OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
332825447 0216000 2012-03-22 339 HEATHCOTE RD, SCARSDALE, NY, 10583
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2012-04-04
Emphasis L: FALL
Case Closed 2016-08-02

Related Activity

Type Inspection
Activity Nr 280637
Safety Yes
Type Inspection
Activity Nr 280834
Safety Yes
Type Inspection
Activity Nr 280554
Safety Yes
Type Inspection
Activity Nr 282564
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2012-05-18
Abatement Due Date 2012-06-11
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-06-15
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. On or about 3/22/2012, Job Site a) The employer did not provide safety and health training as required by the standard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 II
Issuance Date 2012-05-18
Current Penalty 1800.0
Initial Penalty 1800.0
Final Order 2012-06-15
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(ii): One stairrail system along each unprotected side or edge. Note: When the top edge of a stairrail system also serves as a handrail, paragraph (c)(7) of this section applies. On or about 3/22/2012, Basement a) The employees used the stairs which did not have a stairrail system on the open, ascending side.