Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-08-16
|
Case Closed |
2013-08-13
|
Related Activity
Type |
Referral |
Activity Nr |
509395 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100147 C01 |
Issuance Date |
2013-01-14 |
Abatement Due Date |
2013-01-29 |
Current Penalty |
5670.0 |
Initial Penalty |
6300.0 |
Final Order |
2013-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1): Energy control program. The employer did not establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) 1P10370 Main elevator pit: On or about August 16, 2012 An employee was not protected from the hazard of being struck by the moving elevator weight. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100147 C04 |
Issuance Date |
2013-01-14 |
Abatement Due Date |
2013-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4): Energy control procedures. The employer did not use energy control procedures, on the machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment was not isolated from the energy source and rendered inoperative. a) 1P10370 Main elevator pit: On or about August 16, 2012 An employee was not protected from the hazard of being struck by the moving elevator weight. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19100147 C07 |
Issuance Date |
2013-01-14 |
Abatement Due Date |
2013-01-25 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-02-13 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7): Energy control program training. The employer did not establish energy control procedure employee training to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) 1P10370 Main elevator pit: On or about August 16, 2012 An employee was not protected from the hazard of being struck by the moving elevator weight. |
|
|