340934926
|
0215000
|
2015-09-22
|
246-248 WEST 121ST STREET, NEW YORK, NY, 10027
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-09-22
|
Emphasis |
L: FALL, P: FALL
|
Related Activity
Type |
Inspection |
Activity Nr |
1017833 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1093521 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B01 |
Issuance Date |
2015-10-19 |
Abatement Due Date |
2015-10-29 |
Current Penalty |
3500.0 |
Initial Penalty |
4400.0 |
Contest Date |
2016-08-31 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 246-248 West 121st Street, New York, NY. First Floor Leading to Basement Level. a) Employer did not protect employees, performing work near and around floor opening, from falling approximately 8 feet through the floor opening. On or about 09/22/2015. The V & V Contracting Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(1), which was contained in OSHA inspection number 1017833, citation number 1, item number 1 and was affirmed as a final order on 08/24/2015, with respect to a workplace located at 246-248 West 121st Street, New York, NY 10027. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19261052 C01 |
Issuance Date |
2015-10-19 |
Current Penalty |
3500.0 |
Initial Penalty |
4400.0 |
Contest Date |
2016-08-31 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge. Location: 246-248 West 121st Street New York, NY. a) Stairway leading from the basement level to the first level was not equipped with a handrail or stair rail. On or about 09/22/15. The V & V Contracting Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1052(c)(1), which was contained in OSHA inspection number 1017833, citation number 1, item number 4 and was affirmed as a final order on 08/24/2015, with respect to a workplace located at246-248 West 121st Street, New York, NY 10027. |
|
|
340178334
|
0215000
|
2015-01-13
|
246-248 WEST 121 STREET, NEW YORK, NY, 10027
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-13
|
Case Closed |
2017-04-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1017757 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2015-07-02 |
Current Penalty |
2020.0 |
Initial Penalty |
2800.0 |
Contest Date |
2016-01-28 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Employees working from approximately 40 feet high were not provided with fall protection. Employees worked on the roof of a 4 story building. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2015-07-02 |
Current Penalty |
2020.0 |
Initial Penalty |
2800.0 |
Contest Date |
2016-01-28 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Employees worked next to unguarded floor holes on the roof. Employees exposed to a fall of approximately 10 feet from the roof to the 3rd floor below. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 A03 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-15 |
Current Penalty |
1680.0 |
Initial Penalty |
2400.0 |
Contest Date |
2016-01-28 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(a)(3): Variations in riser height or tread depth were not uniform in the stairway system. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was missing the riser/steps, employees were exposed to trip and fall hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 |
Issuance Date |
2015-07-02 |
Abatement Due Date |
2015-07-15 |
Current Penalty |
1680.0 |
Initial Penalty |
2400.0 |
Contest Date |
2016-01-28 |
Final Order |
2017-02-06 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge. Site: 246-248 West 121st Street New York, NY On or about 1/13/15 a) Stairway leading from the 1st level to the 3rd level was not equipped with a handrail or stairrail. |
|
|
340087220
|
0215000
|
2014-11-18
|
27 GRANITE ST, BROOKLYN, NY, 11207
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-11-18
|
Case Closed |
2014-11-21
|
Related Activity
Type |
Inspection |
Activity Nr |
960526 |
Safety |
Yes |
|
|
340053628
|
0215000
|
2014-10-30
|
145 WEST 126TH ST, NEW YORK, NY, 10027
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-10-30
|
Emphasis |
L: FALL, L: GUTREH
|
Case Closed |
2019-12-17
|
Related Activity
Type |
Complaint |
Activity Nr |
918808 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1005380 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1055552 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2015-04-28 |
Current Penalty |
1200.0 |
Initial Penalty |
2800.0 |
Contest Date |
2016-01-27 |
Final Order |
2016-09-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood whcih completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut. Location; 145 west 126th Street, New York, NY 2nd Floor On or About October 30, 2014 a). Employees were using a portable 10" table saw to rip materials to repair/restore old entry doors and were exposed to amputation hazards because the saw blade above the rip table was not protected by the manufacturer provided guard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2015-04-28 |
Abatement Due Date |
2015-05-08 |
Current Penalty |
