Search icon

TYSON 1022 LLC

Company Details

Name: TYSON 1022 LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 23 Feb 2006 (19 years ago)
Entity Number: 3324439
ZIP code: 10607
County: Westchester
Place of Formation: New York
Address: 24 TARRYTOWN RD, WHITE PLAINS, NY, United States, 10607

DOS Process Agent

Name Role Address
C/O ERNEST TARTAGLIONE DOS Process Agent 24 TARRYTOWN RD, WHITE PLAINS, NY, United States, 10607

Filings

Filing Number Date Filed Type Effective Date
220202002335 2022-02-02 BIENNIAL STATEMENT 2022-02-02
130711000771 2013-07-11 CERTIFICATE OF AMENDMENT 2013-07-11
060518000716 2006-05-18 AFFIDAVIT OF PUBLICATION 2006-05-18
060518000726 2006-05-18 AFFIDAVIT OF PUBLICATION 2006-05-18
060223000376 2006-02-23 ARTICLES OF ORGANIZATION 2006-02-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340642065 0216000 2015-05-13 1 TARRYTOWN RD., WHITE PLAINS, NY, 10607
Inspection Type Unprog Other
Scope Partial
Safety/Health Safety
Close Conference 2015-05-13
Emphasis L: FALL
Case Closed 2017-01-23

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 1040.0
Initial Penalty 1600.0
Final Order 2015-06-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Each scaffold and scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. North scaffold sections a) An employee gained access to and worked on a scaffold level with a section made out of a single plank resting on scaffold support on one side and a fiber-glass ladder on the other; on or about 05-13-2015.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19260451 A06
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-05
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person and were not constructed and loaded in accordance with that design: North scaffold sections a) An employee was working on a scaffold that was not designed or erected under the supervision of a qualified person; on or about 05-13-2015.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-05
Nr Instances 7
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports North and West scaffold sections a) An employee was working and walking on a scaffold level with incomplete planking; on or about 05-13-2015.
Citation ID 01001D
Citaton Type Serious
Standard Cited 19260451 B07
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-05
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(7): On scaffolds where platforms are overlapped to create a long platform, the overlap did not occur only over supports: West scaffold sections a) An employee was working and walking on a scaffold with a section where planks overlapped on two pieces of 2x4 instead of resting on the scaffold support; on or about 05-13-2015.
Citation ID 01001E
Citaton Type Serious
Standard Cited 19260451 C02
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-05
Nr Instances 10
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. North and West scaffold sections a) An employee was working and walking on a scaffold with frame resting directly on the ground without base plates or casters; on or about 05-13-2015.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-05-27
Abatement Due Date 2015-06-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-06-05
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) Job-site a) The employer did not have a written Hazard Communication for the protection of the employees using stucco (Enermix manufactured by Energex, an irritant); on or about 05-13-2015.

Date of last update: 28 Mar 2025

Sources: New York Secretary of State