, one with 14 riser steps; two with 10 riser steps, lacked at least one hand rail. NO ABATEMENT CERTIFICATION REQUIRED
342059771 0213600 2017-01-11 408 MILL STREET, WILLIAMSVILLE, NY, 14221
Inspection Type Unprog Rel
Scope Complete
Safety/Health Safety
Close Conference 2017-06-27
Emphasis L: FALL
Case Closed 2018-06-04

Related Activity

Type Inspection
Activity Nr 1206031
Safety Yes
Type Inspection
Activity Nr 1206005
Safety Yes
Type Inspection
Activity Nr 1240966
Safety Yes
Type Referral
Activity Nr 1177382
Safety Yes
Type Inspection
Activity Nr 1206185
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Other
Standard Cited 19260502 B03
Issuance Date 2017-07-06
Current Penalty 2000.0
Initial Penalty 3803.0
Contest Date 2017-07-24
Final Order 2018-03-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east side of the unit 313 deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATION REQUIRED
Citation ID 01001B
Citaton Type Other
Standard Cited 19260502 B05
Issuance Date 2017-07-06
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2017-07-24
Final Order 2018-03-08
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members shall be capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward direction at any point along the midrail or other member: a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east side of the unit 313 deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATION REQUIRED