346676414
|
0213100
|
2023-05-03
|
108 SOUTH WATER ST., NEWBURGH, NY, 12550
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-05-03
|
Related Activity
Type |
Inspection |
Activity Nr |
1665686 |
Safety |
Yes |
|
Type |
Referral |
Activity Nr |
2025459 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2023-07-25 |
Abatement Due Date |
2023-07-31 |
Current Penalty |
2902.25 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) On and before 5/3/2023, at facility, for the machine operator working around wood dust and cleaning with a rag and lacquer thinner, to clean the blades and wheels inside the Edgeband machine. The employer did not enforce the requirement to use eye protection. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2023-07-25 |
Abatement Due Date |
2023-07-31 |
Current Penalty |
2321.8 |
Initial Penalty |
3572.0 |
Final Order |
2023-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): Employer did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes: (a) On and before 5/3/2023, at facility, for the machine operator cleaning using degraded gloves, a rag, and lacquer thinner, to clean the blades and wheels inside the Edgeband machine. The employer did not use the appropriate personal protective equipment for the protection of the extremities such as, but not limited to, gloves that are compatible with chemicals in use. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2023-07-25 |
Abatement Due Date |
2023-08-28 |
Current Penalty |
2902.25 |
Initial Penalty |
4465.0 |
Final Order |
2023-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) On and before 5/3/2023, at facility, for the machine operator working around wood dust and cleaning with a rag and lacquer thinner, to clean the blades and wheels inside the Edgeband machine. Employer did not develop and implement a hazard communication program. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2023-07-25 |
Abatement Due Date |
2023-07-31 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: (a) On and before 5/3/2023, at facility, for the machine operator working around wood dust and cleaning with a rag and lacquer thinner, to clean the blades and wheels inside the Edgeband machine. The employer did not have SDS's. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2023-07-25 |
Abatement Due Date |
2023-08-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2023-08-02 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On and before 5/3/2023, at facility, for the machine operator working around wood dust and cleaning with a rag and lacquer thinner, to clean the blades and wheels inside the Edgeband machine. Employer did not provide employees with hazard communication training associated to chemicals they work with. |
|
|
346656861
|
0213100
|
2023-04-25
|
108 SOUTH WATER ST., NEWBURGH, NY, 12550
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-25
|
Related Activity
Type |
Complaint |
Activity Nr |
2021711 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1667641 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2024-02-16 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
4 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards from combustible wood dust: a) Skill Dust Collector Area - On or prior to May 3, 2023, an employee operating the Biesse Skill 15.36 G FT CNC machine had to stand approximately 6 feet away from the dust collection system, and three out of the four dust collection bags are changed out every couple months exposing the employee to caught-in hazards in the event of a fire or explosion. The dust collector system and associated components, including bulk sawdust storage bin, were not installed and maintained to protect employees from fire and explosion hazards from combustible wood dust. b) Homag - Sawteq B-400 Dust Collector Area - On or prior to May 3, 2023, the dust collector for the Homag Sawteq B-400 profiLine Horizontal panel saw with pressure beam (Machine number 0-240-73-7266) was located approximately 14 feet from the exit door exposing employees to caught-in hazards in the event of a fire or explosion. The dust collection bags were changed out every few days to every few weeks. The dust collector system and associated components, including bulk sawdust storage bin, were not installed and maintained to protect employees from fire and explosion hazards from combustible wood dust. c) Homag Edge Bander Dust Collector Area - On or prior to May 3, 2023, the dust collection bags for the Homag Edge Bander dust collector were changed every 3 months exposing employees to caught-in hazards in the event of a fire or explosion. The dust collector system and associated components, including bulk sawdust storage bin, were not maintained to protect employees from fire and explosion hazards from combustible wood dust. d) Weeke - Grizzly Dust Collector Area - On or prior to May 3, 2023, the dust collection bag for the Weeke machine for boring, dowel and hardware inserting (Machine number 0-253-80-3401) was changed out as needed approximately every 4 weeks, with an employee operating the machine approximately 4 feet away from the dust collector exposing the employee to caught-in hazards in the event of a fire or explosion. The dust collector system and associated components, including bulk sawdust storage bin, were not installed and maintained to protect employees from fire and explosion hazards from combustible wood dust. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100036 G02 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
0.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. a) Facility - On or about April 25, 2023, an exit access was approximately 7 inches wide due to being obstructed exposing employees to caught-in hazards in the event of a fire. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): a) Homag Edge Bander Area - On or prior to April 25, 2023, an employee that operates the Homag Edge Bander wore gloves that would get caught in the machine while operating the machine. No PPE Hazard assessment was conducted to determine appropriate use of gloves on when operating this machine. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
0.0 |
Initial Penalty |
2678.0 |
Final Order |
2023-11-21 |
Nr Instances |
