Name: | WEITZ CONSTRUCTION INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 20 Dec 2005 (19 years ago) |
Entity Number: | 3294883 |
ZIP code: | 10038 |
County: | Queens |
Place of Formation: | New York |
Address: | 45 JOHN STREET, SUITE 711, NEW YORK, NY, United States, 10038 |
Contact Details
Phone +1 718-803-3755
Shares Details
Shares issued 20000
Share Par Value 1
Type PAR VALUE
Name | Role | Address |
---|---|---|
SPIEGEL & UTRERA, P.A. P.C. | Agent | 45 JOHN STREET, SUITE 711, NEW YORK, NY, 10038 |
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 45 JOHN STREET, SUITE 711, NEW YORK, NY, United States, 10038 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
1232741-DCA | Active | Business | 2006-07-11 | 2025-02-28 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
051220000107 | 2005-12-20 | CERTIFICATE OF INCORPORATION | 2005-12-20 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
3571727 | TRUSTFUNDHIC | INVOICED | 2022-12-23 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3571728 | RENEWAL | INVOICED | 2022-12-23 | 100 | Home Improvement Contractor License Renewal Fee |
3295370 | TRUSTFUNDHIC | INVOICED | 2021-02-11 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
3295371 | RENEWAL | INVOICED | 2021-02-11 | 100 | Home Improvement Contractor License Renewal Fee |
2944458 | RENEWAL | INVOICED | 2018-12-14 | 100 | Home Improvement Contractor License Renewal Fee |
2944457 | TRUSTFUNDHIC | INVOICED | 2018-12-14 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2522588 | RENEWAL | INVOICED | 2016-12-29 | 100 | Home Improvement Contractor License Renewal Fee |
2522587 | TRUSTFUNDHIC | INVOICED | 2016-12-29 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1932161 | TRUSTFUNDHIC | INVOICED | 2015-01-06 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
1932162 | RENEWAL | INVOICED | 2015-01-06 | 100 | Home Improvement Contractor License Renewal Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345238893 | 0213600 | 2021-04-07 | 2 LEDGESTONE PASS, BROCKPORT, NY, 14420 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2021-07-20 |
Current Penalty | 1691.25 |
Initial Penalty | 2255.0 |
Final Order | 2021-08-04 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or about 04/07/21 at the Stonebriar Glen located on 2 Ledgestone Pass, in Brockport, New York, the employer did not provide fall protection for employees exposing them to falling 25 feet to the lower level. Employees were engaged in residential construction and working on the roof surface. |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2018-04-13 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2018-07-13 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2018-06-21 |
Current Penalty | 1602.0 |
Initial Penalty | 2136.0 |
Final Order | 2018-07-17 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 04/13/18, Nathaniel Poole Trail, in Brockport, New York, employees working on a steep roof (new install)with a slope/pitch of 6/12, were not protected from falling 12 feet to ground level with fall protection. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2018-06-21 |
Current Penalty | 1602.0 |
Initial Penalty | 2136.0 |
Final Order | 2018-07-17 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 04/13/18, Nathaniel Poole Trail, in Brockport, New York, a ladder in use did not extend at least 3 feet above the roof landing where workers were installing roof sheathing and performing framing work. NO ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 29 Mar 2025
Sources: New York Secretary of State