346534795
|
0213600
|
2023-02-28
|
175 ENSMINGER RD., TONAWANDA, NY, 14150
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-02-28
|
Emphasis |
N: AMPUTATE, P: AMPUTATE
|
Case Closed |
2023-09-20
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B03 IV |
Issuance Date |
2023-04-10 |
Abatement Due Date |
2023-05-02 |
Current Penalty |
4200.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(3)(iv): The employer did not ensure each employee was protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toe boards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. a) On or about 2/28/2023 by press # 52; employees were exposed to a fall hazard of approximately 10 feet when the top of the ladderway used to access the stacker mezzanine was open without any protection from falling into the opening at the top of the ladder. b) On or about 2/28/2023 by press # 52; employees were exposed to a fall hazard of approximately 10 feet when the top of the ladderway used to access the press panel mezzanine was open without any protection from falling into the opening at the top of the ladder. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 C06 I |
Issuance Date |
2023-04-10 |
Abatement Due Date |
2023-05-02 |
Current Penalty |
4200.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 02/28/2023 throughout the establishment, the employer did not observe authorized employees, at least annually, using lockout procedures on the machines or equipment such as, but not limited to Mechanical Power presses, on which employees are authorized to perform servicing and maintenance to ensure that the procedure and the requirements of this standard are being followed. ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2023-04-10 |
Abatement Due Date |
2023-05-02 |
Current Penalty |
2100.0 |
Initial Penalty |
4687.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: a) On or about 02/28/2023, in the maintenance shop, employees were exposed to being struck by flying debris when using the pedestal grinder for deburring with a work rest that was adjusted with an opening greater than 1/8". ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2023-04-10 |
Abatement Due Date |
2023-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: a) On or about 02/28/2023, in the maintenance shop, employees were exposed to being struck by flying debris when using the pedestal grinder for deburring with a tongue guard adjusted with an opening greater than 1/4". ABATEMENT CERTIFICATION REQUIRED |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100146 C02 |
Issuance Date |
2023-04-10 |
Abatement Due Date |
2023-05-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-05-05 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) On or about 02/28/2023, at Press #52, the loading pit, which employees enter to unjam/clean, did not have a posted sign or other effective means to inform employees of the danger posed by permit space(s). The space was incorrectly identified as a NON-PERMIT CONFINED SPACE. a) On or about 02/28/2023, at Press #52, under the press, which employees enter to do maintenance, did not have a posted sign or other effective means to inform employees of the danger posed by permit space(s). ABATEMENT DOCUMENTATION REQUIRED |
|
|
331907485
|
0213600
|
2012-02-01
|
175 ENSMINGER ROAD, TONAWANDA, NY, 14150
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-02-14
|
Emphasis |
N: SSTARG11
|
Case Closed |
2012-02-28
|
|
315095901
|
0213600
|
2010-12-21
|
175 ENSMINGER ROAD, TONAWANDA, NY, 14150
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-12-21
|
Case Closed |
2011-02-25
|
Related Activity
Type |
Complaint |
Activity Nr |
207403197 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 IID |
Issuance Date |
2011-02-02 |
Abatement Due Date |
2011-02-07 |
Current Penalty |
2475.0 |
Initial Penalty |
4950.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2011-02-02 |
Abatement Due Date |
2011-02-07 |
Current Penalty |
2475.0 |
Initial Penalty |
4950.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100147 E03 |
Issuance Date |
2011-02-02 |
Abatement Due Date |
2011-02-07 |
Current Penalty |
3465.0 |
Initial Penalty |
6930.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|
314669821
|
0213600
|
2010-07-20
|
175 ENSMINGER ROAD, TONAWANDA, NY, 14150
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2010-07-21
|
Emphasis |
N: AMPUTATE, S: AMPUTATIONS
|
Case Closed |
2010-09-30
|
Related Activity
Type |
Complaint |
Activity Nr |
207401795 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100147 D04 I |
Issuance Date |
2010-09-07 |
Abatement Due Date |
2010-10-10 |
Current Penalty |
2125.0 |
Initial Penalty |
2125.0 |
Nr Instances |
6 |
Nr Exposed |
6 |
Gravity |
03 |
|
|
312607179
|
0213600
|
2008-10-21
|
175 ENSMINGER ROAD, TONAWANDA, NY, 14150
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2008-10-27
|
Emphasis |
N: AMPUTATE
|
Case Closed |
2008-12-03
|
Related Activity
Type |
Complaint |
Activity Nr |
206234742 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2008-10-30 |
Abatement Due Date |
2008-12-02 |
Current Penalty |
1875.0 |
Initial Penalty |
1875.0 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 IIC |
Issuance Date |
2008-10-30 |
Abatement Due Date |
2008-12-02 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
03 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 IV |
Issuance Date |
2008-10-30 |
Abatement Due Date |
2008-12-02 |
Nr Instances |
1 |
Nr Exposed |
40 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100217 C03 IIIE |
Issuance Date |
2008-10-30 |
Abatement Due Date |
2008-11-17 |
Initial Penalty |
1875.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
03 |
|
|