346965890
|
0213600
|
2023-09-08
|
55 EXCHANGE BLVD, ROCHESTER, NY, 14614
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-09-29
|
Emphasis |
N: LEAD
|
Case Closed |
2024-11-26
|
Related Activity
Type |
Complaint |
Activity Nr |
2058741 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260062 D01 I |
Issuance Date |
2023-09-29 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
0.0 |
Initial Penalty |
4687.0 |
Contest Date |
2023-09-29 |
Final Order |
2024-10-15 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(d)(1)(i):Each employer who had a workplace or operation covered by 29 CFR 1926.62 did not initially determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30 mg/m3) calculated as an 8-hour time-weighted average (TWA): a) 55 Exchange Blvd., Rochester, NY - On or about and prior to 9/08/2023, employees were working in an area where paint chips contained between 0.0046%-0.963% lead. The employer did not determine if any employee was exposed to lead at or above the action level of 30 micrograms per cubic meter of air (30ug/m3) calculated as an 8-hour time-weighted average (TWA). ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260062 L01 I |
Issuance Date |
2023-09-29 |
Abatement Due Date |
2023-11-01 |
Current Penalty |
1500.0 |
Initial Penalty |
0.0 |
Contest Date |
2023-09-29 |
Final Order |
2024-10-15 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.62(l)(1)(i): 29 CFR 1926.62(l)(1)(i): The employer did not include lead in the program established to comply with the Hazard Communication Standard (HCS) (29 CFR 1910.1200), ensure that each employee had access to labels on containers of lead and�safety data sheets, was trained in accordance with the provisions of the Hazard Communication standard and 29 CFR 1926.62(l), and ensure that all the following hazards were addressed: Reproductive/developmental toxicity; central nervous system effects; kidney effects; blood effects; and acute toxicity effects: a) 55 Exchange Blvd., Rochester, NY - On or about and prior to 9/08/2023, employees working in an area where paint chips contained between (0.0046%-0.963% lead). The employer did not include lead in the program established to comply with the Hazard Communication Standard (HCS) (29 CFR 1910.1200): ensure that each employee had access to safety data sheets; was trained in accordance with the provisions of the Hazard Communication Standard and 29 CFR 1926.62(l); and ensure that all the following hazards were addressed: reproductive/developmental toxicity; central nervous system effects; kidney effects; blood effects; and acute toxicity effects. ABATEMENT CERTIFICATION REQUIRED |
|
|
345709711
|
0213600
|
2022-01-04
|
899 CULVER ROAD, ROCHESTER, NY, 14609
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-01-04
|
Emphasis |
L: GUTREH, P: GUTREH
|
Case Closed |
2023-09-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260403 I01 II |
Issuance Date |
2022-01-28 |
Current Penalty |
0.0 |
Initial Penalty |
3143.0 |
Contest Date |
2022-02-08 |
Final Order |
2022-09-22 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(i)(1)(ii):Working space about electric equipment operating at 600 volts, nominal, or less was used for storage: a) On or about 01/04/2022, at the Culver Manor, undergoing rehabilitation and located at 899 Culver Road in Rochester, New York, the employer did not ensure that electrical equipment was free of recognized hazards. Safe access to the working space in front of an electrical panel was obstructed by the storage of a ladder. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 A02 II I |
Issuance Date |
2022-01-28 |
Current Penalty |
0.0 |
Initial Penalty |
3143.0 |
Contest Date |
2022-02-08 |
Final Order |
2022-09-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(2)(ii)(I):Flexible cords and cables used for temporary wiring were not protected from damage: a) On or about 01/04/2022, at the Culver Manor, undergoing rehabilitation and located at 899 Culver Road in Rochester, New York, the employer did not enforce safe wiring practices to protect electrical cords from damage. An electrical cord was suspended by a screw creating a sharp edge against the outer jacket of the cord. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
345261960
|
0213600
|
2021-04-20
|
2250 OLD UNION ROAD, CHEEKTOWAGA, NY, 14227
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-04-20
|
Emphasis |
P: CTARGET, N: CTARGET
|
Case Closed |
2023-09-29
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260405 B01 |
Issuance Date |
2021-06-04 |
Current Penalty |
0.0 |
Initial Penalty |
3481.0 |
Contest Date |
2021-06-23 |
Final Order |
