Name: | SILVER STAR HOME IMPROVEMENTS INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 08 Jul 2004 (21 years ago) |
Entity Number: | 3075615 |
ZIP code: | 11103 |
County: | Queens |
Place of Formation: | New York |
Address: | 30-98 43RD STREET, LONG ISLAND CITY, NY, United States, 11103 |
Principal Address: | 30-98 43RD ST, LONG ISLAND CITY, NY, United States, 11103 |
Contact Details
Phone +1 718-358-6310
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 30-98 43RD STREET, LONG ISLAND CITY, NY, United States, 11103 |
Name | Role | Address |
---|---|---|
CHRIS A CHRISTOOROU | Chief Executive Officer | 3724 MARTHA BLVD, BETHPAGE, NY, United States, 11714 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1270903-DCA | Active | Business | 2009-10-19 | 2025-02-28 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
060912002468 | 2006-09-12 | BIENNIAL STATEMENT | 2006-07-01 |
040708000454 | 2004-07-08 | CERTIFICATE OF INCORPORATION | 2004-07-08 |
Start date | End date | Type | Satisafaction | Restitution | Result |
---|---|---|---|---|---|
2022-12-09 | 2023-01-04 | Quality of Work | Yes | 0.00 | Resolved and Consumer Satisfied |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3629403 | TRUSTFUNDHIC | INVOICED | 2023-04-13 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3629404 | RENEWAL | INVOICED | 2023-04-13 | 100 | Home Improvement Contractor License Renewal Fee |
3559778 | LICENSE REPL | CREDITED | 2022-11-29 | 15 | License Replacement Fee |
3274141 | RENEWAL | INVOICED | 2020-12-23 | 100 | Home Improvement Contractor License Renewal Fee |
3274140 | TRUSTFUNDHIC | INVOICED | 2020-12-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3263356 | TRUSTFUNDHIC | INVOICED | 2020-11-30 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3263357 | RENEWAL | INVOICED | 2020-11-30 | 100 | Home Improvement Contractor License Renewal Fee |
3019903 | RENEWAL | INVOICED | 2019-04-18 | 100 | Home Improvement Contractor License Renewal Fee |
3019902 | TRUSTFUNDHIC | INVOICED | 2019-04-18 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2974080 | RENEWAL | INVOICED | 2019-02-01 | 100 | Home Improvement Contractor License Renewal Fee |
Number | Adjudicates | Phase | Disposition | Date | Fine amount | Date fine paid | description |
---|---|---|---|---|---|---|---|
TWC-230426 | Office of Administrative Trials and Hearings | Issued | Early Settlement | 2024-10-28 | 1250 | No data | Each vehicle having a gross vehicle weight rating of twenty-six thousand pounds or more and a conventional cab configuration in which the engine is mounted in front of the operator must be equipped with a convex mirror positioned on the front of such vehicle. When such vehicle is being operated, such mirror shall be adjusted so as to enable the operator thereof to see all points on an imaginary horizontal line which is three feet above the road, is one foot directly forward from the midpoint of the front of such motor vehicle, and extends the full width of the front of such vehicle or combination of vehicles. |
TWC-7828 | Office of Administrative Trials and Hearings | Issued | Settled | 2012-01-04 | 3000 | No data | Removed collected or disposed of trade waste or without the proper Commission issued license or exemption from licensing requirements |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
334940988 | 0214700 | 2012-06-28 | 237 SMITH STREET, MERRICK, NY, 11566 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 494041 |
Safety | Yes |
Type | Complaint |
Activity Nr | 420850 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2012-08-07 |
Current Penalty | 1300.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-08-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite - An employee working directly under roof work, where employees were using tools, did not have head protection; on or about 06/28/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2012-08-07 |
Current Penalty | 1300.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-08-21 |
Nr Instances | 1 |
Nr Exposed | 5 |
Related Event Code (REC) | Complaint |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Worksite - Employees were working, at a height of approximately 28 feet above the ground, on an approximately 14-12 pitch residential roof without fall protection; on or about 06/28/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260951 C01 |
Issuance Date | 2012-08-07 |
Current Penalty | 1300.0 |
Initial Penalty | 2800.0 |
Final Order | 2012-08-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.951(c)(1): Portable conductive ladder(s) were used near energized lines or equipment: a) worksite - Employees were using a metal ladder to gain access to the roof that was approximately 3 inches away from the approximately 220 volts house service line, on or about 06/28/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2012-08-07 |
Current Penalty | 1100.0 |
Initial Penalty | 2000.0 |
Final Order | 2012-08-21 |
Nr Instances | 1 |
Nr Exposed | 8 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a)Worksite - Employees were using a ladder to gain access to a roof. The ladder was not secured and the side rails extended approximately 18 inches above the upper landing; on or about 06/28/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |