339885220
|
0215800
|
2014-08-06
|
825 TEAL STREET, SYRACUSE, NY, 13201
|
|
Inspection Type |
Prog Related
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-08-06
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2019-06-11
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
2200.0 |
Initial Penalty |
2200.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:(a)(LOCATION)(IDENTIFY SPECIFIC EQUIPMENT AND/OR CONDITIONS)(DESCRIBE HAZARDS WHERE NECESSARY) a) At the jobsite, on or about 8/6/14: An employee was using an extension cord to power tools, where that cords plug was pulled free from the cord. Abatement certification must be submitted for this item. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 I |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 8/6/14: An employee was using an extension cord to power tools, where that cords plug was pulled free from the cord and that power source was not GFI protected. Abatement documentation must be submitted for this item. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19261053 B22 |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
3080.0 |
Initial Penalty |
3080.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(22): Employees using ladders were carrying objects or loads that could cause the employee to lose balance and fall: a) At the jobsite, on or about 8/6/14: An employee was using an extension ladder to access a roof surface approximately 25 feet from ground while carrying a full sheet of plywood to that roof surface. Abatement documentation must be submitted for this item. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19261053 B15 |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: a) At the jobsite, on or about 8/6/14: An employee was using an extension ladder to access a roof surface approximately 25 feet from ground where that ladder had multiple bent rungs and had not been inspected by a competent person. Abatement certification must be submitted for this item. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
6160.0 |
Initial Penalty |
6160.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) At the jobsite, on the roof, on or about 8/6/14: An employee was on a 10:12 pitch roof, approximately 25 feet from ground, without fall protection of any kind. JP Improvement was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.501(b)(13), which was contained in OSHA inspection number 943072 citation number 1, item number 1a and was affirmed as a final order on 11/6/13, with respect to a workplace located at 900 Milton Avenue, Syracuse, NY. Abatement documentation must be submitted for this item. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-08-26 |
Abatement Due Date |
2014-09-03 |
Current Penalty |
4400.0 |
Initial Penalty |
4400.0 |
Final Order |
2014-10-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, accessing the roof, on or about 8/6/14: An employee was using an extension ladder to access a roof approximately 25 feet from ground where that ladder did not extend at least 3 feet above that upper landing. JP Improvement was previously cited for a violation of this occupational safety and health standard or its equivalent standard CFR 1926.1053(b)(1), which was contained in OSHA inspection number 943072 citation number 1, item number 1b and was affirmed as a final order on 11/6/13, with respect to a workplace located at 900 Milton Avenue, Syracuse, NY. Abatement documentation must be submitted for this item. |
|
|
339874729
|
0215800
|
2014-07-30
|
825 TEALL AVENUE, SYRACUSE, NY, 13201
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-07-30
|
Emphasis |
L: FALL
|
Case Closed |
2019-02-28
|
Related Activity
Type |
Complaint |
Activity Nr |
900719 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260503 A01 |
Issuance Date |
2014-09-05 |
Abatement Due Date |
2014-09-20 |
Current Penalty |
2200.0 |
Initial Penalty |
2200.0 |
Final Order |
2014-11-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Entire roof, on or about 7-30-14: Two employees were working on a steep roof without the training necessary for those employees to recognize the hazards associated with falls and their work, exposing the employees to a fall hazard of 26 feet. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19260501 B13 |
Issuance Date |
2014-09-05 |
Current Penalty |
4400.0 |
Initial Penalty |
4400.0 |
Final Order |
2014-11-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) North side of roof, on or about 7-30-14: Two employees were working on a 10:12 pitch roof, without fall protection, exposing the employees to a fall hazard of 26 feet. |
|
Citation ID |
02002 |
Citaton Type |
Repeat |
Standard Cited |
19261053 B01 |
Issuance Date |
2014-09-05 |
Current Penalty |
4400.0 |
Initial Penalty |
4400.0 |
Final Order |
2014-11-14 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) North side of roof, on or about 7-30-14: Two employees were using a portable ladder for access to a roof, which was not extended 3 feet above the landing surface, exposing the employee to a fall hazard of 27 feet 6 inches. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2015-04-22 |
Abatement Due Date |
2015-05-11 |
Current Penalty |
440.0 |
Initial Penalty |
440.0 |
Final Order |
2015-05-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) At the jobsite, on or about 12/17/2014: The employer did not provide abatement certification for Citation 1, Item 001issued on September 5, 2014. An abatement demand letter was sent to the employer on November 5, 2014. Abatement certification is required for this item. |
|
|
339430720
|
0215800
|
2013-10-09
|
900 MILTON AVENUE, SYRACUSE, NY, 13204
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-10-09
|
Emphasis |
L: FALL
|
Case Closed |
2016-07-26
|
Related Activity
Type |
Complaint |
Activity Nr |
856299 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2013-10-22 |
Current Penalty |
1020.0 |
Initial Penalty |
1700.0 |
Final Order |
2013-11-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 900 Milton Avenue - On or about 9 October, 2013 - Employees were working on a residential roof above 6 feet without the use of personal fall protection. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2013-10-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2013-11-06 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladders length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) 900 Milton Avenue - On or about 9 October, 2013 - Employees were using an extension ladder to access the upper landing surface that did not have the side rails extended a minimum of 3 feet above the upper landing surface. |
|
|