Search icon

MID ISLAND STUCCO SYSTEMS, INC.

Company Details

Name: MID ISLAND STUCCO SYSTEMS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 14 Dec 2005 (19 years ago)
Entity Number: 3292845
ZIP code: 11558
County: Nassau
Place of Formation: New York
Address: 221 LONG BEACH RD, ISLAND PARK, NY, United States, 11558

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 221 LONG BEACH RD, ISLAND PARK, NY, United States, 11558

Chief Executive Officer

Name Role Address
WALTES QUINTANELLA Chief Executive Officer 221 LONG BEACH RD, ISLAND PARK, NY, United States, 11558

History

Start date End date Type Value
2005-12-14 2008-01-02 Address 221 LONG BEACH ROAD, ISLAND PARK, NY, 11558, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
091221002705 2009-12-21 BIENNIAL STATEMENT 2009-12-01
080102002590 2008-01-02 BIENNIAL STATEMENT 2007-12-01
051214000564 2005-12-14 CERTIFICATE OF INCORPORATION 2005-12-14

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
339484842 0214700 2013-11-14 3542 WOODWARD ST., OCEANSIDE, NY, 11572
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2013-11-14
Emphasis L: FALL, L: SANDY, P: FALL
Case Closed 2019-07-08

Related Activity

Type Inspection
Activity Nr 948520
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2014-04-11
Abatement Due Date 2014-04-17
Current Penalty 1540.0
Initial Penalty 3080.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) Worksite, 3542 Woodward St., Oceanside NY - Employees were applying stucco on a residential home while walking and working on a fabricated frame scaffold. The frame of the scaffold was touching the energized 220V power line; on or about 11/14/13. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2014-04-11
Abatement Due Date 2014-04-17
Current Penalty 1100.0
Initial Penalty 2200.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet or more above lower levels was not protected by guardrail systems, safety net systems, or personal fall arrest systems, nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502. a) Worksite - Employees were applying stucco to a two story residential home. The employees were not protected from falling approximately 12ft to the ground below; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260451 B01
Issuance Date 2014-04-11
Abatement Due Date 2014-04-17
Current Penalty 2200.0
Initial Penalty 4400.0
Final Order 2014-07-02
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Worksite, Exterior - Employees were working on the first tier of a fabricated frame scaffold. The employees were working on an area of the scaffold that had three planks installed; on or about 11/14/13. b) Worksite, Exterior - Employees were working on the second tier of a fabricated frame scaffold. The employees were working on an area of the scaffold that had three planks installed; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. Mid Island Stucco System Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 311137954 citation number 1 item number 1 and was affirmed as a final order on 10/2/09, with respect to a workplace located at 2210 Long Beach Rd. Oceanside NY 11572.
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260451 E01
Issuance Date 2014-04-11
Abatement Due Date 2014-04-17
Current Penalty 2200.0
Initial Penalty 4400.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Worksite, 3542 Woodward St. Oceanside NY - Employees were applying stucco to a two story residential home while working from a fabricated frame scaffold. The employees were climbing the crossbraces to gain access to the scaffold; on or about 11/14/13. Mid Island Stucco System Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(e)(1), which was contained in OSHA inspection number 311137954 citation number 1 item number 2 and was affirmed as a final order on 10/2/09, with respect to a workplace located at 2210 Long Beach Rd. Oceanside NY 11572.
Citation ID 02003
Citaton Type Repeat
Standard Cited 19260451 G01 VII
Issuance Date 2014-04-11
Abatement Due Date 2014-04-17
Current Penalty 2200.0
Initial Penalty 4400.0
Final Order 2014-07-02
Nr Instances 2
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) Worksite, 3542 Woodward St. Oceanside NY - Employees were applying stucco to a two story residential home while working on the second tier of a fabricated frame scaffold. The employees were not protected from falling approximately 12ft to the ground below; on or about 11/14/13. b) Worksite, 3542 Woodward St. Oceanside NY - Employees were applying stucco to a two story residential home while working from a scaffolding plank on the roof of a portico. The employees were not protected from falling approximately 12ft to the ground below; on or about 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. Mid Island Stucco System Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1)(vii), which was contained in OSHA inspection number 311137954 citation number 1 item number 3 and was affirmed as a final order on 10/2/09, with respect to a workplace located at 2210 Long Beach Rd. Oceanside NY 11572.
Citation ID 03001A
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2014-04-11
Abatement Due Date 2014-05-29
Current Penalty 220.0
Initial Penalty 440.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met (Construction Reference: 1926.59): a) Worksite, North - Employees applying stucco use materials such as, but not limited to, Senerflex Fine Maxi White. A written hazard communication program was not in place; on, or about, 11/14/13. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. ABATEMENT NOTE: The written Hazard Communication Program must include descriptions of how the following program elements, required by this regulation, will be developed, implemented, and conveyed to the employer's employee(s) who are exposed to hazardous materials: a. Labeling and other forms or warning: Labels shall include at least the identity of the hazardous chemical(s), the appropriate hazard warnings, the target organs, and the name and address of the chemical manufacturer, importer or other responsible party; b. A list or inventory of all hazardous materials known to be present in the workplace must be compiled and be maintained as part of the employer's written Hazard Communication Program; c. Material Safety Data Sheets (MSDSs) for all materials used by employee(s) in the workplace must be maintained and readily available all employee(s) on all shifts. d. The employer's Hazardous Materials Information and Training Program must be based upon the employer's written Hazard Communication Program. The training for employee(s) must include at least: Methods and observation that may be used to detect the presence or release of hazardous chemicals in the work area. The physical and health hazards of the chemicals in the work area. The measures employee(s) can take to protect themselves, such as, specific procedures, appropriate work practices, emergency procedures, and personal protective equipment to be used. The details of the employer's Hazard Communication Program including an explanation of the labeling systems used, Material Safety Data Sheets and how employees can obtain and use the appropriate hazard information; e. Methods used to inform employees of the hazards associated with non routine tasks must also be addressed in the employer's written program; and f. The employer's written Hazard Communication Program must be made available upon request. For Multi Employer Work places, the employer's Written Hazard Communication Program must also specifically address how: a. Material Safety Data Sheets for each hazardous material on the job site will be provided to other employers in the event the other employer's employee(s) may be exposed to these materials. b. The methods the employer will use to inform other employer(s) of any precautionary measures that need to be taken to protect employee(s) during normal operating conditions and in foreseeable emergencies. c. The methods the employer will use to inform the other employer(s) of the labeling system used in the workplace.
Citation ID 03002B
Citaton Type Other
Standard Cited 19101200 G08
Issuance Date 2014-04-11
Abatement Due Date 2014-05-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not ensure that material safety data sheets were readily accessible to the employees in their work area during each work shift: a) Worksite - Employees applying stucco use materials such as, but not limited to, Senerflex Fine Maxi Whit. Material safety data sheets were not available; on, or about, 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 03003C
Citaton Type Other
Standard Cited 19101200 H01
Issuance Date 2014-04-11
Abatement Due Date 2014-05-29
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2014-07-02
Nr Instances 1
Nr Exposed 4
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Worksite - Employees applying stucco use materials such as, but not limited to, Senerflex Fine Maxi White. A training program was not in place; on, or about, 11/14/13. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
311137954 0214700 2009-06-24 1187 SUNRISE HIGHWAY, COPIAGUE, NY, 11726
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2009-06-24
Emphasis S: COMMERCIAL CONSTR, S: FALL FROM HEIGHT, L: FALL
Case Closed 2011-10-05

