Search icon

ALL STAR CONSTRUCTION INC.

Company Details

Name: ALL STAR CONSTRUCTION INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Jan 2004 (21 years ago)
Entity Number: 3005808
ZIP code: 10904
County: Orange
Place of Formation: New York
Principal Address: 29 IRWIN AVE, MIDDLETOWN, NY, United States, 10940
Address: 29 IRWIN AVENUE, MIDDLETOWN, NY, United States, 10904

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
CARLOS PEREZ Chief Executive Officer ALL STAR CONSTRUCTION INC, 29 IRWIN AVENUE, MIDDLETOWN, NY, United States, 10940

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 29 IRWIN AVENUE, MIDDLETOWN, NY, United States, 10904

Filings

Filing Number Date Filed Type Effective Date
060303002312 2006-03-03 BIENNIAL STATEMENT 2006-01-01
040128000358 2004-01-28 CERTIFICATE OF INCORPORATION 2004-01-28

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
336738786 0213100 2012-10-09 100 BROADWAY, MENANDS, NY, 12204
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-10-09
Emphasis L: FALL
Case Closed 2016-08-01

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B10
Issuance Date 2012-11-05
Abatement Due Date 2012-11-09
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: (a) Building Roof - on or about October 9, 2012 - no fall protection system was being used on the roof deck. An acceptable means of fall protection would be for the employer to use warning lines and monitors. Fall height was approximately 21 feet from the roof deck to the ground.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2012-11-05
Abatement Due Date 2012-11-09
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: (a) Building Roof - on or about October 9, 2012 - fall protection training was not provided by the employer for the employees that were performing roofing work. Fall height was approximately 21 feet from the roof deck to the ground.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2012-11-05
Current Penalty 1360.0
Initial Penalty 1360.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) Right Side of the Building - on or about October 9, 2012 - the extension ladder that was used as access to the roof deck did not extend the requisite three feet above the upper landing. Fall height was approximately 21 feet from the roof deck to the ground.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261053 B08
Issuance Date 2012-11-05
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(8): Ladders placed in a location where they could be displaced by workplace activities or traffic, such as in passageways, doorways, or driveways, were not secured to prevent accidental displacement, nor was a barricade used to keep the activities or traffic away from the ladder: (a) Right Side of the Building - on or about October 9, 2012 - the extension ladder that was used as access to the roof deck was not secured from movement. Fall height was approximately 21 feet from the roof deck to the ground.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2012-11-05
Abatement Due Date 2012-11-09
Current Penalty 1600.0
Initial Penalty 1600.0
Final Order 2012-12-21
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: (a) Jobsite - on or about October 9, 2012 - ladder training was not provided by the employer for the employees that erected and used an extension ladder on this building to gain access on the roof deck.