Search icon

J.P. SPANO BUILDING CORP.

Company Details

Name: J.P. SPANO BUILDING CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 17 Aug 2005 (20 years ago)
Entity Number: 3244939
ZIP code: 11978
County: Suffolk
Place of Formation: New York
Address: 48 FRANKLIN AVE, WESTHAMPTON BEACH, NY, United States, 11978

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 48 FRANKLIN AVE, WESTHAMPTON BEACH, NY, United States, 11978

Chief Executive Officer

Name Role Address
JOSEPH P SPANO Chief Executive Officer 48 FRANKLIN AVE, WESTHAMPTON BEACH, NY, United States, 11978

History

Start date End date Type Value
2007-10-11 2009-09-17 Address 48 FRANKVIEW AVE, WESTHAMPTON BEACH, NY, 11978, USA (Type of address: Chief Executive Officer)
2007-10-11 2009-09-17 Address 48 FRANKVIEW AVE, WESTHAMPTON BEACH, NY, 11978, USA (Type of address: Principal Executive Office)
2007-10-11 2009-09-17 Address 48 FRANKVIEW AVE, WESTHAMPTON BEACH, NY, 11978, USA (Type of address: Service of Process)
2005-08-17 2007-10-11 Address 48 FRANKLIN AVE, WESTHAMPTON BEACH, NY, 11978, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
131029002183 2013-10-29 BIENNIAL STATEMENT 2013-08-01
110829002538 2011-08-29 BIENNIAL STATEMENT 2011-08-01
090917002761 2009-09-17 BIENNIAL STATEMENT 2009-08-01
071011002738 2007-10-11 BIENNIAL STATEMENT 2007-08-01
050817000783 2005-08-17 CERTIFICATE OF INCORPORATION 2005-08-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342155330 0214700 2017-03-06 47 OLD MAIN RD., QUOGUE, NY, 11959
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2017-03-06
Emphasis L: FALL, P: FALL
Case Closed 2017-10-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2017-08-01
Abatement Due Date 2017-08-09
Current Penalty 2000.0
Initial Penalty 2716.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. a) Worksite, 47 Old Main Rd, Quogue, NY - Employees were using pneumatic nail guns on cedar wood shingles without eye protection; on or about 3/6/17. Note: The employer is required to provide abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2017-08-01
Abatement Due Date 2017-08-07
Current Penalty 2000.0
Initial Penalty 1630.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 47 Old Main Rd, Quogue, NY - Employees were working under overhead siding work without head protection; on or about 3/6/17. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260300 B04
Issuance Date 2017-08-01
Abatement Due Date 2017-08-09
Current Penalty 2000.0
Initial Penalty 3803.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.300(b)(4): "Point of operation guarding." a) Worksite, 47 Old Main Rd., Quogue: Guard was missing in DeWalt 745 Portable Saw (serial #201114 - CT100909) used by employees to cut cedar wood shingles; on or about 3/6/17. Note: In addition to abatement certification, the employee is required to submit abatement documentation for this violation in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-08-01
Abatement Due Date 2017-08-07
Current Penalty 2000.0
Initial Penalty 2716.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 47 Old Main Rd, Quogue, NY: Employees working on porch roof approximately 12ft. above ground did not have fall protection; on or about 3/6/17. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260503 A01
Issuance Date 2017-08-01
Abatement Due Date 2017-08-18
Current Penalty 2000.0
Initial Penalty 2716.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Worksite, 47 Old Main Rd., Quogue, NY: The employees were not trained to recognize the hazards associated with falling while working on the porch roof of a residential home approximately 12 feet above the ground below; on or about 3/6/17. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01006A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-08-01
Current Penalty 1400.0
Initial Penalty 2716.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite, 47 Old Main Rd, Quogue, NY : Employees were using a ladder to access a roof approximately 12ft. above the ground below. The portable ladder was not extended above the surface landing and was not securely tied to the building; on or about 3/6/17. Note: Because abatement of this violation is already documented in the case file, the employer need not to submit certification or documentation of abatement of this violation as normally required by 29 CFR 1903.19.
Citation ID 01006B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2017-08-01
Abatement Due Date 2017-08-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) Worksite, 47 Old Main Rd., Quogue, NY: Employees using metal ladder to access the porch roof of a residential home were not provided with ladder training; on or about 3/6/17. Note: The employer is required to provide abatement certification for this item in accordance with 29 CFR 1903.19.