2 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1):Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) Facility - On or about April 25, 2023, employees used a DeWalt (DCF885) drill without wearing eye protection when drilling holes in cabinets pieces exposing them to struck-by hazards. b) Facility - On or about April 25, 2023, employees used a Ridgid nail gun (LV21132NN 5580) without wearing eye protection when putting cabinet pieces together exposing them to struck-by hazards. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100147 C01 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Homag Edge Bander Area - On or prior to April 25, 2023, an employee performs maintenance activities on the Homag Edge Bander Machine with both air and electric energy sources present on the machine. The maintenance tasks performed by the employee on the Homag Edge Bander include tasks such as, but not limited to, cleaning blades and wheels by using rags with their hands right on the blades without performing Lockout/Tagout. The employer did not develop a Lockout/Tagout Program consisting of employee training, energy control procedures, and periodic inspections. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100157 C01 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
1606.8 |
Initial Penalty |
2678.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Complaint |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.157(c)(1):Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Facility - On or about April 25, 2023, portable fire extinguishers were not mounted. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i):The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Facility - On or prior to April 25, 2023, employees operated a Nissan Forklift (Mast: 3F 475) without being trained and evaluated to ensure safe operation. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100303 B02 |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
3750.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Facility - On or about May 3, 2023, an extension cord was used to daisy chain a refrigerator and microwave together. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100303 B07 I |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
0.0 |
Initial Penalty |
6250.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) Facility - On or about May 3, 2023, Mail Panel 2 Feed From Main Panel 1 electrical box had a missing knockout. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2023-10-18 |
Abatement Due Date |
2023-10-24 |
Current Penalty |
535.8 |
Initial Penalty |
893.0 |
Final Order |
2023-11-21 |
Nr Instances |
1 |
Nr Exposed |
16 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent: a) Facility - On or about April 25, 2023, the employer did not keep OSHA 300 Logs, 301s, 300A Forms or equivalent. |
|
|
344307228
|
0213100
|
2019-09-13
|
108 SOUTH WATER ST., NEWBURGH, NY, 12550
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2019-09-17
|
Case Closed |
2023-09-14
|
Related Activity
Type |
Referral |
Activity Nr |
1497865 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100107 B05 I |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2021-06-03 |
Current Penalty |
1156.5 |
Initial Penalty |
2313.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
2 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute. There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained. A) Spray Booth - On or about September 17, 2019, the average air speed over the open face of the spray booth was approximately 78 feet per minute. B) Spray Booth - On or about September 17, 2019, there were no manometers, gauges, or other devices installed to indicate that the required air speed was maintained. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100134 C01 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2021-06-03 |
Current Penalty |
1446.0 |
Initial Penalty |
2892.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: A) Spray Booth - On or about September 17, 2019, there was no written respiratory protection program for those employees who were required to wear half-face air purifying respirators. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100134 E01 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: A) Spray Booth - On or about September 17, 2019, employees who were required to wear half-face air purifying respirators had not been provided with medical evaluations. |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100134 H02 I |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-02-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: A) Spray Booth - On or about September 17, 2019, 3M half-face APRs were stored by hanging them from a short wall. They were coated in a thin layer of dust. |
|
Citation ID |
01002D |
Citaton Type |
Serious |
Standard Cited |
19100134 K |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary: A) Spray Booth - On or about September 17, 2019 employees who were required to wear air purifying respirators were not provided with training. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2021-06-03 |
Current Penalty |
867.5 |
Initial Penalty |
1735.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: A) Spray Booth - On or about September 17, 2019, the employer did not develop a written hazard communication program for each hazardous chemical, including but not limited to: Standard Lacquer Thinner C16036, CLAWLOCK Catalyzed Primer/Undercoater W3709, Care Catalyst C1491, DURAVAR PLUS Catalyzed Finish Satin 35 C14214, and MAGNAMAX Precatalyzed Lacquer White/Opaque Base Satin W29714. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): A) Spray Booth - On or about September 17, 2019, the employer did not maintain safety data sheets for each hazardous chemical, including but not limited to: Standard Lacquer Thinner C16036, CLAWLOCK Catalyzed Primer/Undercoater W3709, Care Catalyst C1491, DURAVAR PLUS Catalyzed Finish Satin 35 C14214, and MAGNAMAX Precatalyzed Lacquer White/Opaque Base Satin W29714. |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: A) Spray Booth - On or about September 17, 2019, the employer did not train employees on the hazards of each hazardous chemical, including but not limited to: Standard Lacquer Thinner C16036, CLAWLOCK Catalyzed Primer/Undercoater W3709, Care Catalyst C1491, DURAVAR PLUS Catalyzed Finish Satin 35 C14214, and MAGNAMAX Precatalyzed Lacquer White/Opaque Base Satin W29714. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100107 B03 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-02-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.107(b)(3): The floor surface of a spray booth and operator's working area, if combustible, was not covered with noncombustible material of such character as to facilitate the safe cleaning and removal of residues: A) Spray Booth - On or about September 17, 2019, the floor was covered in cardboard, which would be a combustible material. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100134 F02 |
Issuance Date |
2020-01-31 |
Abatement Due Date |
2020-03-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2021-03-25 |
Final Order |
2021-06-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: A) Spray Booth - On or about September 17, 2019, employees who were required to wear half-face air purifying respirators had not been fit tested. |
|
|