Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-05-22
|
Emphasis |
L: GUTREH, L: LOCALTARG
|
Case Closed |
2012-08-14
|
Related Activity
Type |
Inspection |
Activity Nr |
449774 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260150 C01 IV |
Issuance Date |
2012-07-06 |
Current Penalty |
900.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-08-01 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(c)(1)(iv): One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway. (a) On or about 05/22/12, at the former Tut's Villa restaurant, under renovation, located on 2200 Buffalo Road, in Rochester, New York, fire extilnguishers were not available on site during construction. NO ABATEMENT CERTIFIICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260300 A |
Issuance Date |
2012-07-06 |
Current Penalty |
900.0 |
Initial Penalty |
1200.0 |
Final Order |
2012-08-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.300(a): Condition of tools. All hand and power tools and similar equipment, whether furnished by the employer or the employee, shall be maintained in a safe condition. On or about 05/22/12, at the former Tuts Villa Restaurant, (under renovation) located on 2200 Buffalo Road, in Rochester, New York, a table saw (RIGID Model TS2400-1), was defective. The ground pin had been broken off the corded plug. NO ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260304 I01 |
Issuance Date |
2012-07-06 |
Current Penalty |
1275.0 |
Initial Penalty |
1700.0 |
Final Order |
2012-08-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose the portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely cause tooth breakage. the hood shall be so mounted as to insure that its operation will be positive, reliable, and in true alignment with the saw; and the mounting shall be adequate in strength to resist any reasonable side thrust or other force tending to throw it out of line. [58 FR 35175, June 30, 1993; 61 FR 9227, March 7, 1996] On or about 05/22/12, at the former Tut's Villa Restaurant, (under renovation) located on 2200 Buffalo Road, in Rochester, New York, a table saw (RIGID Model TS2400-1), had been used without a hood guard on the saw blade to guard against accidental contact with the blade. NO ABATEMENT CERTIFICATION REQUIRED |
|
|