OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339993834 0213100 2014-10-08 112 MAIN ST., MOUNTAIN DALE, NY, 12763
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2014-10-08
Case Closed 2016-12-12

Related Activity

Type Referral
Activity Nr 913902
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2014-12-29
Current Penalty 1820.0
Initial Penalty 2800.0
Final Order 2015-01-28
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) Scaffold in Corner - On or about October 8, 2014, an employee was exposed to fall hazards of approximately 116 inches (9.66 feet) due to working on a scaffold without adequate planking due to there being a gap of approximately 22 inches.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2014-12-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-28
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) "Mead" Scaffold - On or about October 8, 2014, employees were exposed to fall hazards of approximately 10 feet 10 inches due to working on a scaffold without adequate fall protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260451 E07
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 780.0
Initial Penalty 1200.0
Final Order 2015-01-28
Nr Instances 2
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(7): Steps and rungs of ladder and stairway type access did not line up vertically with each other between rest platforms: a) "Mead" Scaffold - On or about October 8, 2014, employees were exposed to fall hazards due to accessing steps and rungs of a ladder that did not line up vertically on the integral prefabricated scaffold access. b) Scaffold in Corner - On or about October 8, 2014, an employee was exposed to fall hazards due to accessing steps and rungs of a ladder that did not line up vertically on the integral prefabricated scaffold access.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260452 W01
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-28
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(1): All brace connections were not secured: a) Scaffold in Corner - On or about October 8, 2014, all brace connections were not installed and secured on the scaffold. b) "Mead" Scaffold - On or about October 8, 2014, all brace connections were not installed and secured on the scaffold. c) Insulation Spraying Scaffold - On or about October 8, 2014, all brace connections were not installed and secured on the scaffold.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19260452 W02
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-28
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: a) Scaffold in Corner - On or about October 8, 2014, an employee was working on a scaffold without all of the wheels locked exposing the employee to approximately 116 inch (9.66 feet) fall hazards. b) "Mead" Scaffold - On or about October 8, 2014, employees were working on a scaffold without the any of the wheels locked on the scaffold exposing employees to approximately 10 feet 10 inch fall hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 1820.0
Initial Penalty 2800.0
Final Order 2015-01-28
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Scaffold in Corner - On or about October 8, 2014, an employee who performed work while on a scaffold was not trained by a person qualified in the subject matter to adequately recognize any hazards. b) "Mead" Scaffold - On or about October 8, 2014, an employee who performed work while on a scaffold was not trained by a person qualified in the subject matter to adequately recognize any hazards.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260454 B
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-28
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) Scaffold in Corner - On or about October 8, 2014, an employee involved in erecting and moving a scaffold was not trained by a competent person to adequately recognize any hazards with performing the work on the scaffold. b) "Mead" Scaffold - On or about October 8, 2014, an employee involved in the erecting and moving of a scaffold was not trained by a competent person to adequately recognize any hazards with performing the work on the scaffold.
Citation ID 02001
Citaton Type Other
Standard Cited 19260452 C03
Issuance Date 2014-12-29
Abatement Due Date 2015-01-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-01-28
Nr Instances 2
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(3): Frames and panels were not joined together vertically by coupling or stacking pins or equivalent means: a) Scaffold in Corner - On or about October 8, 2014, coupling or stacking pins were not used to join frames and panels together vertically. b) "Mead" Scaffold - On or about October 8, 2014, coupling or stacking pins were not used to join frames and panels together vertically.