Search icon

TOMRIC SYSTEMS, INC.

Company Details

Name: TOMRIC SYSTEMS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 24 Oct 2005 (19 years ago)
Entity Number: 3272080
ZIP code: 14207
County: Erie
Place of Formation: New York
Address: 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, United States, 14207

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

form 5500

Plan Name Plan Year EIN/PN Received Sponsor Total number of participants
TOMRIC SYSTEMS INC. 401(K) PROFIT SHARING PLAN 2023 203788195 2024-09-12 TOMRIC SYSTEMS, INC. 131
File View Page
Three-digit plan number (PN) 001
Effective date of plan 1992-04-01
Business code 326100
Sponsor’s telephone number 7168546050
Plan sponsor’s address 85 RIVER ROCK DRIVE, BUFFALO, NY, 14207

Signature of

Role Plan administrator
Date 2024-09-12
Name of individual signing DAWN DELZER
Valid signature Filed with authorized/valid electronic signature
Role Employer/plan sponsor
Date 2024-09-12
Name of individual signing DAWN DELZER
Valid signature Filed with authorized/valid electronic signature

Chief Executive Officer

Name Role Address
THOMAS ELSINGHORST Chief Executive Officer 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, United States, 14207

DOS Process Agent

Name Role Address
TOMRIC SYSTEMS, INC. DOS Process Agent 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, United States, 14207

History

Start date End date Type Value
2024-09-18 2024-09-18 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)
2023-02-08 2024-09-18 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Service of Process)
2023-02-08 2024-09-18 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)
2023-02-08 2023-02-08 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)
2023-02-08 2024-09-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2019-10-02 2023-02-08 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)
2017-10-03 2023-02-08 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Service of Process)
2017-10-03 2019-10-02 Address 85 RIVER ROCK DR, SUITE 202, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)
2009-10-19 2017-10-03 Address 85 RIVER ROCK DR, 201, BUFFALO, NY, 14207, USA (Type of address: Principal Executive Office)
2009-10-19 2017-10-03 Address 85 RIVER ROCK DR, 201, BUFFALO, NY, 14207, USA (Type of address: Chief Executive Officer)

Filings

Filing Number Date Filed Type Effective Date
240918003634 2024-09-18 BIENNIAL STATEMENT 2024-09-18
230208001494 2023-02-08 BIENNIAL STATEMENT 2021-10-01
191002061977 2019-10-02 BIENNIAL STATEMENT 2019-10-01
171003006014 2017-10-03 BIENNIAL STATEMENT 2017-10-01
160920006098 2016-09-20 BIENNIAL STATEMENT 2015-10-01
131015007091 2013-10-15 BIENNIAL STATEMENT 2013-10-01
111019002014 2011-10-19 BIENNIAL STATEMENT 2011-10-01
091019002135 2009-10-19 BIENNIAL STATEMENT 2009-10-01
071009002573 2007-10-09 BIENNIAL STATEMENT 2007-10-01
051024000166 2005-10-24 CERTIFICATE OF INCORPORATION 2005-10-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347673923 0213600 2024-08-08 85 RIVER ROCK DRIVE #202, BUFFALO, NY, 14207
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2024-08-08
Emphasis N: AMPUTATE
Case Closed 2024-08-08

Related Activity

Type Inspection
Activity Nr 1722699
Safety Yes
347226995 0213600 2024-01-23 85 RIVER ROCK DRIVE #202, BUFFALO, NY, 14207
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-01-23
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2024-04-11

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C06 I
Issuance Date 2024-03-19
Abatement Due Date 2024-04-10
Current Penalty 4000.0
Initial Penalty 6857.0
Final Order 2024-03-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 01/23/2024, throughout the establishment, the employer did not conduct periodic inspections of the Lockout/Tagout procedures for employees that perform servicing activities such as, but not limited to doing maintenance on GN machines. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100212 A02
Issuance Date 2024-03-19
Abatement Due Date 2024-04-10
Current Penalty 2000.0
Initial Penalty 5485.0
Final Order 2024-03-25
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: a) On or about 01/23/2024, in the Heavy Gauge Sanding Area, the belt sander did not have guards that were affixed to the machine to prevent bypassing, removing, or tampering. The side guard of the belt sander is left open while employees sand parts exposing them to caught-by hazards. ABATEMENT DOCUMENTATION REQUIRED
Citation ID 02001
Citaton Type Repeat
Standard Cited 19100147 C04 I
Issuance Date 2024-03-19
Abatement Due Date 2024-04-10
Current Penalty 12000.0
Initial Penalty 16134.0
Final Order 2024-03-25
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 01/23/2024 in the Thin Gauge Forming Area; where energy control procedures (lockout) were not used while employees were unjamming GN thermoforming machines (GN 3625DX & GN 3021C). Exposing employees to caught-by hazards. ABATEMENT DOCUMENTATION REQUIRED Tomric Systems, Inc. was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1436722, citation number 1, item number 1, and was affirmed as a final order on 12/09/2019, with respect to a workplace located at 85 River Rock Dr. #202, Buffalo NY 14207.
345250849 0213600 2021-04-12 85 RIVER ROCK DRIVE #202, BUFFALO, NY, 14207
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-04-12
Emphasis N: AMPUTATE
Case Closed 2021-04-12

Related Activity

Type Inspection
Activity Nr 1436722
Safety Yes
344367222 0213600 2019-10-10 85 RIVER ROCK DRIVE #202, BUFFALO, NY, 14207
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2019-11-07
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2020-08-14

Related Activity

Type Referral
Activity Nr 1507277
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C04 I
Issuance Date 2019-11-13
Abatement Due Date 2020-01-20
Current Penalty 5500.0
Initial Penalty 9282.0
Final Order 2019-12-09
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(i): Procedures were not utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 10/08/2019 in the production area; where energy control procedures (lockout) were not used while employees were unjamming tray making machines (GN 3021 C). ABATEMENT DOCUMENTATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100147 C07 I A
Issuance Date 2019-11-13
Abatement Due Date 2020-01-20
Current Penalty 5500.0
Initial Penalty 9282.0
Final Order 2019-12-09
Nr Instances 2
Nr Exposed 7
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: a) On or about 10/08/2019 in the production area; where machine operators were performing servicing and/or maintenance (unjamming machines - such as, but not limited to: removing stuck parts from tray making machines) and the machine operators were not trained to the "authorized" level. ABATEMENT DOCUMENTION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19100212 A03 II
Issuance Date 2019-11-13
Abatement Due Date 2020-01-20
Current Penalty 5500.0
Initial Penalty 9282.0
Final Order 2019-12-09
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On or about 10/08/2019 in the production area; where the safety interlocks (proximity switches) on the point of operation guard for the "GN 3021 C" tray making machine were broken, allowing the machine to cycle with the guard "open". b) On or about 11/07/2019 in the production area; where the shear blade and point of operation on the Roper-Whitney shear were not guarded. ABATEMENT DOCUMENTATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100178 Q07
Issuance Date 2019-11-13
Abatement Due Date 2020-01-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-09
Nr Instances 1
Nr Exposed 3
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.178(q)(7): Industrial trucks were not examined, at least daily, before being placed in service: a) On or about 11/07/2019 in the warehouse area; where two powered industrial vehicles are used daily to move materials and load trucks. ABATEMENT CERTIFICATION REQUIRED
313652430 0213600 2009-08-28 85 RIVER ROCK DRIVE SUITE 202, BUFFALO, NY, 14207
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2009-09-01
Emphasis N: AMPUTATE, S: AMPUTATIONS
Case Closed 2009-10-30

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100147 C07 IA
Issuance Date 2009-09-21
Abatement Due Date 2009-10-24
Current Penalty 525.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 5
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100219 B01
Issuance Date 2009-09-21
Abatement Due Date 2009-09-24
Current Penalty 700.0
Initial Penalty 700.0
Nr Instances 1
Nr Exposed 2
Gravity 02
Citation ID 01003
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2009-09-21
Abatement Due Date 2009-09-24
Current Penalty 525.0
Initial Penalty 525.0
Nr Instances 1
Nr Exposed 4
Gravity 01

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
4755927104 2020-04-13 0296 PPP 85 River Rock Dr, BUFFALO, NY, 14207-2169
Loan Status Date 2021-03-19
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 311555
Loan Approval Amount (current) 311555
Undisbursed Amount 0
Franchise Name -
Lender Location ID 56102
Servicing Lender Name KeyBank National Association
Servicing Lender Address 127 Public Sq, CLEVELAND, OH, 44114-1217
Rural or Urban Indicator U
Hubzone Y
LMI Y
Business Age Description Unanswered
Project Address BUFFALO, ERIE, NY, 14207-2169
Project Congressional District NY-26
Number of Employees 28
NAICS code 423830
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 56102
Originating Lender Name KeyBank National Association
Originating Lender Address CLEVELAND, OH
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 313659.96
Forgiveness Paid Date 2021-02-12

Date of last update: 29 Mar 2025