Search icon

BAKEWISE BRANDS, INC.

Company Details

Name: BAKEWISE BRANDS, INC.
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Active
Date of registration: 08 Jul 2005 (20 years ago)
Entity Number: 3228147
ZIP code: 14625
County: Wayne
Place of Formation: Delaware
Principal Address: 150 Linden Oaks, Suite A, Rochester, NY, United States, 14625
Address: 150 linden oaks, suite a, ROCHESTER, NY, United States, 14625

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
BAKEWISE BRANDS INC 401(K) PROFIT SHARING PLAN & TRUST 2011 203092680 2012-10-12 BAKEWISE BRANDS INC 166
File View Page
Three-digit plan number (PN) 001
Effective date of plan 2005-01-01
Business code 541990
Sponsor’s telephone number 3159869999
Plan sponsor’s mailing address 1688 N WAYNEPORT ROAD, MACEDON, NY, 14502
Plan sponsor’s address 1688 N WAYNEPORT ROAD, MACEDON, NY, 14502

Plan administrator’s name and address

Administrator’s EIN 203092680
Plan administrator’s name BAKEWISE BRANDS INC
Plan administrator’s address 1688 N WAYNEPORT ROAD, MACEDON, NY, 14502
Administrator’s telephone number 3159869999

Number of participants as of the end of the plan year

Active participants 144
Retired or separated participants receiving benefits 0
Other retired or separated participants entitled to future benefits 90
Deceased participants whose beneficiaries are receiving or are entitled to receive benefits 0
Number of participants with account balances as of the end of the plan year 157
Number of participants that terminated employment during the plan year with accrued benefits that were less than 100% vested 16

Signature of

Role Plan administrator
Date 2012-10-12
Name of individual signing KEITH BLEIER
Valid signature Filed with authorized/valid electronic signature

DOS Process Agent

Name Role Address
the corporation DOS Process Agent 150 linden oaks, suite a, ROCHESTER, NY, United States, 14625

Agent

Name Role
REGISTERED AGENT REVOKED Agent

Chief Executive Officer

Name Role Address
KEITH P BLEIER Chief Executive Officer 1688 N WAYNEPORT RD, MACEDON, NY, United States, 14502

History

Start date End date Type Value
2024-11-21 2024-11-21 Address 1688 N WAYNEPORT RD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2023-07-06 2024-11-21 Address 1218 CENTRAL AVENUE, STE 100, ALBANY, NY, 12205, USA (Type of address: Service of Process)
2023-07-06 2023-07-06 Address 1688 N WAYNEPORT RD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2023-07-06 2024-11-21 Address 1688 N WAYNEPORT RD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2013-07-11 2023-07-06 Address 1688 N WAYNEPORT RD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2011-05-02 2023-07-06 Address 1218 CENTRAL AVENUE, STE 100, ALBANY, NY, 12205, USA (Type of address: Service of Process)
2009-07-27 2013-07-11 Address 1688 N WAYNEPORT RD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2007-08-29 2009-07-27 Address 1688 NORTH WAYNEPORT ROAD, MACEDON, NY, 14502, USA (Type of address: Chief Executive Officer)
2005-07-25 2011-05-02 Name FLEISCHER'S BAGELS, INC.
2005-07-08 2011-05-02 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
241121002713 2024-11-20 CERTIFICATE OF CHANGE BY ENTITY 2024-11-20
230706004682 2023-07-06 BIENNIAL STATEMENT 2023-07-01
220329003546 2022-03-29 BIENNIAL STATEMENT 2021-07-01
190702060201 2019-07-02 BIENNIAL STATEMENT 2019-07-01
170726006122 2017-07-26 BIENNIAL STATEMENT 2017-07-01
150706006373 2015-07-06 BIENNIAL STATEMENT 2015-07-01
130711006137 2013-07-11 BIENNIAL STATEMENT 2013-07-01
110728002544 2011-07-28 BIENNIAL STATEMENT 2011-07-01
110502000057 2011-05-02 CERTIFICATE OF AMENDMENT 2011-05-02
090727002658 2009-07-27 BIENNIAL STATEMENT 2009-07-01

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2024-01-16 BAKEWISE BRANDS 1688 N WAYNEPORT RD, MACEDON, Wayne, NY, 14502 A Food Inspection Department of Agriculture and Markets No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346551559 0215800 2023-03-08 1688 N. WAYNEPORT ROAD, MACEDON, NY, 14502
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2023-03-08
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2023-05-31
343328191 0215800 2018-07-25 1688 N WAYNEPORT ROAD, MACEDON, NY, 14502
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2018-07-25
Case Closed 2018-07-26

Related Activity

Type Inspection
Activity Nr 1238444
Safety Yes
342384443 0215800 2017-05-24 1688 WAYNEPORT ROAD, MACEDON, NY, 14502
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-10-16
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2018-08-10

