Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-09-07
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-03-29
|
Related Activity
Type |
Inspection |
Activity Nr |
1262020 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260451 B01 |
Issuance Date |
2018-01-18 |
Current Penalty |
2772.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) A. On or about 09/07/17, at site of 53-03 Douglaston Pkwy, Douglaston, NY Employees working on the fabricated frame scaffolds were exposed to the hazard of falling approximately 18 ft. to the ground. The working platforms were installed with only two or three scaffold planks. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 IV |
Issuance Date |
2018-01-18 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs g(1)(i) through g(1)(vi) of this section, each employee working on a scaffold more than 10 above a lower level was not protected from falling to that lower level by the use of guardrails or personal fall arrest systems: A. On or about 09/07/17, scaffolds at 53-03 Douglaston Parkway, Douglaston, NY Employees working on fabricated scaffolds approximately 18 ft. while applying stucco to face of the building were exposed to the hazard of falls. Guardrails or personal fall arrest systems were not provided. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
Inspection Type |
Prog Related
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-09-07
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2023-03-29
|
Related Activity
Type |
Inspection |
Activity Nr |
1262060 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-01-18 |
Abatement Due Date |
2018-02-13 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer had not developed, implemented, and maintained a written hazard communication program included in the requirements outlined in 29 CFR 1910.1200(e)(1)(I) and (e)(1)(II): (Construction Reference: 1926.59) (a) On or about September 9 2017, at 5303 Douglaston Parkway, Douglaston, NY 11361 The employer had not developed a written hazard communication program for employees using hazardous chemicals including, but not limited to SPEC MIX® Fiber Base Coat Stucco SU-05 containing silica and Portland cement, while employees applied stucco to the side of a single family, residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2018-01-18 |
Abatement Due Date |
2018-02-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in workplace: (Construction Reference: 1926.59) (a) On or about September 9 2017, at 5303 Douglaston Parkway, Douglaston, NY 11361 The employer did not maintain and provide to employees, copies of the required safety data sheets for each hazardous chemical including but not limited to SPEC MIX® Fiber Base Coat Stucco SU-05 containing silica and Portland cement, while employees applied stucco to the side of a single family, residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2018-01-18 |
Abatement Due Date |
2018-02-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): The Employer did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area: (Construction Reference: 1926.59) (a) On or about September 9 2017, at 5303 Douglaston Parkway, Douglaston, NY 11361 The employer did not provide hazardous communication information and training to employees who used hazardous chemicals including but not limited to SPEC MIX® Fiber Base Coat Stucco SU-05 containing silica and Portland cement, while employees applied stucco to the side of a single family, residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100134 K06 |
Issuance Date |
2018-01-18 |
Abatement Due Date |
2018-02-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k)(6): The employer did not provide basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134 in written or oral format, to employees who wear respirators when such use is not required by this section or by the employer. (Construction Reference: 1926.103) (a) On or about September 9 2017, at 5303 Douglaston Parkway, Douglaston, NY 11361 The employer did not provide information on Appendix D of 29 CFR 1910.134 to employees who voluntarily used N95 dust masks for protection from silica dust while using hazardous chemicals including but not limited to SPEC MIX® Fiber Base Coat Stucco SU-05 containing silica and Portland cement, while employees applied stucco to the side of a single family, residential home. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2019-02-11 |
Abatement Due Date |
2019-03-01 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Final Order |
2019-03-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: A.) On or about Friday, August 24, 2018 at 53-03 Douglaston Parkway, Douglaston, NY 11361 The employer failed to certify abatement required for Citation 1, Items 1 (a), (b), (c) and Citation 2, Item 1, which were issued on 01/18/2018. Abatement certification for these items was due on 02/13/2018. ABATEMENT CERTIFICATION IS REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
|