342517745
|
0215800
|
2017-08-03
|
SCRIBA FIRE DEPARTMENT 5618 NY ROUTE 104, OSWEGO, NY, 13126
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-08-03
|
Emphasis |
L: FALL
|
Case Closed |
2018-10-17
|
Related Activity
Type |
Referral |
Activity Nr |
1248267 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2017-11-08 |
Abatement Due Date |
2017-12-14 |
Current Penalty |
1000.0 |
Initial Penalty |
19520.0 |
Contest Date |
2017-12-08 |
Final Order |
2018-04-26 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 8/1/17: Workers were performing roofing work on a 4:12 pitch roof with a ground to eave height of 11 feet, without fall protection. Felder's Roofing & General Construction Corp was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 1073217 citation number 2 item number 1 and was affirmed as a final order on (1/29/16), with respect to a workplace located at Remington Art Museum, 311 Washington Street, Ogdensburg, NY. |
|
|
340732171
|
0215800
|
2015-06-24
|
FREDERIC REMINGTON ART MUSEUM, 311 WASHINGTON STREET, OGDENSBURG, NY, 13669
|
|
Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-24
|
Emphasis |
L: FALL
|
Case Closed |
2016-02-24
|
Related Activity
Type |
Referral |
Activity Nr |
995685 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 B05 II |
Issuance Date |
2015-08-10 |
Abatement Due Date |
2015-08-18 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2015-09-01 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end: a) Northwest corner of building, on or about 6-24-15: Two employees were working on a scaffold plank that was extended 5 feet beyond its support, exposing the employees to a fall hazard of 36 feet. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2015-08-10 |
Current Penalty |
0.0 |
Initial Penalty |
3850.0 |
Contest Date |
2015-09-01 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Northwest corner of building, on or about 6-24-15: Two employees were accessing a work platform on a roof via an extension ladder that was 20 inches above the landing surface, exposing the employees to a fall hazard of 33 feet. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260501 B13 |
Issuance Date |
2015-08-10 |
Abatement Due Date |
2015-08-18 |
Current Penalty |
5000.0 |
Initial Penalty |
19250.0 |
Contest Date |
2015-09-01 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Northwest corner of building, on or about 6-24-15: Two employees were working on a sloped roof (12:12 pitch) and were not protected from falls, exposing the employees to a fall hazard of 33 feet. FELDERS ROOFING & GENERAL CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OR A SIMILAR OCCUPATIONAL SAFETY AND HEALTH STANDARD, 1926.501(b)(11), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315849794, CITATION NUMBER 01, ITEM NUMBER 001a, ISSUED ON 2-10-12, WITH RESPECT TO A WORKPLACE LOCATED AT EMMA FLOWER TAYLOR MANSION, 241 CLINTON STREET, WATERTOWN NY, 13601. FELDERS ROOFING & GENERAL CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OR A SIMILAR OCCUPATIONAL SAFETY AND HEALTH STANDARD, 1926.503(b)(10), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 454694, CITATION NUMBER 01, ITEM NUMBER 001a, ISSUED ON 7-27-12, WITH RESPECT TO A WORKPLACE LOCATED AT 604 OLD LIVERPOOL ROAD, LIVERPOOL NY, 13088. ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19260503 A01 |
Issuance Date |
2015-08-10 |
Abatement Due Date |
2015-09-12 |
Current Penalty |
0.0 |
Initial Penalty |
19250.0 |
Contest Date |
2015-09-01 |
Final Order |
2016-01-29 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Northwest corner of building, on or about 6-24-15: One employees was working on a sloped roof (12:12 pitch), without fall protection, and without the training necessary for the employee to recognize the hazards associated with falls and his work, exposing the employee to a fall hazard of 33 feet. FELDERS ROOFING & GENERAL CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OR A SIMILAR OCCUPATIONAL SAFETY AND HEALTH STANDARD, 1926.503(a)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 454694, CITATION NUMBER 01, ITEM NUMBER 002, ISSUED ON 7-27-12, WITH RESPECT TO A WORKPLACE LOCATED AT 604 OLD LIVERPOOL ROAD, LIVERPOOL NY, 13088. FELDERS ROOFING & GENERAL CONSTRUCTION CORP. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OR A SIMILAR OCCUPATIONAL SAFETY AND HEALTH STANDARD, 1926.503(a)(1), WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 315849794, CITATION NUMBER 01, ITEM NUMBER 001b, ISSUED ON 2-10-12, WITH RESPECT TO A WORKPLACE LOCATED AT EMMA FLOWER TAYLOR MANSION, 241 CLINTON STREET, WATERTOWN NY, 13601. ABATEMENT DOCUMENTATION IS REQUIRED FOR THIS ITEM |
|
|
334546942
|
0215800
|
2012-06-05
|
604 OLD LIVERPOOL ROAD, LIVERPOOL, NY, 13088
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-06-05
|
Emphasis |
L: FALL
|
Case Closed |
2014-01-07
|
Related Activity
Type |
Complaint |
Activity Nr |
385291 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
462658 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B10 |
Issuance Date |
2012-07-27 |
Abatement Due Date |
2012-08-06 |
Current Penalty |
1065.0 |
Initial Penalty |
3850.0 |
Final Order |
2012-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and fuardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system: a) At the jobsite, on or about 6/5/12: Employees engaged in roofing work were not protected from falling by any approved means. Employees were exposed to falls of 17 feet to grade. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260502 F01 |
Issuance Date |
2012-07-13 |
Abatement Due Date |
2012-08-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2012-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(f)(1): Warning lines were not erected around all sides of the roof work area: a) At the jobsite, southwest side of the building, on or about 6/5/12: A warning line was not erected along the edge of the building where employees were dumping tear-off debris into dumpsters. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2012-07-27 |
Abatement Due Date |
2012-08-06 |
Current Penalty |
1065.0 |
Initial Penalty |
3850.0 |
Final Order |
2012-08-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: a) At the jobsite, on or about 6/5/12: Employees engaged in roofing work were not provided with training to recognize and avoid those hazards. |
|
|
315849794
|
0215800
|
2011-11-07
|
EMMA FLOWER TAYLOR MANSION, 241 CLINTON ST, WATERTOWN, NY, 13601
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2011-12-07
|
Emphasis |
L: FALL
|
Case Closed |
2012-11-08
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B11 |
Issuance Date |
2012-02-10 |
Abatement Due Date |
2012-02-15 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Contest Date |
2012-03-23 |
Final Order |
2012-10-09 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2012-02-10 |
Abatement Due Date |
2012-03-15 |
Contest Date |
2012-03-23 |
Final Order |
2012-10-09 |
Nr Instances |
7 |
Nr Exposed |
7 |
Gravity |
05 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260602 C01 II |
Issuance Date |
2012-02-10 |
Abatement Due Date |
2012-03-15 |
Current Penalty |
500.0 |
Initial Penalty |
500.0 |
Contest Date |
2012-03-23 |
Final Order |
2012-10-09 |
Nr Instances |
7 |
Nr Exposed |
7 |
Gravity |
05 |
|
|