Search icon

DENOBLE CONSTRUCTION, LLC

Company Details

Name: DENOBLE CONSTRUCTION, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 15 Dec 2003 (21 years ago)
Entity Number: 2988789
ZIP code: 13066
County: Onondaga
Place of Formation: New York
Address: 7284 HIGHBRIDGE RD, FAYETTEVILLE, NY, United States, 13066

DOS Process Agent

Name Role Address
DENOBLE CONSTRUCTION, LLC DOS Process Agent 7284 HIGHBRIDGE RD, FAYETTEVILLE, NY, United States, 13066

History

Start date End date Type Value
2006-01-10 2023-12-13 Address 7284 HIGHBRIDGE RD, FAYETTEVILLE, NY, 13066, USA (Type of address: Service of Process)
2003-12-15 2006-01-10 Address 418 SWANSEA AVENUE, SYRACUSE, NY, 13206, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
231213024453 2023-12-13 BIENNIAL STATEMENT 2023-12-13
140414002336 2014-04-14 BIENNIAL STATEMENT 2013-12-01
111228002448 2011-12-28 BIENNIAL STATEMENT 2011-12-01
100108002176 2010-01-08 BIENNIAL STATEMENT 2009-12-01
071214002297 2007-12-14 BIENNIAL STATEMENT 2007-12-01
060110002066 2006-01-10 BIENNIAL STATEMENT 2005-12-01
031215000490 2003-12-15 ARTICLES OF ORGANIZATION 2003-12-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339542458 0215800 2014-01-10 6778 FLAMETREE DRIVE, FAYETTEVILLE, NY, 13066
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2014-01-10
Emphasis L: FALL, P: FALL
Case Closed 2014-03-31

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2014-01-27
Current Penalty 816.0
Initial Penalty 1360.0
Final Order 2014-02-06
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person: a) 6778 Flametree Drive residential Roof - On or about 10 January, 2014 - Employees were using a job built supported scaffold that was not designed by a qualified person.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2014-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-06
Nr Instances 2
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and/or walkway was not at least 18 inches (46 cm) wide: a) 6778 Flametree Drive residential Roof - On or about 10 January, 2014 - Employees were using a job built supported scaffold with the walkways were not at least 18 inches wide.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-01-27
Abatement Due Date 2014-02-06
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a job built supported scaffold where the walkways were not at least 18 inches wide, where the scaffold was not designed or built under the direction of a qualified person, and where the workers were not trained on the safe use of that scaffold.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-01-27
Current Penalty 816.0
Initial Penalty 1360.0
Final Order 2014-02-06
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladders length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigied support that will not deflect, and/or a grasping device was not provided to assist emmployees in mounting and dismounting the ladder. a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a ladder to access the upper landing surface of the scaffold that did not extend a minimum of 3 feet above the landing surface.
Citation ID 02001A
Citaton Type Other
Standard Cited 19260403 B02
Issuance Date 2014-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-06
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a relocatable power tap on the construction site that was not in accordance with the manufacturers and UL listing requirements.
Citation ID 02001B
Citaton Type Other
Standard Cited 19260405 G02 IV
Issuance Date 2014-01-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-02-06
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 6778 Flametree Drive residential Roof  On or about 10 January, 2014  Employees were using a circular saw that did not have strain relief provided to prevent pull from being directly transmitted to joints or terminal screws.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
1751129 Intrastate Non-Hazmat 2024-09-05 600 2023 1 2 Private(Property)
Legal Name DENOBLE CONSTRUCTION LLC
DBA Name -
Physical Address 7284 HIGHBRIDGE ROAD, FAYETTEVILLE, NY, 13066, US
Mailing Address 7284 HIGHBRIDGE ROAD, FAYETTEVILLE, NY, 13078, US
Phone (315) 632-4190
Fax (315) 632-4190
E-mail DENOBLECONSTRUCTION@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 29 Mar 2025

Sources: New York Secretary of State