OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343842241 0214700 2019-03-11 669 SUNRISE HWY, WEST BABYLON, NY, 11704
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2019-03-11
Emphasis L: FALL
Case Closed 2023-04-04

Related Activity

Type Referral
Activity Nr 1434667
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2019-05-13
Abatement Due Date 2019-05-23
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-07-26
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii). a) Worksite, 669 Sunrise Hwy, West Babylon, NY 11704 - Employees were performing stucco duties on the second tier of the fabricated frame scaffold approximately 13ft. above the ground. The second tier had only two planks installed, on or about 03/11/2019. b) Worksite, 669 Sunrise Hwy, West Babylon, NY 11704 - An employee was performing stucco duties on the first tier of the fabricated frame scaffold approximately 6ft. above the ground. The first tier hand only two planks installed, on or about 03/11/2019. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2019-05-13
Abatement Due Date 2019-05-23
Current Penalty 2842.0
Initial Penalty 2842.0
Final Order 2019-07-26
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite, 669 Sunrise Hwy, West Babylon, NY - Employees were performing stucco work on the first and second level of the fabricated frame scaffold approximately 13ft. above the ground below. The employees were not provided with access to the working levels of the fabricated frame scaffold, on or about 03/11/2019. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2019-05-13
Abatement Due Date 2019-05-23
Current Penalty 3978.0
Initial Penalty 3978.0
Final Order 2019-07-26
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Imminent Danger
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, 669 Sunrise Hwy, West Babylon, NY 11704 - Employees were performing stucco work on the second level of the fabricated frame scaffold approximately 13ft. above the ground without fall protection, on or about 03/11/2019. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.