Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-01-08
|
Emphasis |
L: LOCALTARG, P: LOCALTARG
|
Case Closed |
2021-09-26
|
Related Activity
Type |
Inspection |
Activity Nr |
1454376 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260404 F06 |
Issuance Date |
2020-06-10 |
Abatement Due Date |
2020-06-22 |
Current Penalty |
2200.0 |
Initial Penalty |
3084.0 |
Final Order |
2021-01-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous. Location: 1420 58th Street, Brooklyn, NY; 1st floor. On or about 1/8/2020, a) Employees used an extension cord to energize equipment and the cord was missing the ground pin. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260416 E01 |
Issuance Date |
2020-06-10 |
Abatement Due Date |
2020-06-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-01-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. Location: 1420 58th Street, Brooklyn, NY; 1st floor. On or about 1/8/2020, a) The outer jacket of an extension cord was damaged and had exposed conductors. The extension cord was used to energize equipment. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2020-06-10 |
Current Penalty |
2200.0 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-07 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: 1420 58th Street, Brooklyn, NY; 1st floor. On or about 1/8/2020, a) A stairwell opening was not equipped with a top rail. Employees exposed to fall hazard of approximately 10 ft. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261053 B04 |
Issuance Date |
2020-06-10 |
Abatement Due Date |
2020-06-22 |
Current Penalty |
2100.0 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed. Location: 1420 58th Street, Brooklyn, NY; 1st floor. On or about 1/8/2020, a) An employee worked from an A-Frame ladder and the ladder was in its closed position leaning against the wall. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B13 |
Issuance Date |
2020-06-10 |
Abatement Due Date |
2020-06-22 |
Current Penalty |
2100.0 |
Initial Penalty |
3856.0 |
Final Order |
2021-01-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step. Location: 1420 58th Street, Brooklyn, NY; 1st floor. On or about 1/8/2020, a) An employee worked from the top step of an A-Frame ladder while conducting work in the ceiling. |
|
|