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2009-07-16
Abatement Due Date 2009-07-22
Current Penalty 1200.0
Initial Penalty 2000.0
Nr Instances 2
Nr Exposed 3
Gravity 10
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2009-07-16
Abatement Due Date 2009-07-22
Current Penalty 1200.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 3
Gravity 10
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2009-07-16
Abatement Due Date 2009-07-22
Current Penalty 1200.0
Initial Penalty 2000.0
Nr Instances 1
Nr Exposed 3
Gravity 10
Citation ID 02001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2009-07-16
Abatement Due Date 2009-07-22
Current Penalty 1800.0
Initial Penalty 3000.0
Nr Instances 1
Nr Exposed 4
Gravity 01
Citation ID 02002
Citaton Type Repeat
Standard Cited 19260454 C
Issuance Date 2009-07-16
Abatement Due Date 2009-08-04
Current Penalty 3000.0
Initial Penalty 5000.0
Nr Instances 1
Nr Exposed 5
Gravity 03
311134993 0214700 2008-08-18 832 CHANNEL DRIVE, LIDO BEACH, NY, 11561
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2008-08-18
Emphasis S: FALL FROM HEIGHT, L: FALL, S: RESIDENTIAL CONSTR
Case Closed 2009-09-30

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260100 A
Issuance Date 2008-08-22
Abatement Due Date 2008-08-27
Current Penalty 1200.0
Initial Penalty 1200.0
Contest Date 2008-09-09
Final Order 2008-12-01
Nr Instances 1
Nr Exposed 3
Gravity 01
Citation ID 01002
Citaton Type Repeat
Standard Cited 19260451 B01
Issuance Date 2008-08-22
Abatement Due Date 2008-08-28
Current Penalty 4000.0
Initial Penalty 4000.0
Contest Date 2008-09-09
Final Order 2008-12-01
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01003
Citaton Type Repeat
Standard Cited 19260451 E01
Issuance Date 2008-08-22
Abatement Due Date 2008-08-28
Current Penalty 4000.0
Initial Penalty 4000.0
Contest Date 2008-09-09
Final Order 2008-12-01
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01004A
Citaton Type Repeat
Standard Cited 19260451 G01 VII
Issuance Date 2008-08-22
Abatement Due Date 2008-08-28
Current Penalty 4000.0
Initial Penalty 4000.0
Contest Date 2008-09-09
Final Order 2008-12-01
Nr Instances 1
Nr Exposed 1
Gravity 10
Citation ID 01004B
Citaton Type Repeat
Standard Cited 19260454 C
Issuance Date 2008-08-22
Abatement Due Date 2008-09-11
Contest Date 2008-09-09
Final Order 2008-12-01
Nr Instances 1
Nr Exposed 3
Gravity 10
307633610 0214700 2006-03-17 2265 WILLOW STREET, WANTAGH, NY, 11793
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2006-03-17
Emphasis L: FALL
Case Closed 2007-03-13

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2006-05-03
Abatement Due Date 2006-05-08
Current Penalty 200.0
Initial Penalty 450.0
Nr Instances 1
Nr Exposed 4
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2006-05-03
Abatement Due Date 2006-05-08
Current Penalty 450.0
Initial Penalty 750.0
Nr Instances 2
Nr Exposed 4
Gravity 03
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2006-05-03
Abatement Due Date 2006-05-08
Current Penalty 450.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 4
Gravity 03
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2006-05-03
Abatement Due Date 2006-05-08
Current Penalty 450.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 4
Gravity 03
Citation ID 01005
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2006-05-03
Abatement Due Date 2006-05-22
Current Penalty 450.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 4
Gravity 03