Search icon

SUNRISE REMODELING INC.

Company Details

Name: SUNRISE REMODELING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 23 Aug 2004 (21 years ago)
Entity Number: 3093576
ZIP code: 11792
County: Suffolk
Place of Formation: New York
Address: 49 S VIEW CT, 49 S View Ct, WADING RIVER, NY, United States, 11792
Principal Address: 49 S VIEW CT, WADING RIVER, NY, United States, 11792

Shares Details

Shares issued 1500

Share Par Value 1

Type PAR VALUE

Agent

Name Role Address
JAMES COOKE JR. Agent 58 PINELAWN AVE., SHIRLEY, NY, 11967

DOS Process Agent

Name Role Address
JAMES COOKE DOS Process Agent 49 S VIEW CT, 49 S View Ct, WADING RIVER, NY, United States, 11792

Chief Executive Officer

Name Role Address
JAMES COOKE Chief Executive Officer 49 S VIEW CT, WADING RIVER, NY, United States, 11792

History

Start date End date Type Value
2024-02-04 2024-02-04 Address 100 DURKEE LN, EAST PATCHOGUE, NY, 11772, USA (Type of address: Chief Executive Officer)
2024-02-04 2024-02-04 Address 49 S VIEW CT, WADING RIVER, NY, 11792, USA (Type of address: Chief Executive Officer)
2013-04-11 2024-02-04 Address JAMES COOKE, 100 DURKE LN, EAST PATCHOGUE, NY, 11772, USA (Type of address: Service of Process)
2013-04-11 2024-02-04 Address 100 DURKEE LN, EAST PATCHOGUE, NY, 11772, USA (Type of address: Chief Executive Officer)
2004-08-23 2024-02-04 Address 58 PINELAWN AVE., SHIRLEY, NY, 11967, USA (Type of address: Registered Agent)
2004-08-23 2024-02-04 Shares Share type: PAR VALUE, Number of shares: 1500, Par value: 1
2004-08-23 2013-04-11 Address 58 PINELAWN AVE., SHIRLEY, NY, 11967, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240204000064 2024-02-04 BIENNIAL STATEMENT 2024-02-04
130411002069 2013-04-11 BIENNIAL STATEMENT 2012-08-01
040823000564 2004-08-23 CERTIFICATE OF INCORPORATION 2004-08-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339623274 0214700 2014-03-10 2084 SMITH STREET, MERRICK, NY, 11566
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-03-10
Emphasis L: FALL, P: FALL
Case Closed 2019-03-15

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2014-07-29
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-08-26
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. (a) 2084 Smith Street, Merrick, NY (Worksite), residential home, west side - An employee was cutting and removing the existing roof sheathing along the western side of the second story roof. The employee was using a DeWalt circular saw, without any form of eye protection on, or about March 10, 2014. (b) Worksite, residential home, east side - An employee was installing and fastening new roof sheathing along the eastern side of the second story roof. The employee was using a Bostitch pneumatic nail gun, firing 28 degree wire weld framing nails, without any form of eye protection on, or about March 10, 2014. Note: Abatement for this violation was previously documented; therefore, the employer is not required to submit abatement certification or documentation for this violation in accordance with 29 CFR 1903.19.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-07-29
Current Penalty 1960.0
Initial Penalty 2800.0
Final Order 2014-08-26
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Worksite, residential home, west side - An employee was removing the existing shingles and roof sheathing along the western edge of the second story roof, which was a 4:12 pitched roof. The employee was working at heights ranging between 19.1' (19'-2") and 22.7' (22'-9") above the ground below, without fall protection on, or about March 10, 2014. (b) Worksite, residential home, east side - An employee was installing new sheathing and fascia along the eastern edge of the second story roof, which was a 4:12 pitched roof. The employee was working at a height of 21.9' (21'-11") above the ground below, without fall protection on, or about March 10, 2014. Note: Abatement for this violation was previously documented; therefore, the employer is not required to submit abatement certification for this violation in accordance with 29 CFR 1903.19.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2014-07-29
Abatement Due Date 2014-08-15
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-08-26
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: (a) Worksite, residential home, west side - An employee was removing the existing shingles and roof sheathing along the western edge of the low pitched, 4:12, second story roof. The employee was working at heights ranging between 19.1' (19'-2") and 22.7' (22'-9") above the ground below, without fall protection. The employees did not recognize the fall hazards; were unaware of the procedures to minimize them; and were not provided with fall protection training on, or about March 10, 2014. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this violation in accordance with 29 CFR 1903.19.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
3373007110 2020-04-11 0235 PPP 49 S VIEW CT, WADING RIVER, NY, 11792-1047
Loan Status Date 2021-08-24
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 28750
Loan Approval Amount (current) 28750
Undisbursed Amount 0
Franchise Name -
Lender Location ID 29805
Servicing Lender Name TD Bank, National Association
Servicing Lender Address 2035 Limestone Rd, WILMINGTON, DE, 19808-5529
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address WADING RIVER, SUFFOLK, NY, 11792-1047
Project Congressional District NY-01
Number of Employees 5
NAICS code 236118
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 29805
Originating Lender Name TD Bank, National Association
Originating Lender Address WILMINGTON, DE
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 29102.99
Forgiveness Paid Date 2021-07-07
7790128509 2021-03-06 0235 PPS 49 S View Ct, Wading River, NY, 11792-1047
Loan Status Date 2022-07-15
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 28160
Loan Approval Amount (current) 28160
Undisbursed Amount 0
Franchise Name -
Lender Location ID 29805
Servicing Lender Name TD Bank, National Association
Servicing Lender Address 2035 Limestone Rd, WILMINGTON, DE, 19808-5529
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Wading River, SUFFOLK, NY, 11792-1047
Project Congressional District NY-01
Number of Employees 3
NAICS code 236118
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 29805
Originating Lender Name TD Bank, National Association
Originating Lender Address WILMINGTON, DE
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 28522.17
Forgiveness Paid Date 2022-06-16

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2384600 Intrastate Non-Hazmat 2013-03-06 - - 1 1 Private(Property)
Legal Name SUNRISE REMODELING INC
DBA Name -
Physical Address 100 DURKEE LN, EAST PATCHOGUE, NY, 11772, US
Mailing Address 100 DURKEE LN, EAST PATCHOGUE, NY, 11772, US
Phone (631) 445-6434
Fax -
E-mail -

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 29 Mar 2025

Sources: New York Secretary of State