347269938
|
0216000
|
2024-02-07
|
140 SAMSONDALE AVE., WEST HAVERSTRAW, NY, 10993
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-02-07
|
Emphasis |
N: FALL
|
Case Closed |
2024-08-20
|
Related Activity
Type |
Referral |
Activity Nr |
2129520 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1726948 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1727004 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260502 B01 |
Issuance Date |
2024-07-09 |
Abatement Due Date |
2024-08-02 |
Current Penalty |
0.0 |
Initial Penalty |
4610.0 |
Final Order |
2024-08-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level. On or about: February 7, 2024 Location: 140 Samsondale Ave., West Haverstraw, NY 10993. Eastern/left section of the air recirculation chamber. a) The top guardrail of the scaffold in use by a worker was measured between approximately 36-37 inches. Worker exposed to fall hazard due to inadequate fall protection. |
|
|
346658081
|
0214700
|
2023-04-26
|
204 MAPLE AVE, ROCKVILLE CENTRE, NY, 11570
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-26
|
Case Closed |
2023-08-04
|
Related Activity
Type |
Complaint |
Activity Nr |
2020416 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100253 B02 IV |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-06-14 |
Current Penalty |
2679.0 |
Initial Penalty |
2679.0 |
Final Order |
2023-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use. a) Worksite: 204 Maple Avenue, Rockville Centre, NY 11570 - Stored Compressed gas cylinders of Oxygen and Acetylene were not in use and missing valve caps, on or about 4/26/23. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100253 B04 III |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-06-14 |
Current Penalty |
2679.0 |
Initial Penalty |
2679.0 |
Final Order |
2023-07-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials, a minimum distance of 20 feet: a) Worksite: 204 Maple Avenue, Rockville Centre, NY 11570 - Compressed gas cylinders of Oxygen and Acetylene were stored next to one another and left on a cart hooked up to regulators; on or about 4/26/23. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
|