Search icon

V & V CONSTRUCTION CORP.

Company Details

Name: V & V CONSTRUCTION CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 21 Jan 2004 (21 years ago)
Entity Number: 3002206
ZIP code: 11373
County: Queens
Place of Formation: New York
Address: 79-11 41ST AVE, APT A109, ELMHURST, NY, United States, 11373

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
JOSE AVAZQUEZ Chief Executive Officer 79-11 41ST AVE, APT A109, ELMHURST, NY, United States, 11373

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 79-11 41ST AVE, APT A109, ELMHURST, NY, United States, 11373

History

Start date End date Type Value
2004-01-21 2008-03-21 Address 79-11 41ST AVE. APT A 109, ELMHURST, NY, 11373, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
160307000067 2016-03-07 ANNULMENT OF DISSOLUTION 2016-03-07
DP-1943183 2011-01-26 DISSOLUTION BY PROCLAMATION 2011-01-26
100126000452 2010-01-26 ERRONEOUS ENTRY 2010-01-26
DP-1791507 2009-10-28 DISSOLUTION BY PROCLAMATION 2009-10-28
080321002801 2008-03-21 BIENNIAL STATEMENT 2008-01-01
040121000019 2004-01-21 CERTIFICATE OF INCORPORATION 2004-01-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340934926 0215000 2015-09-22 246-248 WEST 121ST STREET, NEW YORK, NY, 10027
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2015-09-22
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1017833
Safety Yes
Type Inspection
Activity Nr 1093521
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B01
Issuance Date 2015-10-19
Abatement Due Date 2015-10-29
Current Penalty 3500.0
Initial Penalty 4400.0
Contest Date 2016-08-31
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 246-248 West 121st Street, New York, NY. First Floor Leading to Basement Level. a) Employer did not protect employees, performing work near and around floor opening, from falling approximately 8 feet through the floor opening. On or about 09/22/2015. The V & V Contracting Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 1017833, citation number 1, item number 1 and was affirmed as a final order on 08/24/2015, with respect to a workplace located at 246-248 West 121st Street, New York, NY 10027.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19261052 C01
Issuance Date 2015-10-19
Current Penalty 3500.0
Initial Penalty 4400.0
Contest Date 2016-08-31
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge. Location: 246-248 West 121st Street New York, NY. a) Stairway leading from the basement level to the first level was not equipped with a handrail or stair rail. On or about 09/22/15. The V & V Contracting Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1052(c)(1), which was contained in OSHA inspection number 1017833, citation number 1, item number 4 and was affirmed as a final order on 08/24/2015, with respect to a workplace located at246-248 West 121st Street, New York, NY 10027.
340178334 0215000 2015-01-13 246-248 WEST 121 STREET, NEW YORK, NY, 10027
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2015-01-13
Case Closed 2017-04-11

Related Activity

Type Inspection
Activity Nr 1017757
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2015-07-02
Current Penalty 2020.0
Initial Penalty 2800.0
Contest Date 2016-01-28
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 6
Related Event Code (REC) Complaint
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Employees working from approximately 40 feet high were not provided with fall protection. Employees worked on the roof of a 4 story building.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2015-07-02
Current Penalty 2020.0
Initial Penalty 2800.0
Contest Date 2016-01-28
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 6
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Employees worked next to unguarded floor holes on the roof. Employees exposed to a fall of approximately 10 feet from the roof to the 3rd floor below.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 A03
Issuance Date 2015-07-02
Abatement Due Date 2015-07-15
Current Penalty 1680.0
Initial Penalty 2400.0
Contest Date 2016-01-28
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(a)(3): Variations in riser height or tread depth were not uniform in the stairway system. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was missing the riser/steps, employees were exposed to trip and fall hazards.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C01
Issuance Date 2015-07-02
Abatement Due Date 2015-07-15
Current Penalty 1680.0
Initial Penalty 2400.0
Contest Date 2016-01-28
Final Order 2017-02-06
Nr Instances 1
Nr Exposed 6
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was not equipped with a handrail or stairrail.
340087220 0215000 2014-11-18 27 GRANITE ST, BROOKLYN, NY, 11207
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2014-11-18
Case Closed 2014-11-21

Related Activity

Type Inspection
Activity Nr 960526
Safety Yes
340053628 0215000 2014-10-30 145 WEST 126TH ST, NEW YORK, NY, 10027
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2014-10-30
Emphasis L: FALL, L: GUTREH
Case Closed 2019-12-17