900.0 |
Initial Penalty |
2000.0 |
Contest Date |
2016-01-27 |
Final Order |
2016-09-12 |
Nr Instances |
10 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: Location: 145 West 126th Street, New York, NY On or About October 30, 2014 a). Employees were engaged in a demolition project and were exposed to immanent danger conditions. Employees said they were not issued personal fall protection from the employer nor had they been trained to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 C12 |
Issuance Date |
2015-04-28 |
Current Penalty |
1200.0 |
Initial Penalty |
2800.0 |
Contest Date |
2016-01-27 |
Final Order |
2016-09-12 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: Location 145 West 126th Street, New York, NY , first and second floor. a). Employees engaged in a GUT/REHAB project were not protected from falling to the floors below because the handrail systems around the existing stairwells had been demolished. Employees were utilizing these stairs to traverse throughout the project. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260404 F06 |
Issuance Date |
2015-04-28 |
Current Penalty |
2700.0 |
Initial Penalty |
4000.0 |
Contest Date |
2016-01-27 |
Final Order |
2016-09-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous LOCATION: 145 126th Street, New York, NY 10035, second floor front. On or About October 30, 2014 a) Employees were utilizing flexible extension cords to energize portable DeWalt Brand slide saw and table saw. The saws were not protected by a continuous path to ground because the flexible cord was missing the ground pin. V&V CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.404(f)(6) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 960526, CITATION NUMBER 1-2, ISSUED ON 05/20/2014, NOTE: FINAL ORDER DATE 06/17/2014. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B04 I |
Issuance Date |
2015-04-28 |
Current Penalty |
4000.0 |
Initial Penalty |
5600.0 |
Contest Date |
2016-01-27 |
Final Order |
2016-09-12 |
Nr Instances |
3 |
Nr Exposed |
10 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such hole. Location: 145 West 126th Street, New York, NY Roof level, Second Floor, 1st Floor. On or About October 30, 2014. A). Employees were engaged in the removal and demolition of roofing materials at the above location and were exposed to falls over 6 feet to the floor below because employer did not ensure each employee was protected by personal fall arrest systems, covers, or guardrail systems erected around such hole. V&V CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD, ITS EQUIVALENT, OR ESSENTIALLY SIMILAR STANDARD, 29 CFR 1926.501(b)(4)(I) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 960526, CITATION NUMBER 1-4, ISSUED ON 05/20/2014, NOTE: FINAL ORDER DATE 06/17/2014. |
|
|
339605263
|
0215000
|
2014-02-25
|
27 GRANITE ST., BROOKLYN, NY, 11207
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-02-25
|
Emphasis |
L: FALL, L: GUTREH, P: FALL
|
Case Closed |
2017-08-02
|
Related Activity
Type |
Inspection |
Activity Nr |
960514 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
960453 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2014-05-20 |
Abatement Due Date |
2014-06-02 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The saw and the connected extension cord were not provided with a ground fault circuit interrupter. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2014-05-20 |
Abatement Due Date |
2014-06-02 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. Both the saw's power cord and the connected extension cord were missing ground pins. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260405 B02 |
Issuance Date |
2014-05-20 |
Abatement Due Date |
2014-06-02 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. a) 3rd floor: Employees used an electric powered circular saw to do framing work. The saw was connected to an extension cord, which was routed to a temporary outlet device installed on the 3rd floor. The temporary outlet was energized and the outlet box did not have a cover. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2014-05-20 |
Abatement Due Date |
2014-06-02 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Final Order |
2014-06-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) 3rd floor: Employees were framing on the 3rd floor, which the entire floor was removed during ongoing demolition operations and was not fully decked to cover all floor holes and openings. Employees were exposed falling approximately 10 feet through holes to the 2nd floor. On or about 02/25/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT CERTIFICATION OF ABATEMENT FOR THIS ITEM. FAILURE TO COMPLY MAY RESULT IN AN ADDITIONAL PENALTY OF $1,000 AS PER 29 CFR 1903.19. |
|
|
307968743
|
0215000
|
2004-08-18
|
59 ST. MARKS PLACE, BROOKLYN, NY, 11217
|
|
Inspection Type |
Prog Related
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2004-08-18
|
Emphasis |
L: CONSTLOC
|
Case Closed |
2004-08-19
|
|