347621864
|
0213600
|
2024-07-16
|
183 EAST MAIN STREET, FREDONIA, NY, 14063
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-07-16
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2024-11-14
|
Related Activity
Type |
Complaint |
Activity Nr |
2184673 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2024-08-13 |
Abatement Due Date |
2024-09-05 |
Current Penalty |
2204.25 |
Initial Penalty |
2939.0 |
Final Order |
2024-09-05 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 07/16/2024 in the production area: where employees transfer sulfuric acid from drums to smaller containers for use in the production. There were no facilities for drenching and flushing of the eyes and body in the production area. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2024-08-13 |
Current Penalty |
1322.25 |
Initial Penalty |
1763.0 |
Final Order |
2024-09-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5):Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: a) On or about 07/16/2024 in the woodshop; where employees were exposed to the unguarded blades of a box fan provided for comfort ventilation and sitting on a table near the work area. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2024-08-13 |
Abatement Due Date |
2024-09-05 |
Current Penalty |
2204.25 |
Initial Penalty |
2939.0 |
Final Order |
2024-09-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1):Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about 07/16/2024 in the fabrication area; where the drive belts/pulleys for the finning machine were not guarded. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 |
Issuance Date |
2024-08-13 |
Abatement Due Date |
2024-09-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to the requirements specified in 29 CFR1910.219 (m) and (o). a) a) On or about 07/16/2024 in the fabrication area; where the drive belts/pulleys for the finning machine were not guarded. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100178 L06 |
Issuance Date |
2024-08-13 |
Abatement Due Date |
2024-09-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2024-09-05 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(6):The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): a) On or about 07/16/2024 throughout the production areas; where employees operate a Toyota Forklift Truck (Model 7F GCU25; serial number 68948). The employer did not certify that employees were trained to operate the forklift truck. ABATEMENT CERTIFICATION REQUIRED |
|
|
343136156
|
0213600
|
2018-04-27
|
183 E. MAIN STREET #113, FREDONIA, NY, 14063
|
|
Inspection Type |
Planned
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Close Conference |
2018-04-27
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2018-04-27
|
|
340188523
|
0213600
|
2015-01-14
|
183 EAST MAIN STREET, FREDONIA, NY, 14063
|
|
Inspection Type |
FollowUp
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2015-01-14
|
Case Closed |
2015-02-04
|
Related Activity
Type |
Inspection |
Activity Nr |
977170 |
Safety |
Yes |
|
|
339771701
|
0213600
|
2014-05-14
|
183 EAST MAIN STREET, FREDONIA, NY, 14063
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2014-05-14
|
Case Closed |
2017-09-08
|
Related Activity
Type |
Complaint |
Activity Nr |
889413 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the production area, the pulleys and belts on the Brass Annealer were not guarded to protect in going nip points. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100213 A09 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requires of 1910.219: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the belt(s) and pulleys on the joiner/planer were not guarded from accidental contact. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100213 B03 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the Delta table saw was not equipped with a drop out or similar device to prevent unexpected start up following power outages. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100213 J03 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(j)(3): Hand-fed jointer(s) with horizontal cutting head(s) did not have automatic guard(s) which automatically adjusted to cover the unused portion of the head and/or remained in contact with the material at all times: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the guard on the joiner/planer did not automatically adjust or return to cover the cutting head. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the production area, a 4"x4" box with pre-punched knockouts was hung from a flexible cable to create a pendent box. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100304 G05 |
Issuance Date |
2014-09-26 |
Abatement Due Date |
2014-10-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: a) On or about 5/14/14 at The Tube Fabrication Company located at 183 East Main Street, Fredonia, New York; in the carpenter shop, the power cord for the joiner/planer was missing the ground prong. ABATEMENT CERTIFICATION REQUIRED |
|
|
339075244
|
0213600
|
2013-05-20
|
183 EAST MAIN STREET, FREDONIA, NY, 14063
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2013-05-22
|
Case Closed |
2018-01-02
|
Related Activity
Type |
Complaint |
Activity Nr |
819285 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100106 E06 I |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-19 |
Current Penalty |
1200.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors: a) On or 05/20/2013 in the chemical storage area; where a acetone (a Class 1B flammable liquid) was dispensed from a 55 gallon drum which was not grounded. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002A |
Citaton Type |
Other |
Standard Cited |
19100213 H01 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-19 |
Current Penalty |
0.0 |
Initial Penalty |
2000.0 |
Final Order |
2013-07-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut: a) On or about 05/22/2013 in the production area; where the DELTA radial arm saw was not equipped with a guard for the lower portion of the blade. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002B |
Citaton Type |
Other |
Standard Cited |
19100213 H04 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-07-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator: a) On or about 05/22/2013 in the production area; where the DELTA radial arm saw did not automatically return to the starting position when released by the operator. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100303 B02 |
Issuance Date |
2013-06-26 |
Abatement Due Date |
2013-07-19 |
Current Penalty |
0.0 |
Initial Penalty |
1600.0 |
Final Order |
2013-07-22 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. a) On or about 05/22/2013 in the production area; where a metal duplex receptacle box (approved only for mounted in place applications per the National Electrical Code) was used at the end of a flexible cord and used as an extension cord. ABATEMENT CERTIFICATION REQUIRED |
|
|