Name: | G & Y CONTRACTOR INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 12 Oct 2005 (20 years ago) |
Entity Number: | 3267285 |
ZIP code: | 10591 |
County: | Westchester |
Place of Formation: | New York |
Address: | PO BOX 705, SLEEPY HOLLOW, NY, United States, 10591 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | PO BOX 705, SLEEPY HOLLOW, NY, United States, 10591 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
051012000043 | 2005-10-12 | CERTIFICATE OF INCORPORATION | 2005-10-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
335992780 | 0216000 | 2012-08-13 | 20 ORCHARD DRIVE, TARRYTOWN, NY, 10591 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 579561 |
Safety | Yes |
Type | Complaint |
Activity Nr | 508790 |
Safety | Yes |
Type | Inspection |
Activity Nr | 579218 |
Safety | Yes |
Type | Inspection |
Activity Nr | 606298 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2013-02-05 |
Current Penalty | 2800.0 |
Initial Penalty | 2800.0 |
Final Order | 2013-03-28 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: Location: Jobsite, 20 Orchard Drive a) Employees were installing a residential roof on a steep sloped roof without any fall protection, thus exposing employees to the hazard of falling up to three floors to the ground below on or about 08/13/12. |
Date of last update: 29 Mar 2025
Sources: New York Secretary of State