Related Activity

Type Complaint
Activity Nr 1215635
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2017-10-18
Current Penalty 8556.0
Initial Penalty 11408.0
Final Order 2017-11-13
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Divider #1, on or about 5/1/17: Neither lockout procedures in accordance with 29 CFR 1910.147(c)(4)(i) nor other effective alternative measures pursuant to 29 CFR 1910.147(a)(2)(ii) were utilized before the operator attempted to remove dough from the divider hopper. The operator sustained a right index finger tendon laceration when the knife came down on his hand.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2017-10-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-11-13
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a) Divider Area, on or about 5/1/17: Point of operation guarding was not provided to prevent the employees from reaching inside of the Divider Machine hoppers to remove dough. On 5/1/17 a machine operator reached into the hopper of Divider #1 and sustained a right index finger tendon laceration when the knife came down on his hand. b) Divider Area, on or about 5/1/17: Point of operation guarding was not provided to prevent the employees from reaching inside of the Divider Machine hoppers to remove dough. On 5/1/17 a machine operator reached into the hopper of Divider #2 and removed a ball of dough. The operator did not turn the machine off and was thereby exposed to the point of operation.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 D02
Issuance Date 2017-10-18
Current Penalty 8556.0
Initial Penalty 11408.0
Final Order 2017-11-13
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Forming Lines, on or about 5/24/17: An employee was picking up dough from under the forming lines and did not shut down the equipment first. Employee was exposed to in-running nip points of the belts and rollers.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100157 G02
Issuance Date 2017-10-18
Abatement Due Date 2017-11-02
Current Penalty 3666.75
Initial Penalty 4889.0
Final Order 2017-11-13
Nr Instances 1
Nr Exposed 13
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Bakewise Brands, Inc., on or about 7/25/17: Employees have not received fire extinguisher training on an annual basis. The last training session was provided to employees in 2014. *ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b).
Citation ID 01004
Citaton Type Serious
Standard Cited 19100219 C04 I
Issuance Date 2017-10-18
Abatement Due Date 2017-11-02
Current Penalty 7333.5
Initial Penalty 9778.0
Final Order 2017-11-13
Nr Instances 3
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: a) Oven Room, on or about 5/24/17: (3) Three unguarded shaft ends, each 1-1/4 inches in diameter, projected 2 to 3-1/2 inches.
Citation ID 02001
Citaton Type Other
Standard Cited 19040004 A
Issuance Date 2017-10-18
Current Penalty 0.0
Initial Penalty 1630.0
Final Order 2017-11-13
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. a) Bakewise Brands, Inc., on or about 5/24/17: The employer did not record a severe finger laceration which occurred on 5/1/17 that resulted in lost workdays on the OSHA Form 300 for calendar year 2017.
333989226 0215800 2012-04-23 1688 N. WAYNEPORT ROAD, MACEDON, NY, 14502
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2012-05-16
Emphasis N: AMPUTATE
Case Closed 2013-02-21

Related Activity

Type Referral
Activity Nr 320740
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100024 H
Issuance Date 2012-05-23
Abatement Due Date 2012-06-12
Current Penalty 1530.0
Initial Penalty 2550.0
Final Order 2012-07-10
Nr Instances 2
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: a) Mixing Area, on or about 4/24/12: Two (2) stair units each having 5 risers, were not provided with a standard railing along the open sides.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2012-05-23
Abatement Due Date 2012-05-29
Current Penalty 4200.0
Initial Penalty 7000.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) Bakewise Brands, Inc., on or about 4/23/12: Authorized employee performing servicing and/or maintenance activity on Reciprocator #2 was not trained to recognize the hazardous energy sources present and the methods and means necessary for energy isolation.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100147 D02
Issuance Date 2012-05-23
Abatement Due Date 2012-06-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Make-up Area, on or about 4/30/12: Employee did not shut down and lockout Reciprocator #2 prior to wiping excess oil from the chain rail. The employee's hand was pulled into the moving chain and sprocket resulting in an amputation injury.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2012-05-23
Abatement Due Date 2012-06-29
Current Penalty 2550.0
Initial Penalty 4250.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Throughout the facility, on or about 4/23/12: Lockout devices were not affixed to each energy isolation device during servicing and/or maintenance activites such as but not limited to, sanitizing equipment.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100147 F03 I
Issuance Date 2012-05-23
Abatement Due Date 2012-06-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 19
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(f)(3)(i): A procedure was not utilized to afford the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device when servicing and/or maintenance was performed by a crew, craft, a) Throughout the facility, on or about 4/23/2012: Group lockout procedures were not utilized where maintenance and sanitation crews were performing servicing and/or maintenance activities.
Citation ID 01004
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2012-05-23
Abatement Due Date 2012-06-29
Current Penalty 2040.0
Initial Penalty 3400.0
Final Order 2012-07-10
Nr Instances 3
Nr Exposed 9
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance, on or about 4/24/12: Rockwell drill press was not provided with a chuck guard. b) Maintenance, on or about 4/24/12: Bridgeport milling machine was not provided with a chuck guard. c) Forming Area, on or about 4/24/12: Former conveyor was not adequately guarded at the in-running point of the belt and roller.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2012-05-24
Abatement Due Date 2012-06-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2012-07-10
Nr Instances 1
Nr Exposed 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop and maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met; specifically: 1) Labeling and other forms of warning; 2) MSDS requirements for the hazardous materials known to be present at the jobsite; 3) Employee training and information. The written program must also include: (a) A list of all the chemicals used at the jobsite. (b) Methods to inform employees of hazards associated with non-routine tasks. (c) Methods the employer will use to inform any contractors employees of workplace hazards. a) Bakewise Brands, Inc., on or about 4/24/12: A written hazard communication program was not developed and maintained at the worksite for the employees who work with hazardous materials including but not limited to: FS Bakery Pan Cleaner, FS RTU-D2 Sanitizer and FS Amine A Sanitizer.

Date of last update: 11 Mar 2025

Sources: New York Secretary of State