2022-03-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(1):Unused openings in cabinets, boxes, and fittings were not effectively closed: a) On or about 4/20/2021, at Panel B area of the site, Cheektowaga, NY. Unused opening of 1-inch diameter, at bottom of the panel, was not closed. Panel B is of 100 Amp and 240 Volt. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260403 H |
Issuance Date |
2021-06-04 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-06-23 |
Final Order |
2022-03-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(h):Each service, feeder, and branch circuit was not legibly marked at its disconnecting means or overcurrent device to indicate its purpose, nor located and arranged so that the purpose was evident: a) On or about 4/20/2021, at Panel B area of the site, Cheektowaga, NY. Panel B, of 100Ammp and 240 Volt, lacked the panel directory to indicate the purpose of overcurrent devices. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
340566967
|
0213600
|
2015-04-10
|
3865 WEST HENRIETTA ROAD, ROCHESTER, NY, 14623
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-04-10
|
Emphasis |
L: GUTREH, P: GUTREH
|
Case Closed |
2016-01-26
|
Related Activity
Type |
Inspection |
Activity Nr |
1055513 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2015-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2015-07-28 |
Final Order |
2015-12-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) On or about 04/17/15, during the renovation project at the new Maserati car dealership, located at 3865 West Henrietta Road, in Rochester, New York, a 10 foot, A-frame step ladder was in use in a closed position while accessing the eaves of the building. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2015-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-07-28 |
Final Order |
2015-12-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or step of a stepladder was used as a step: a) On or about 04/17/15, during the renovation project at the new Maserati car dealership, located at 3865 West Henrietta Road, in Rochester, New York, the top of a step ladder was in use as a step while accessing the building eaves. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260150 C01 I |
Issuance Date |
2015-07-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2015-07-28 |
Final Order |
2015-12-07 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: (a) On or about 04/17/15, during the renovation project at the new Maserati car dealership, located at 3865 West Henrietta Road, in Rochester, New York, fire fighting equipment such as a portable extinguisher was not available for use. PVC cement was in use, labeled "extremely flammable" and ignition sources (sparks) were present during the cutting of metal studs. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
339716110
|
0213600
|
2014-04-08
|
159 EAST MAIN STREET, ROCHESTER, NY, 14604
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-04-08
|
Emphasis |
L: GUTREH, P: GUTREH
|
Case Closed |
2014-12-18
|
Related Activity
Type |
Inspection |
Activity Nr |
972031 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
971750 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260405 J01 II |
Issuance Date |
2014-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
2100.0 |
Contest Date |
2014-06-04 |
Final Order |
2014-10-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: (a) On or about 04/08/14, at the Hilton Garden Inn, under renovation, located on 159 East Main Street, in Rochester, New York, a receptacle in use to power a portable heating unit and various power tools, was not anchored or secured to a supported structure. NO ABATEMENT CERITFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2014-05-28 |
Current Penalty |
0.0 |
Initial Penalty |
2800.0 |
Contest Date |
2014-06-04 |
Final Order |
2014-10-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. On or about 04/08/14, at the Hilton Garden Inn, under renovation, located on 159 East Main Street, in Rochester, New York, fall protection was not provided where floor holes were not covered or barricaded. NO ABATEMENT CERTIFICATION REQUIRED |
|
|
338028434
|
0213600
|
2012-12-19
|
133 BUELL STREET, CHEEKTOWAGA, NY, 14225
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-12-19
|
Emphasis |
N: CTARGET, P: CTARGET
|
Case Closed |
2013-07-05
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260405 B01 |
Issuance Date |
2013-02-01 |
Current Penalty |
0.0 |
Initial Penalty |
1200.0 |
Contest Date |
2013-02-11 |
Final Order |
2013-04-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: a) On or about 12/19/12, at the guest laundry room area of the site, Cheektowaga, NY. Fifteen unused openings in the panel box were covered up by duct tapes, not effectively closed. No Abatement Certification Required |
|
|