Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2019-08-07
|
Emphasis |
L: HHHT50, P: HHHT50
|
Case Closed |
2019-09-16
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2019-08-20 |
Abatement Due Date |
2019-09-12 |
Current Penalty |
1278.75 |
Initial Penalty |
1705.0 |
Final Order |
2019-09-09 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Assembly Area, on or about 8/7/19: Victor Lathe, the rotating chuck was not guarded. b) Assembly Area, on or about 8/7/19: Bridgeport Vertical Mill was not provided with a chuck and tool guard. c) Assembly Area, on or about 8/7/19: Horizontal Band Saw was not protected with a guard on the unused portion of the blade on the right and left side. d) Assembly Area, on or about 8/7/19: Belt Sander, the moving belt was not guarded. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2019-08-20 |
Abatement Due Date |
2019-09-12 |
Current Penalty |
1278.75 |
Initial Penalty |
1705.0 |
Final Order |
2019-09-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) Assembly Area, on or about 8/7/19: The Belt Sander was not provided with a guard over the in-running nip points of the belt and pulley drive. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100219 E01 I |
Issuance Date |
2019-08-20 |
Abatement Due Date |
2019-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a) Assembly Area, on or about 8/7/19: The Belt Sander was not provided with a guard over the in-running nip points of the belt and pulley drive. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100157 C01 |
Issuance Date |
2019-08-20 |
Abatement Due Date |
2019-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-09-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Assembly Area, on or about 8/7/19: A portable fire extinguisher was not mounted so that it was readily accessible. |
|
|