341634681
|
0213100
|
2016-07-13
|
1 SIR BILLS CIRCLE, JOHNSTOWN, NY, 12095
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2016-07-13
|
Case Closed |
2017-01-16
|
Related Activity
Type |
Complaint |
Activity Nr |
1111564 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261414 F |
Issuance Date |
2016-08-05 |
Abatement Due Date |
2016-08-11 |
Current Penalty |
0.0 |
Initial Penalty |
2138.0 |
Contest Date |
2016-08-26 |
Final Order |
2017-01-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1414(f): Wire rope clips used in conjunction with wedge sockets was not attached to the unloaded dead end of the rope only: (a) Johnstown High School, Fulton, NY - On July 12, 2016 and at times prior, a P&H Lattice boom Crane was operated with a wedge socket on the end of the boom, that had a wire clip attached to the live end of the wire rope. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19261433 D03 |
Issuance Date |
2016-08-05 |
Abatement Due Date |
2016-08-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-08-31 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1433(d)(3): Hook and ball assemblies and load blocks were not marked with their rated capacity and weight: (a) Johnstown High School, Fulton, NY - On July 12, 2016 and at times prior, a P&H Lattice boom Crane was operated without the load block being legibly marked for rated capacity and weight. |
|
|
339128795
|
0213100
|
2013-06-18
|
N. LAKE RD., HAINES FALLS, NY, 12436
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-06-18
|
Emphasis |
L: HIGHWAY
|
Case Closed |
2015-02-17
|
Related Activity
Type |
Complaint |
Activity Nr |
823901 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
913834 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
914106 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19261417 D |
Issuance Date |
2013-10-18 |
Current Penalty |
0.0 |
Initial Penalty |
2200.0 |
Final Order |
2013-11-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1417(d): The operator must not engage in any practice or activity that diverts his/her attention while actually engaged in operating the equipment, such as the use of cellular phones (other than when used for signal communications). a) Jobsite, North Lake Rd. Haines Falls, NY- On or about 06/18/13 - Crane operator was observed asleep at the controls of a P&H 540TC 40 ton crane during pile driving operations. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19261412 D01 XII |
Issuance Date |
2013-10-18 |
Abatement Due Date |
2013-10-30 |
Current Penalty |
2400.0 |
Initial Penalty |
3200.0 |
Final Order |
2013-11-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1412(d)(1)(xii): The employer did not inspect the operator cab windows for significant cracks, breaks, or other deficiencies that would hamper the operator's view. a) Jobsite, North Lake Rd. Haines Falls, NY- On or about 06/18/13- Crane operators view was obstructed by significant cracks in the overhead window and right side window. Mohawk Valley Crane Service, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1926.550 (a)(12), which was contained in OSHA inspection 311971535, citation number 01, item number 001(b) and was affirmed as a final order on 04/17/2009, with respect to a workplace located at Clay Hill Rd. Bridge Ft. Ann, NY 12827. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19260150 A04 |
Issuance Date |
2013-10-18 |
Abatement Due Date |
2013-10-30 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-11-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.150(a)(4): Firefighting equipment was not periodically inspected: a) Jobsite, North Lake Rd. Haines Falls, NY- On or about 06/18/13- ABC fire extinguisher located in the operators cab of the P&H 540 TC crane had not been annually inspected since 10/2009. |
|
|
339123986
|
0213100
|
2013-06-18
|
KING FUELS, TROY, NY, 12180
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2013-06-18
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2013-06-19
|
|
311971535
|
0213100
|
2008-04-15
|
CLAY HILL RD. BRIDGE, FT. ANN, NY, 12827
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-04-15
|
Emphasis |
S: HWY STREET BRIDGE CONSTR, S: STRUCK-BY, S: FALL FROM HEIGHT, S: ELECTRICAL, S: COMMERCIAL CONSTR, S: AMPUTATIONS, L: FALL, L: BRIDGE
|
Case Closed |
2011-01-18
|
Related Activity
Type |
Complaint |
Activity Nr |
205326093 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260550 A05 |
Issuance Date |
2008-06-20 |
Abatement Due Date |
2009-04-22 |
Current Penalty |
750.0 |
Initial Penalty |
1500.0 |
Contest Date |
2008-07-01 |
Final Order |
2009-04-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260550 A12 |
Issuance Date |
2008-06-20 |
Abatement Due Date |
2009-04-27 |
Contest Date |
2008-07-01 |
Final Order |
2009-04-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260550 A14 I |
Issuance Date |
2008-06-20 |
Abatement Due Date |
2009-04-27 |
Current Penalty |
750.0 |
Initial Penalty |
1050.0 |
Contest Date |
2008-07-01 |
Final Order |
2009-04-17 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260550 A16 |
Issuance Date |
2008-06-20 |
Abatement Due Date |
2008-07-03 |
Current Penalty |
1500.0 |
Initial Penalty |
1500.0 |
Contest Date |
2008-07-01 |
Final Order |
2009-04-17 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
10 |
|
|
307532721
|
0213100
|
2004-04-12
|
KING FUELS, TROY, NY, 12180
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2004-04-13
|
Emphasis |
L: FALL
|
Case Closed |
2005-05-19
|
Related Activity
Type |
Referral |
Activity Nr |
200746261 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260020 B01 |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Current Penalty |
420.0 |
Initial Penalty |
600.0 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19260353 E02 |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260550 G04 IA |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Initial Penalty |
750.0 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01005 |
Citaton Type |
Other |
Standard Cited |
19260850 A |
Issuance Date |
2004-06-17 |
Abatement Due Date |
2004-06-25 |
Initial Penalty |
750.0 |
Contest Date |
2004-07-13 |
Final Order |
2005-01-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
|
106822315
|
0213100
|
1989-08-17
|
PROSPECT & CHURCH STREETS, AMSTERDAM, NY, 12010
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1989-08-17
|
Case Closed |
1990-03-27
|
Related Activity
Type |
Referral |
Activity Nr |
901355867 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260100 A |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-08-28 |
Current Penalty |
120.0 |
Initial Penalty |
400.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260550 A01 |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-08-28 |
Current Penalty |
280.0 |
Initial Penalty |
280.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
07 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260051 A04 |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-08-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19260059 E01 |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19260059 H |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-09-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19260550 A06 |
Issuance Date |
1989-08-25 |
Abatement Due Date |
1989-08-28 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
|
|