Related Activity

Type Complaint
Activity Nr 918808
Safety Yes
Type Inspection
Activity Nr 1005380
Safety Yes
Type Inspection
Activity Nr 1055552
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260304 I01
Issuance Date 2015-04-28
Current Penalty 1200.0
Initial Penalty 2800.0
Contest Date 2016-01-27
Final Order 2016-09-12
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood whcih completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut. Location; 145 west 126th Street, New York, NY 2nd Floor On or About October 30, 2014 a). Employees were using a portable 10" table saw to rip materials to repair/restore old entry doors and were exposed to amputation hazards because the saw blade above the rip table was not protected by the manufacturer provided guard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2015-04-28
Abatement Due Date 2015-05-08
Current Penalty 900.0
Initial Penalty 2000.0
Contest Date 2016-01-27
Final Order 2016-09-12
Nr Instances 10
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Location: 145 West 126th Street, New York, NY On or About October 30, 2014 a). Employees were engaged in a demolition project and were exposed to immanent danger conditions. Employees said they were not issued personal fall protection from the employer nor had they been trained to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:
Citation ID 01003
Citaton Type Serious
Standard Cited 19261052 C12
Issuance Date 2015-04-28
Current Penalty 1200.0
Initial Penalty 2800.0
Contest Date 2016-01-27
Final Order 2016-09-12
Nr Instances 2
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: Location 145 West 126th Street, New York, NY , first and second floor. a). Employees engaged in a GUT/REHAB project were not protected from falling to the floors below because the handrail systems around the existing stairwells had been demolished. Employees were utilizing these stairs to traverse throughout the project.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260404 F06
Issuance Date 2015-04-28
Current Penalty 2700.0
Initial Penalty 4000.0
Contest Date 2016-01-27
Final Order 2016-09-12
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous LOCATION: 145 126th Street, New York, NY 10035, second floor front. On or About October 30, 2014 a) Employees were utilizing flexible extension cords to energize portable DeWalt Brand slide saw and table saw. The saws were not protected by a continuous path to ground because the flexible cord was missing the ground pin. V&V CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.404(f)(6) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 960526, CITATION NUMBER 1-2, ISSUED ON 05/20/2014, NOTE: FINAL ORDER DATE 06/17/2014.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260501 B04 I
Issuance Date 2015-04-28
Current Penalty 4000.0
Initial Penalty 5600.0
Contest Date 2016-01-27
Final Order 2016-09-12
Nr Instances 3
Nr Exposed 10
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such hole. Location: 145 West 126th Street, New York, NY Roof level, Second Floor, 1st Floor. On or About October 30, 2014. A). Employees were engaged in the removal and demolition of roofing materials at the above location and were exposed to falls over 6 feet to the floor below because employer did not ensure each employee was protected by personal fall arrest systems, covers, or guardrail systems erected around such hole. V&V CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.501(b)(4)(I) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 960526, CITATION NUMBER 1-4, ISSUED ON 05/20/2014, NOTE: FINAL ORDER DATE 06/17/2014.
339605263 0215000 2014-02-25 27 GRANITE ST., BROOKLYN, NY, 11207
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2014-02-25
Emphasis L: FALL, L: GUTREH, P: FALL
Case Closed 2017-08-02

Related Activity

Type Inspection
Activity Nr 960514
Safety Yes
Type Inspection
Activity Nr 960453
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2014-05-20
Abatement Due Date 2014-06-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-06-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The saw and the connected extension cord were not provided with a ground fault circuit interrupter. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2014-05-20
Abatement Due Date 2014-06-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-06-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. Both the saw's power cord and the connected extension cord were missing ground pins. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260405 B02
Issuance Date 2014-05-20
Abatement Due Date 2014-06-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-06-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The temporary outlet was energized and the outlet box did not have a cover. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2014-05-20
Abatement Due Date 2014-06-02
Current Penalty 2000.0
Initial Penalty 2000.0
Final Order 2014-06-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) 3rd floor: Employees were framing on the 3rd floor, which the entire floor was removed during ongoing demolition operations and was not fully decked to cover all floor holes and openings. Employees were exposed falling approximately 10 feet through holes to the 2nd floor. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19.
307968743 0215000 2004-08-18 59 ST. MARKS PLACE, BROOKLYN, NY, 11217
Inspection Type Prog Related
Scope NoInspection
Safety/Health Safety
Close Conference 2004-08-18
Emphasis L: CONSTLOC
Case Closed 2004-08-19

Date of last update: 29 Mar 2025