Search icon

CELA CONTRACTING CORP.

Company Details

Name: CELA CONTRACTING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 16 Aug 2005 (20 years ago)
Date of dissolution: 27 Jul 2016
Entity Number: 3244141
ZIP code: 11103
County: Queens
Place of Formation: New York
Address: 25-63 STEINWAY ST, ASTORIA, NY, United States, 11103

Contact Details

Phone +1 718-626-8846

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 25-63 STEINWAY ST, ASTORIA, NY, United States, 11103

Chief Executive Officer

Name Role Address
BESNIK CELA Chief Executive Officer 25-63 STEINWAY ST, ASTORIA, NY, United States, 11103

Licenses

Number Status Type Date End date
2011947-DCA Inactive Business 2014-08-12 2015-02-28
1223431-DCA Inactive Business 2006-04-11 2013-06-30

History

Start date End date Type Value
2007-11-06 2009-12-02 Address 25-63 STEINWAY ST, ASTORIA, NY, 11103, USA (Type of address: Principal Executive Office)
2005-08-16 2009-12-02 Address 25-63 STEINWAY STREET, ASTORIA, NY, 11103, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
160727000376 2016-07-27 CERTIFICATE OF DISSOLUTION 2016-07-27
091202002786 2009-12-02 BIENNIAL STATEMENT 2009-08-01
071106002869 2007-11-06 BIENNIAL STATEMENT 2007-08-01
050816000399 2005-08-16 CERTIFICATE OF INCORPORATION 2005-08-16

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2014-03-14 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: Post-Audit Department of Transportation S/W REPAIRED
2013-09-06 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: Post-Audit Department of Transportation s/w passes inspection
2013-07-20 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: CAR Re-Inspect Department of Transportation Install expansion joint separate property lines and seal all joints on sidewalk(1 nov issued already as per john closed car)
2013-05-19 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: CAR Re-Inspect Department of Transportation I observed the above respondent failed to seal expansion joints
2013-03-15 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: Post-Audit Department of Transportation No data
2013-03-05 No data 79 STREET, FROM STREET 21 AVENUE TO STREET DITMARS BOULEVARD No data Street Construction Inspections: Complaint Department of Transportation No data
2013-01-15 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: Post-Audit Department of Transportation Install expansion joint separate property lines and seal all joints on sidewalk.
2012-09-25 No data 79 STREET, FROM STREET 21 AVENUE TO STREET DITMARS BOULEVARD No data Street Construction Inspections: Complaint Department of Transportation A/T/P/O I observed the respondent placed a construction container on street with no permit.
2012-08-26 No data 9 AVENUE, FROM STREET WEST 50 STREET TO STREET WEST 51 STREET No data Street Construction Inspections: Post-Audit Department of Transportation No data
2012-08-24 No data EAST 9 STREET, FROM STREET 1 AVENUE TO STREET AVENUE A No data Street Construction Inspections: Active Department of Transportation No data

Fine And Fees

Fee Sequence Id Fee type Status Date Amount Description
1758196 TRUSTFUNDHIC INVOICED 2014-08-12 200 Home Improvement Contractor Trust Fund Enrollment Fee
1758195 LICENSE INVOICED 2014-08-12 50 Home Improvement Contractor License Fee
1758198 FINGERPRINT CREDITED 2014-08-12 75 Fingerprint Fee
176898 LL VIO INVOICED 2012-01-13 250 LL - License Violation
748800 TRUSTFUNDHIC INVOICED 2011-06-17 200 Home Improvement Contractor Trust Fund Enrollment Fee
802214 RENEWAL INVOICED 2011-06-17 100 Home Improvement Contractor License Renewal Fee
748801 TRUSTFUNDHIC INVOICED 2009-05-27 200 Home Improvement Contractor Trust Fund Enrollment Fee
802215 RENEWAL INVOICED 2009-05-27 100 Home Improvement Contractor License Renewal Fee
748802 TRUSTFUNDHIC INVOICED 2007-05-03 200 Home Improvement Contractor Trust Fund Enrollment Fee
802216 RENEWAL INVOICED 2007-05-03 100 Home Improvement Contractor License Renewal Fee

Issued Charges

Date Outcome Charge Charge count Counts sellted Counts guilty Counts not guilty
2014-06-16 Settlement (Pre-Hearing) NO/IMPROPER NOTICE OF CANCELLATION 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) NO OR IMPROPER LIEN INFORMATION 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) ENGAGED in unfair or deceptive or unconscionable trade practice in the sale, lease, rental or loan or offering of any consumer goods or services, or in the collection of consumer debts. 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) NO OR IMPROPER DATES OF COMPLETION 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) CONTRACTOR DETAIL NOT IN CONTRACT 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) FITNESS 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) IMPROPER TYPEFACE OR SIZE 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) NO OR IMPROPER BOND INFORMATION 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) PERMIT NOT SECURED 1 1 No data No data
2014-06-16 Settlement (Pre-Hearing) NO OR IMPROPER PERMIT CLAUSE 1 1 No data No data

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
334274131 0214700 2012-05-04 26 S OCEAN, PATCHOGUE, NY, 11772
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2012-05-04
Emphasis L: FALL, N: CTARGET
Case Closed 2014-08-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2012-07-24
Current Penalty 750.0
Initial Penalty 2800.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.451(f)(6) Scaffold was erected and used such that it or any conductive material handled on it might come closer to exposed and energized power lines. Worksite, West Employees were working on a scaffold constructed within approximately 1 foot from energized power lines. Workers and materials were in close proximity to energized power lines on, or about, 05/04/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F07
Issuance Date 2012-07-24
Current Penalty 750.0
Initial Penalty 2800.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.451(f)(7) Scaffolds were not erected under the supervision and direction of a competent person qualified in scaffold erection, an activity, which should only be performed by experienced and trained employees selected for such work by the competent person. Worksite, West - Employees were working on a scaffold set up on a 9 foot roof. The scaffold was constructed by workers without direction from a competent person on, or about, 05/04/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01
Issuance Date 2012-07-24
Current Penalty 500.0
Initial Penalty 2800.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.451(g)(1) Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Worksite, West - Employees were working on a scaffold at the heights of approximately 16 feet without being protected by personal falls arrest systems, guardrails or safety nets on, or about, 05/04/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2012-07-24
Current Penalty 500.0
Initial Penalty 2800.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 1926.452(c)(2) Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. Worksite, West  Employees were conducting work activity on a scaffold constructed without complete bracing. The scaffold did not have bracing on the inner most side on, or about, 05/04/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2012-07-24
Abatement Due Date 2012-07-31
Current Penalty 500.0
Initial Penalty 1200.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 1926.454(a) The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Worksite, West - Employees were conducting work activity on a scaffold constructed without complete bracing and was set atop a 9 foot roof approximately 1 foot from live power lines on, or about, 05/04/12. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01006
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2012-07-24
Current Penalty 500.0
Initial Penalty 2000.0
Contest Date 2013-01-04
Final Order 2013-03-15
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1) Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Worksite, West - Employees were applying stucco and accessing a scaffold from a roof approximately 9 feet in height. Employees were not protected from falling, by guardrail systems, safety net systems or personal fall arrest systems on, or about, 05/04/12. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.